Page 2 - SAFETY RULES; TABLE OF CONTENTS; Hazard Symbols and Meanings; SAVE THESE INSTRUCTIONS
SAFETY RULES 2 TABLE OF CONTENTS Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4Know Your Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Operation . ....
Page 3 - WARNING
SAFETY RULES 3 • This generator does not meet U. S. Coast Guard Regulation 33CFR-183 and should not be used on marine applications. • Failure to use the appropriate U. S. Coast Guard approved generator could result in death or serious injury and/orproperty damage. WARNING • When using generator for ...
Page 4 - CAUTION
SAFETY RULES 4 • DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governedspeed. • DO NOT modify generator in any way. Excessively high operating speeds increase risk of injuryand damage to generator.Excessively low speeds impose a heavy load....
Page 5 - KNOW YOUR GENERATOR; Choke Lever — Used when starting a cold engine.
KNOW YOUR GENERATOR 5 KNOW YOUR GENERATOR Read this operator’s manual and safety rules before operating your generator.Compare the illustrations with your generator, to familiarize yourself with the locations of various controls andadjustments. Save this manual for future reference. 120 Volt AC, 15 ...
Page 6 - ASSEMBLY; Remove Generator From Carton; BEFORE STARTING THE; Add Engine Oil
ASSEMBLY 6 ASSEMBLY Your generator requires some assembly and is ready foruse after it has been properly serviced with therecommended oil and fuel.If you have any problems with the assembly of yourgenerator, please call the generator helpline at1-800-743-4115. If calling for assistance, please have ...
Page 7 - OPERATION; USING THE GENERATOR; Special Requirements
OPERATION 7 USING THE GENERATOR System Ground The generator has a system ground that connects thegenerator frame components to the ground terminals onthe AC output receptacles. The system ground is connectedto the AC neutral wire (see “Equipment Description”,earlier in this manual). Special Requirem...
Page 8 - OPERATING THE; Starting the Engine
OPERATION 8 OPERATING THE GENERATOR Starting the Engine Disconnect all electrical loads from the generator. Use thefollowing start instruction steps in numerical order: 1. Make sure unit is on a level surface. IMPORTANT: Failure to start and operate unit on a levelsurface will cause the unit not to ...
Page 9 - Stopping the Engine; COLD WEATHER; Creating a Temporary Shelter
OPERATION 9 Stopping the Engine 1. Turn OFF and unplug ALL electrical loads fromgenerator panel receptacles. NEVER start or stop enginewith electrical devices plugged in and turned ON. 2. Let engine run at no-load for several minutes tostabilize internal temperatures of engine and generator. 3. Move...
Page 10 - Creating a Permanent Shelter; RECEPTACLES; Receptacle
OPERATION 10 6. Start generator as described in the section “Startingthe Engine”, then place carton over generator. Keep atleast 5 ft. (152 cm) clearance on all sides of generatorincluding overhead with shelter in place. 7. Remove shelter when temperatures are above 40°F[4°C]. 8. Turn engine OFF and...
Page 11 - Ground Fault Protection; • Push the black “Test” button. The red “Reset” button; GENERATOR ADAPTER
OPERATION 11 Ground Fault Protection The duplex receptacles are equipped with Ground FaultCircuit Interrupter (GFCI) protection. This device meetsapplicable federal, state and local codes. The generator’slocking receptacle is not protected by a GFCI. The GFCI protects against electrical shock that m...
Page 12 - GENERATOR; Capacity
OPERATION 12 DON'T OVERLOAD GENERATOR Capacity You must make sure your generator can supply enoughrated (running) and surge (starting) watts for the items youwill power at the same time. Follow these simple steps:1. Select the items you will power at the same time. 2. Total the rated (running) watts...
Page 13 - SPECIFICATIONS AND MAINTENANCE; SPECIFICATIONS
SPECIFICATIONS AND MAINTENANCE 13 SPECIFICATIONS Starting Wattage . . . . . . . . . . . . . . . . . . . . . 5,300 WattsWattage . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4,000 WattsRated AC Load Current At 120 Volts . . . . . . . . . . . . . . . . . . . . . . . 33.3 AmpsAt 240 Volts . ...
Page 14 - STORAGE; Generator Storage
STORAGE 14 STORAGE The generator should be started at least once every sevendays and allowed to run at least 30 minutes. If this cannotbe done and you must store the unit for more than 30 days,use the following guidelines to prepare it for storage. Generator Storage • Clean the generator as outlined...
Page 15 - TROUBLESHOOTING; Problem; Generator lacks power.
TROUBLESHOOTING 15 TROUBLESHOOTING Problem Cause Correction No AC output is available, butgenerator is running. 1. One of the circuit breakers is open. 2. Fault in generator. 3. Poor connection or defective cordset. 4. Connected device is bad. 1. Reset circuit breaker. 2. Contact Authorized service ...
Page 16 - NOTES
Page 17 - LIMITED WARRANTY
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC EQUIPMENT OWNER WARRANTY POLICY LIMITED WARRANTY Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the equipment that is defective in materialor workmanship or both. Transportation charges on parts s...
Page 18 - REGLAS DE SEGURIDAD; TABLA DE CONTENIDOS; Símbolos de Peligro y Significados; ADVERTENCIA; CONSERVE ESTAS INSTRUCCIONES
REGLAS DE SEGURIDAD 18 TABLA DE CONTENIDOS Reglas De Seguridad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18-20Conozca Su Generador . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Montaje . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 20 - PRECAUCIÓN
REGLAS DE SEGURIDAD 20 • NO cambie ninguna velocidad determinada. El generador suministra una frecuencia y un voltaje calificado cuando funciona a una velocidaddeterminada. • NO modifique al generador en ninguna forma. Las velocidades de operación en exceso, aumentan losriesgos de heridas y daños al...
Page 21 - CONOZCA SU GENERADOR
CONOZCA SU GENERADOR 21 CONOZCA SU GENERADOR LEA ESTE MANUAL DEL OPERARIO Y LAS REGLAS DE SEGURIDAD ANTES DE OPERAR SU GENERADOR.Compare las ilustraciones con su Generador para familiarizarse con las ubicaciones de los diferentes controles y ajustes.Conserve este manual para referencias futuras. Pal...
Page 22 - MONTAJE; Para Retirar el Generador de la Caja; ANTES DE DARLE ARRANQUE AL; Agregar Aceite al Motor; Agregue Combustible
MONTAJE 22 MONTAJE Su generador requiere de ciertos procedimientos de montaje ysolo estará listo para ser utilizado después de haberlesuministrado servicio con el combustible y aceite recomendados. Si usted tiene problemas con el montaje de su generador, porfavor llame a la línea de ayuda para gener...
Page 23 - OPERACIÓN; USO DEL GENERADOR; Tierra del Sistema; Conexión al Sistema Eléctrico de un
OPERACIÓN 23 USO DEL GENERADOR Tierra del Sistema El generador dispone de una conexión a tierra del sistema queconecta los componentes del bastidor a los terminales de tierrade los enchufes hembra de salida de CA. La tierra del sistemaestá conectada al cable de CA neutro que, a su vez, estáconectado...
Page 24 - OPERANDO EL GENERADOR; Encienda el Motor; Conexion De Cargas Electricas
OPERACIÓN 24 OPERANDO EL GENERADOR Encienda el Motor Desconecte todas las cargas eléctricas del generador. Use lassiguientes instrucciones para encender, paso por paso, en ordennumérico.1. Asegúrese de que la unidad está en una superficie plana. IMPORTANTE: Si la unidad no se arranca y utiliza en un...
Page 25 - OPERACIÓN DURANTE UN; Creación de una Estructura de Protección
OPERACIÓN 25 Parado Del Motor 1. Desconecte TODAS las cargas eléctricas de los tomaco-rrientes del panel del generador. NUNCA de arranque odetenga el motor con los dispositivos eléctricos conectadosy ENCENDIDOS. 2. Deje que el motor funcione sin cargas por algunos minutospara estabilizar las tempera...
Page 26 - RECEPTÁCULOS; Receptáculo de Seguridad
OPERACIÓN 26 7. Retire la protección cuando las temperaturas sean superioresa 4 º C (40 º F). 8. Pare el motor y déjelo enfriar durante dos (2) minutos antesde repostar combustible. Limpie el combustible que se hayapodido derramar. Creación de una Estructura de Protección Permanente 1. Construya una...
Page 27 - JUEGO DE CABLES DEL
OPERACIÓN 27 NOTA: Si el disyuntor bipolar salta, las tomas dobles sedesconectan. Use cada receptáculo para operar 120 Voltios AC, de fase sencilla, decargas de 60Hz que requieren hasta 1,800 vatios (1.8 kW) acorrientes de 15 Amperios. Use los juegos de cables que soncalificados para cargas de 125 V...
Page 28 - NO SOBRECARGUE GENERADOR; Capacidad; Control de la Energía
OPERACIÓN 28 NO SOBRECARGUE GENERADOR Capacidad Usted debe asegurarse que su generador puede proveer elsuficiente vataje calificado (cuando esté funcionando) y de carga(al encender) para los aparatos a los cuales va a proveer laenergía, al mismo tiempo. Siga estos pasos: 1. Seleccione los aparatos q...
Page 30 - ALMACENAMIENTO; Almacenando el Generador
ALMACENAMIENTO 30 ALMACENAMIENTO El generador deberá ser encendido al menos una vez cada sietedías y deberá dejarlo funcionar al menos durante 30 minutos. Sino puede hacer esto y debe almacenar la unidad por más de30 días, siga las siguientes instrucciones para preparar su unidadpara almacenamiento....
Page 31 - DIAGNOSITICOS DE AVERÍAS; Problemo
DIAGNOSITICOS DE AVERÍAS 31 DIAGNOSITICOS DE AVERÍAS Problemo Accion Causa El motor está funcionando pero noexiste salida de AC disponsible. 1. El interruptor automático de circuitoestá abierto. 2. Conexión mal o defectuosa del juegode cables. 3. El dispositivo conectado está dañado. 4. Avería en el...
Page 32 - GARANTÍA LIMITADA
POLÍTICA DE GARANTÍA PARA EL PROPIETARIO DE EQUIPOS BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC GARANTÍA LIMITADA Briggs & Stratton Power Products Group, LLC reparará o sustituirá sin cargo alguno cualquier componente del equipo que presente defectos demateriales y/o mano de obra. Los gastos...