Page 3 - able of Contents
1 SAFETY NOTICE ................................................................. 2-3 LIST OF MATERIALS ....................................................... 4 INSTALLATION Ducting Calculation Sheet ....................................... 5 Mounting Height & Clearance ............................
Page 4 - Important Safety Notice; READ AND SAVE THESE INSTRUCTIONS
Important Safety Notice READ AND SAVE THESE INSTRUCTIONS 2 www.zephyronline.com WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this u...
Page 6 - List of Materials; PARTS NOT SUPPLIED; HARDWARE PACKAGE CONTENTS; PARTS SUPPLIED
List of Materials 4 www.zephyronline.com (3) Wire Nuts (3) M4 x 1-1/2” (2) M4 x 1” (4) 3/16” x 8 (4) M3.5 x 8 PARTS NOT SUPPLIED - Ducting, conduit and all installation tools- Cable connector (if required by local codes)- Duct cover extension accessory - Z1C-00MI- Recirculating kit accessory - ZRC-0...
Page 7 - Installation –
5 Duct pieces Total Equivalent numberlength x used = 3- 1/ 4” x 10”Rect.,straight 1 Ft. x ( ) = Ft. 8” Round,straight 1 Ft. x ( ) = Ft. 3- 1/ 4” x 10”Rect. 90 0 elbow 15 Ft. x ( ) = Ft. 3- 1/ 4” x 10”Rect. 45 0 elbow 9 Ft. x ( ) = Ft. 3- 1/ 4” x 10”Rect. 90 0 flat elbow 24 Ft. x ( ) = Ft. 3- 1/ 4” x...
Page 8 - DUCTING
Installation – Mounting Height & Clearance 6 www.zephyronline.com DUCTING A minimum of 6” round duct must be used to maintain maximum air fl ow effi ciency. Always use rigid type metal ducts only. Flexible ducts could restrict air fl ow by up to 50%. Use calculation worksheet to compute total du...
Page 9 - WARNING FIRE HAZARD
7 WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal scr...
Page 10 - top of hood; front of hood; side of hood
8 www.zephyronline.com Installation – Hood Speci fi cations 23 15/16” min. ducted - 26 1/2” min. recirc. - 30” max. - 49” 10 1/2” elec. k/o 4” 8 1/2” 35 7/16” 14” 20 1/2” 6” Ø top of hood front of hood side of hood
Page 11 - Cable Lock
9 1. Measure from range top to hood bottom and mark line A. (28” minimum from range top) . 2. Plum and mark center line. 3. Mark mounting height line B. (15-3/8” from line A) 4. Mark mounting spread from C/L. (8-7/8”) 5. Fasten (2) M4 x 1-1/2” screws into studs on line B but do not tighten all the w...
Page 12 - RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED); Charcoal Filter Replacements
10 www.zephyronline.com (blower housing) Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and fi ltered by a...
Page 13 - This feature is used for programmed shut down of; ouch Controls
11 Lights On/Dim/Off 15 Min Delay Off Display (speed level, delay off, filter clean/change) Adjust 6 Speed Levels Blower On/Off 1. Blower On/Off By pressing the blower is switched on and off. When switched on, the blower starts up on speed level 3. 2. Speed Selection The 6 speed levels are selected ...
Page 14 - Charcoal Filter Change Reminder (charcoal filter, if installed); (recirculating mode) this indicates that the; Filter Replace Indicator; Set Mode
Features & Controls – Charcoal Filter Change Reminder 12 www.zephyronline.com Charcoal Filter Change Reminder (charcoal filter, if installed) When your hood is installed as a recirculating unit, it is fitted with a set of charcoal filters to purify exhaust and fumes from cooking, then re-circula...
Page 15 - Metal Filter Clean Reminder (metal mesh filter); Clean Filters
Features & Controls – Metal Mesh Filter Clean Reminder 13 Metal Filter Clean Reminder (metal mesh filter) Whether your hood is installed as an exhaust or purifying unit, a set if metal mesh filters are fitted by the factory, These metal mesh filters are intended to filter out residue from cookin...
Page 16 - Maintenance –
14 www.zephyronline.com SURFACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning it is recommended that yo...
Page 17 - Lights; of the; REPLACING LIGHT BULBS
Maintenance - Lights 15 of the REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockw...
Page 18 - roubleshooting; TROUBLESHOOTING PROCEDURES FOR MILANO WALL
16 www.zephyronline.com T roubleshooting TROUBLESHOOTING PROCEDURES FOR MILANO WALL Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector i...
Page 19 - Accessories; DESCRIPTION
List of Parts & Accessories 17 DESCRIPTION PART# Replacement Parts Light Bulb GU-10 50W (each) Z0B-0020 Metal Mesh Filter (each) 50200011 Optional Accessories Recirculating Kit ZRC-0040 Replacement Charcoal Filter Z0F-C002 Duct Cover Extension Z1C-00MI To order parts, visit us online at http://s...
Page 20 - STAPLE YOUR RECEIPT HERE; Two Year Limited Warranty for Parts:; associated with this warranty.; Warranty Exclusions:; with this warranty.; THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.; Some states or provinces do not; To Obtain Service Under Limited Warranty:; Limited Warranty; Proof of the original purchase
1-888-880-8368 STAPLE YOUR RECEIPT HERE TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) ...