Page 4 - TABLE OF CONTENTS
TABLE OF CONTENTS (continued) ii Pump Parts Only PAGE E − 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PUMP AND SEAL DISASSEMBLY AND REASSEMBLY PAGE E − 6 . . . . . . . . . . . . . . . . . . . . . . . . . Suction Check Valve Disassem...
Page 5 - INTRODUCTION; The Gorman-Rupp Company; NOTE
10 SERIES OM−05463 PAGE I − 1 INTRODUCTION INTRODUCTION Thank You for purchasing a Gorman-Rupp pump.Read this manual carefully to learn how to safelyinstall and operate your pump. Failure to do socould result in personal injury or damage to thepump. This Installation, Operation, and Mainte-nance man...
Page 6 - SAFETY − SECTION A; Shut down the engine and take
10 SERIES OM−05463 PAGE A − 1 SAFETY SAFETY − SECTION A This information applies to 10 Series en-gine driven pumps. Refer to the manualaccompanying the engine before at-tempting to begin operation. Because pump installations are seldomidentical, this manual cannot possiblyprovide detailed instructio...
Page 8 - INSTALLATION − SECTION B; PREINSTALLATION INSPECTION
10 SERIES OM−05463 PAGE B − 1 INSTALLATION INSTALLATION − SECTION B Review all SAFETY information in Section A. Since pump installations are seldom identical, thissection offers only general recommendations andpractices required to inspect, position, and ar-range the pump and piping. Most of the inf...
Page 10 - SUCTION LINES
10 SERIES OM−05463 PAGE B − 3 INSTALLATION forced type to prevent collapse under suction. Us-ing piping couplings in suction lines is not recom-mended. Line Configuration Keep suction and discharge lines as straight aspossible to minimize friction losses. Make mini-mum use of elbows and fittings, wh...
Page 11 - Siphoning
OM−05463 10 SERIES PAGE B − 4 INSTALLATION If it is necessary to position inflow close to the suc- tion inlet, install a baffle between the inflow and the suction inlet at a distance 1-1/2 times the diameter of the suction pipe. The baffle will allow entrained air to escape from the liquid before it...
Page 13 - OPERATION − SECTION C; PRIMING
OM−05463 10 SERIES OPERATION PAGE C − 1 OPERATION − SECTION C Review all SAFETY information in Section A.Follow the instructions on all tags, labels anddecals attached to the pump. This pump is designed to handle dirtywater containing specified entrainedsolids. Do not attempt to pump volatile,corros...
Page 14 - STOPPING
OM−05463 10 SERIES OPERATION PAGE C − 2 line. Air from the suction line will be dischargedthrough the bypass line back to the wet well duringthe priming cycle. When the pump is fully primedand liquid is flowing steadily from the bypass line,open the discharge throttling valve. Liquid will thencontin...
Page 16 - TROUBLESHOOTING − SECTION D; Allow the pump to completely cool if
TROUBLE POSSIBLE CAUSE PROBABLE REMEDY PUMP FAILS TOPRIME Strainer clogged. Check strainer and clean if neces-sary. Suction lift or discharge head too high. Check piping installation and installbypass line if needed. See INSTAL- LATION . Leaking or worn seal or pump gasket. Check pump vacuum. Replac...
Page 18 - PREVENTIVE MAINTENANCE; Preventive Maintenance Schedule
OM−05463 10 SERIES TROUBLESHOOTING PAGE D − 3 PREVENTIVE MAINTENANCE Since pump applications are seldom identical, andpump wear is directly affected by such things asthe abrasive qualities, pressure and temperatureof the liquid being pumped, this section is intendedonly to provide general recommenda...
Page 19 - PAGE E − 1; PUMP MAINTENANCE AND REPAIR - SECTION E; STANDARD PERFORMANCE FOR PUMP MODELS 13D1−19
10 SERIES OM−05463 MAINTENANCE & REPAIR PAGE E − 1 PUMP MAINTENANCE AND REPAIR - SECTION E MAINTENANCE AND REPAIR OF THE WEARING PARTS OF THE PUMP WILL MAINTAIN PEAKOPERATING PERFORMANCE. STANDARD PERFORMANCE FOR PUMP MODELS 13D1−19 Based on 70 _ F (21 _ C) clear water at sea level with minimum ...
Page 20 - PAGE E − 2; SECTION DRAWING
10 SERIES OM−05463 MAINTENANCE & REPAIR PAGE E − 2 SECTION DRAWING PARTS PAGE Figure 1. Pump Model 13D1−19
Page 21 - PAGE E − 3; PARTS LIST; NOT
10 SERIES OM−05463 MAINTENANCE & REPAIR PAGE E − 3 PARTS LIST Pump Models 13D1−19 (From S/N 1259620 up) If your pump serial number is followed by an N", your pump is NOT a standard production model. Contact the Gorman-Rupp Company to verify part numbers. ITEM NO. PART NAME PART NUMBER MAT’LC...
Page 22 - PAGE E − 4
10 SERIES OM−05463 MAINTENANCE & REPAIR PAGE E − 4 SECTION DRAWING Figure 2. 13D1−(19) Pump Parts Only
Page 23 - PAGE E − 5
ITEM NO. PART NAME PART NUMBER MAT’LCODE QTY ITEM NO. PART NAME PART NUMBER MAT’LCODE QTY 10 SERIES OM−05463 MAINTENANCE & REPAIR PAGE E − 5 PARTS LIST 13D1−(19) Pump Parts Only 1 PUMP CASING 13304 13040 1 2 IMPELLER 13303H 11060 1 3 SEAL ASSY 25285−855 −−− 1 4 IMP ADJ SHIM SET 2X 17090 REF 5 SP...
Page 24 - If no further disassembly is required, see
10 SERIES OM−05463 MAINTENANCE & REPAIR PAGE E − 6 PUMP AND SEAL DISASSEMBLYAND REASSEMBLY Review all SAFETY information in Section A. Follow the instructions on all tags, label and de-cals attached to the pump. This pump requires little service due to its rugged,minimum-maintenance design. Howe...
Page 26 - amount of oil, and apply a drop of light lubricating; use at higher operating temperatures.; Install the seal spring and spring centering washer.
10 SERIES OM−05463 MAINTENANCE & REPAIR PAGE E − 8 To ease installation of the seal, lubricate the O-rings, sleeve and bellows with water or a very small amount of oil, and apply a drop of light lubricating oil on the finished faces. Assemble the seal as fol-lows, (see Figure 3). SPRING CENTERIN...