  • Page 2 – MEASURE THE INSTALLATION
  • Page 3 – INSTALL THE WIRING
  • Page 5 – INSTALL THE HOOD; NON-DUCT KIT MODEL RKE58 CONTENTS
  • Page 7 – OPERATION
  • Page 8 – CLEANING & MAINTENANCE
  • Page 10 – LIRE CES DIRECTIVES ET LES CONSERVER; Installateur : Veuillez remettre ce; AVERTISSEMENT
  • Page 12 – INSTALLATION DU CÂBLAGE
  • Page 14 – INSTALLATION DE LA HOTTE; CONTENU DE L’ENSEMBLE MODÈLE RKE58
  • Page 16 – FONCTIONNEMENT
  • Page 17 – NETTOYAGE ET ENTRETIEN
  • Page 19 – LEA Y CONSERVE ESTAS INSTRUCCIONES; ADVERTENCIA; Aviso al instalador: Deje este manual con
  • Page 20 – INSTALE LOS CONDUCTOS; MIDA LA INSTALACIÓN
  • Page 21 – INSTALE EL CABLEADO
  • Page 22 – INSTALE LA CAMPANA
  • Page 23 – CONTENIDO DEL KIT PARA SISTEMAS SIN
  • Page 25 – FUNCIONAMIENTO
  • Page 26 – LIMPIEZA Y MANTENIMIENTO
Loading the manual

MODELS EW5830SS • EW5836SS

Page 1

Chimney
Range Hood

READ AND SAVE THESE INSTRUCTIONS

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY

TO PERSON(S) OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer. If

you have questions, contact the manufacturer at the address or

telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service panel

and lock service disconnecting means to prevent power from being

switch on accidentally. When the service disconnecting means

cannot be locked, securely fasten a prominent warning device,

such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by qualified

personnel in accordance with all applicable codes and standards,

including fire-rated construction codes and standards.

4. Sufficient air is needed for proper combustion and exhausting

of gases through the flue (chimney) of fuel burning equipment to

prevent back drafting. Follow the heating equipment manufacturer’s

guideline and safety standards such as those published by the

National Fire Protection Association (NFPA), and the American

Society for Heating, Refrigeration and Air Conditioning Engineers

(ASHRAE), and the local code authorities.

5. This product may have sharp edges. Be careful to avoid cuts and

abrasions during installation and cleaning.

6. When cutting or drilling into wall or ceiling, do not damage electrical

wiring and other hidden utilities.

7. Ducted fans must always be vented to the outdoors.
8. Use only metal ductwork.
9. Do not use this unit with any other solid-state speed control device.
10. Do not operate any fan with a damaged cord or plug. Discard fan or

return to an authorized service facility for examination and/or repair.

11. GROUNDING INSTRUCTION: The appliance must be grounded.

In the event of an electrical short circuit, grounding reduces the risk

of electric shock by providing an escape wire for the electric current.

The appliance is equipped with a cord having a grounding wire with

a grounding plug. The plug must be plugged into an outlet that is

properly installed and grounded. WARNING: Improper grounding

can result in a risk of electric shock. Consult a qualified electrician

if the grounding instructions are not completely understood, or if

doubt exists as to whether the appliance is properly grounded. Do

not use an extension cord. If the power supply cord is too short,

have a qualified electrician install an outlet near the appliance.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

a) Never leave surface units unattended at high settings. Boilovers

cause smoking and greasy spillovers that may ignite. Heat oils

slowly on low or medium settings.

b) Always turn hood ON when cooking at high heat or when flambéing

food (i.e. Crêpes Suzette, Cherries Jubilee, Peppercorn Beef

Flambé).

c) Clean ventilating fans frequently. Grease should not be allowed to

accumulate on fan or filters.

d) Use proper pan size. Always use cookware appropriate for the size

of the surface element.

1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust hazardous

or explosive materials and vapors.

3. To avoid motor bearing damage and noisy and/or unbalanced

impeller, keep drywall spray, construction dust, etc. off power unit.

4. Your hood motor has a thermal overload which will automatically

shut off the motor if it becomes overheated. The motor will restart

when it will cool down. If the motor continues to shut off and

restart, have the hood serviced.

5. The bottom of the hood MUST NOT BE LESS than 24” and

recommended at a maximum of 36” above cooktop for best

capture of cooking impurities.

6. Two installers are recommended because of the size of this

hood.

7. To reduce risk of fire and to properly exhaust air, be sure to duct

air outside. Do not exhaust air into spaces within walls or ceilings

or into attics, crawl spaces, or garages.

8. Be careful when installing the decorative flue and hood, they may

have sharp edges.

9. This hood is not intended to be used as a shelf.
10. Please read specification label on product for further information

and requirements.

Installer: Leave this manual

with the homeowner.

Homeowner: Operation and Maintenance

instructions on pages 7 & 8.

WARNING

CAUTION

FOR DOMESTIC COOKING ONLY

WARNING

Register your product online at: www.broan.com

TO REDUCE THE RISK OF INJURY TO PERSON(S) IN THE EVENT

OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:

1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal

tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS.

IF THE FLAMES DO NOT GO OUT IMMEDIATELY, EVACUATE

AND CALL THE FIRE DEPARTMENT.

2. NEVER PICK UP A FLAMING PAN – You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels – a violent

steam explosion will result.

4. Use an extinguisher ONLY if:

A. You know you have a Class ABC extinguisher, and you

know how to operate it.

B. The fire is small and contained in the area where it started.

C. The fire department is being called.

D. You can fight the fire with your back to an exit.

* Based on “Kitchen Fire Safety Tips” published by NFPA

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Broan EW5830SS

Summary

Page 2 - MEASURE THE INSTALLATION

MODELS EW5830SS • EW5836SS Page 2 INSTALL THE DUCTWORK (Ducted Hoods Only) 1. Decide where the ductwork will run between the hood and the outside. 2. A straight, short duct run will allow the hood to perform most efficiently. 3. Long duct runs, elbows and transitions will reduce the performance of t...

Page 3 - INSTALL THE WIRING

MODELS EW5830SS • EW5836SS Page 3 INSTALL THE WIRING INSTALL THE HOOD MOUNTING SUPPORT 1. Construct wood wall framing that is flush with interior surface of wall studs. Make sure the framing is centered over installation location. NOTE Hood distance above cooktop is: Minimum 24”, Maximum 36”. 9-ft. ...

Page 5 - INSTALL THE HOOD; NON-DUCT KIT MODEL RKE58 CONTENTS

MODELS EW5830SS • EW5836SS Page 5 INSTALL THE HOOD (Non-Ducted Hoods Only) NON-DUCT KIT MODEL RKE58 CONTENTS 10. Slide the upper decorative flue section into the lower decorative flue section. NOTE For ducted applications, the louvers on the upper flue should be hidden by positioning the louvers dow...

Other Broan Models