Broan 336 - Manual
The installation manual for the Broan Elite Model 336 exterior-mounted blower covers essential setup procedures, safety precautions, and technical requirements for roof or wall installations. Key topics include electrical wiring diagrams (such as black-to-black, white-to-blue connections), mechanical mounting steps like securing components with screws and sealing openings, and performance considerations such as ensuring free damper operation. The document also addresses maintenance tasks like cleaning and motor lubrication, alongside specifications like CFM ratings and duct size compatibility for proper ventilation systems.
Table of Contents:
- Page 1 – Installation and Safety for Exterior Mounted Blower
- Page 2 – Preparation for Mounting Locations
- Page 3 – Blower Installation Procedures and Wiring
- Page 4 – Service Parts and Warranty Information
- Page 5 – Outdoor Range Hood Fan Installation
- Page 6 – Mounting Procedure for Ventilators
- Page 7 – Ceiling Fan Installation Details
- Page 8 – Service Parts Assembly and Maintenance
- Page 9 – Exhaust Fan Specifications and Safety
- Page 10 – Preparation for Ceiling and Wall Mounting
- Page 11 – Wiring Instructions for Fan Installation
- Page 12 – Service Parts and Care Information
READ AND SAVE THESE INSTRUCTIONS
MODEL 336
EXTERIOR MOUNTED BLOWER
FOR USE WITH RANGEMASTER 60000 OR RM60000 SERIES OR 64000 SERIES RANGE HOODS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1.
Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at the
address or phone number listed in the warranty.
2.
Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3.
Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4.
Sufficient air is needed for proper combustion and exhaust-
ing of gases through the flue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the heating equip-
ment manufacturer's guideline and safety standards such as
those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive material and vapors.
2. To avoid motor bearing damage and noisy and/or unbal-
anced impellers, keep drywall spray, construction dust, etc.
off power unit.
3. Please read specification label on product for further informa-
tion and requirements.
4. Electrical circuit, including speed control, (if used), must be
rated 6 AMPS minimum.
MODEL
VOLTS
AMPS
CFM
DUCT SIZE
336
120
4.3
1500
10" DIA.
SPECIFICATIONS
INSTALLER: Leave This Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 4
MODEL 336
EXTERIOR BLOWER
WALL HOOD
CANOPY
(island canopy
available)
10" ROUND
DUCT
SOFFIT
ROUGH-IN
PLATE
24" or 27"
18"
DUCT
OPENING
COVER PLATE
MODEL
336
EXTERIOR
BLOWER
WALL HOOD
CANOPY
(island canopy
available)
10" ROUND DUCT
SOFFIT
ROUGH-IN
PLATE
24" or 27"
18"
10" ROUND ELBOW
DUCT
OPENING
COVER PLATE
TYPICAL ROOF MOUNTED INSTALLATION
(Vertical discharge)
TYPICAL WALL MOUNTED INSTALLATION
(Vertical discharge - elbow to horizontal)
WARNING
5. When cutting or drilling into wall, or ceiling, do not damage
electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
MODEL 335
EXTERIOR
BLOWER
WALL HOOD
CANOPY
(island canopy
available)
10" ROUND DUCT
SOFFIT
ROUGH-IN
PLATE
24" or 27"
18"
DUCT
OPENING
COVER
PLATE
PLAN THE INSTALLATION
1.
Locate the blower so the length of the duct run and number
of elbows needed are kept to a minimum.
ALL INSTALLATIONS
TYPICAL WALL MOUNTED INSTALLATION
(Horizontal discharge)
2.
Where possible, blower should be centered between wall
studs or roof rafters.
3.
Avoid pipes, wires, or other ductwork that may be running
through the wall.
NOTE: Horizontal discharge requires relocation of the duct
opening cover plate. See hood manual for instructions.
MODEL
336
EXTERIOR
BLOWER
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Was this manual helpful?
About this manual
- Brand
- Broan
- Model
- 336
- Document type
- Manual
- Language(s)
- English, Spanish, French
- Pages
- 12
- File size
- 376.5 KB
- Format
Other Manuals for Broan 336
Summary
Installation and safety instructions, specifications, and diagrams for roof and wall-mounted installations of the exterior mounted blower.
Instructions for preparing installation locations, including specific measurements, hole sizes, and steps for marking and cutting openings in roofing materials and wall siding.
Step-by-step procedures for roof and wall installations, detailing electrical wiring connections (black to black, white to blue, grounding to screw), mechanical securing methods, and safety notes regarding damper operation.