INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
Wall Heaters
9810WH, 9815WH SERIES
FIGURE 2
SAFETY INSTRUCTIONS
•
Carefully read all instructions and product labels before beginning
installation.
•
Only mount the heater in a vertical position.
•
Mount the heater at least 6” above the finished floor.
•
Do not mount the heater over a bathtub or in a shower stall enclosure.
•
When mounted, the heater should not be closer than 12” to an
adjacent wall.
•
Do not block the wall heater — i.e., by mounting under a towel rack,
behind a door, etc.
ELECTRICAL SPECIFICATIONS
NOTE: See wiring label on heater housing. The heater may be wired
for either 120V or 240V operation and requires a separate circuit.
UNIT DIMENSIONS
Housing:
12
1
/
2
” high x 10
1
/
2
” wide x 3
3
/
8
” deep.
Grille:
14
3
/
4
” high x 11
” wide x 1” deep.
Wall Cutout:
12
5
/
8
” high x 10
5
/
8
” wide.
MOUNTING THE HOUSING
(New Construction)
Refer to Figure 1.
1. Choose heater location.
Make sure the heater will not be mounted
closer than 12” from a vertical surface or 6” from
the floor.
2. Using nails or screws, mount one side of housing to wall stud. The
flange must be flush to the stud.
3. Run wiring from circuit breaker or fuse box to heater location.
4. Install box connector into wiring entrance hole in housing’s junction
box.
5. Pull wiring through entrance hole and secure cable to box connector.
Allow 6” of wiring to make connections.
6. Finished wall opening should be 12
5
/
8
” high x 10
5
/
8
” wide.
JUNCTION BOX
ROUGH-IN FRAME
WALL
CUTOUT
WALL STUDS
←
10
5
/
8
”
→
←
12
5
/
8
”
→
FIGURE 1
EXISTING
CONSTRUCTION
NEW CONSTRUCTION
MOUNTING THE HOUSING
(Existing Construction)
1. Choose heater location. Make sure the heater will not be mounted closer than 12”
from a vertical surface or 6” from the floor.
2.
Refer to Figure 2.
Make wall cutout next to a wall stud. Cutout size: 12
5
/
8
” high x
10
5
/
8
” wide.with frame.)
3. Run wiring from circuit breaker or fuse box to heater location.
4. Install box connector into wiring entrance hole in housing’s junction box.
5. Pull wiring through cutout and secure cable to box connector. Allow 6” of wiring to
make connections.
6.
Refer to Figure 3.
Insert TOP of housing into cutout first so that box connector clears
the wall. Then, insert bottom of housing into cutout.
The flange must be flush with
the wall.
7.
Use nails or screws to mount one side of housing to wall stud.
FIGURE 3
WALL STUDS
JUNCTION BOX
HEATER ASSMBLY
FLANGE
MOUNTING
HOLES
ROUGH-IN
BOX
“B” UNIT MOUNTING HOLE
- TOP AND BOTTOM
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
WIRING CONNECTIONS All wiring must comply with local codes and unit must be properly grounded. 1. While making wiring connections, support the heater assembly on the bottom of the rough-in frame. 2. For 120 Volt operation, make wiring connections as shown in Figure 4. 3. For 240 Volt operation, make...
INSTRUCCIONES DE INSTALACIÓN ¡LEA Y CONSERVE ESTAS INSTRUCCIONES! Calefactores de pared SERIES 9810WH, 9815WH FIGURA 2 INSTRUCCIONES DE SEGURIDAD • Lea detenidamente todas las instrucciones y etiquetas del producto antes de comenzar la instalación. • El calefactor puede instalarse únicamente en posi...
CONEXIONES DE LOS CABLES Todo el cableado debe cumplir con los códigos locales y la unidad debe estar puesta a tierra correctamente. 1. Al hacer las conexiones eléctricas, apoye el montaje del calefactor en la parte inferior de la armazón empotrada. 2. Para el funcionamiento con 120 V, haga las cone...