MODEL • 114

®

Page 1

WARNING

WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1. All electrical work must be done in accordance with local and/

or National Electrical Code as applicable. For safety, this prod-
uct must be grounded. If you are unfamiliar with methods of
installing electrical wiring, secure the services of a qualified elec-
trician.

2. Turn off power at service entrance before installing wiring, ser-

vicing, or cleaning this product.

3. Do not install heater upside down or sideways. Heater must be

located in the horizontal position.

4. Do not recess louvered face of the heater more than three inches

from the vertical face of any overhang (cabinet).

5. Do not locate heater behind doors, furniture, etc., where the air

flow to the unit will be restricted.

6. To avoid electrical shock; do not install heater within arm’s length

of tub or shower enclosure.

7. To avoid motor bearing damage and noisy and/or unbalanced

impellers, keep drywall spray, construction dust, etc., off power
unit.

8. Provide this heater with a separate electrical circuit following

directions under “Wire the Heater” section.

9. This product is equipped with a thermostat which may start it

automatically. Turn off power at service entrance before clean-
ing or servicing.

10. This heater includes a visual alarm to warn that parts are get-

ting excessively hot. If the alarm lights are activated, immedi-
ately turn the heater off and inspect for any objects on or adja-
cent to the heater that may cause high temperatures.

11. Please read specification label on product for further informa-

tion and requirements.

KICKSPACE
HEATER

Factory Wired 240/208 V.A.C.

READ AND SAVE THESE INSTRUCTIONS

VOLTS

WATTS

AMPS

BTU/HR

240

1500

6.3

5120

208

1125

5.4

3840

120*

1500

12.5

5120

120*

750

6.3

2560

PLAN THE INSTALLATION

This heater is designed for installation in an enclosed space such
as under a counter or kickspace to provide warm, gentle heat at the
floor level. Reread Safety Notes 3 through 8 for guidelines in plan-
ning the installation.
The Model 114 is factory wired for 240/208 V.A.C. operation. It of-
fers a choice of heat outputs and can be internally connected for
multiple wattages at different voltages shown in the table below.

All ratings are 1-Phase, 60 Hertz.
*See “FIELD CONVERSION TO 120 V.A.C.” section.

INSTALL THE HEATER

1. Mark the intended mounting location in the base plate under

the counter or kickspace, and remove required material to pro-
vide for easy insertion and removal of the heater cabinet.

2. The unit will be secured in place with screws through the side

angle support brackets. Provide adequate material behind side
angle support for secure mounting.

SIDE

ANGLE SUPPORT

BRACKETS

Installer: Leave this manual with the homeowner.

Homeowner: Use and Care information on page 3.