Page 3 - INSTALLATION
Ta b le o f C o n te n ts 1 SAFET Y NOTICE ..............................................LIST OF MATERIALS ....................................... INSTALLATION Ducting Calculation Sheet ............................... Mounting Height and Clearance ..................... Ducting .........................
Page 4 - READ AND SAVE THESE INSTRUCTIONS
www.zephyronline.com Im p o rt an t s af et y N o ti c e 2 TO REDUC E TH E R IS K O F F IR E O R E L E C TR IC SHOC K, D O N O T USE TH IS FAN W ITH ANY S O L ID-S TATESP E E D CONTRO L D EV IC E. TO RE DUCE TH E R IS K O F F IR E, E L E C TR IC SH O C K, O R INJU R Y TO P E R SON S, O B S E RVE TH ...
Page 5 - - SMALL HARDWARE PACKET
Li s t o f M a te ri a ls 3 MODEL: COK-ExxS 1 - Hood1 - Baffle Filter (2 on 48” model)2 - 50W 120V Halogen Light Bulbs GU-102 - 40W 120V Appliance Bulbs1 - Utensil Rail2 - Telescopic Duct Covers1 - Ceiling Mounting Bracket (pre attached to duct cover)1 - Wall Mounting Bracket 1 - HARDWARE PACKET 7 -...
Page 7 - DUCTING
5 I ns ta ll a ti o n - M o unt in g H e ight & C le a ra n c e DUCTING 36" Min 96"-Max 124” Min 28"-Max 36" Min 32"-Max 52" 14 1/2" Minimum mount height between range top to hood bot-tom should be no less than 28". Maximum mount height should be no higher than 36...
Page 8 - Ducting; WARNING FIRE HAZARD; Use single wall rigid Metal ductwork only.; Some Ducting Options:
Installation - Ducting www.zephyronline.com side wall cap with gravity damper Soffit or crawl space Roof Pitch w/ Flashing & Cap 6 Soffit or crawl space External Blower External Blower WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, ...
Page 10 - ATTENTION
www.zephyronline.com In s ta lla ti o n - In te rn a l B low e r 8 The internal blower kit consists of the blowerand capacitor box with wiring. 1. Position blower as shown. 2. Att ach blower to flange as shown usingthe provided 1/2” 5x15mm screws withwashers. 3. P osition capacitor box as shown. 4. ...
Page 13 - In
11 6. Position cover onto external blowerwiring box. 7. Secure cover to box with provided screw. 8. Attach connector from external blowerwiring box to control board box connectorinside hood. 9. Attach grounding wire from external blowerwiring box to grounding screw of the junctionbox. Refer on Fig-A...
Page 14 - NI; oi
A B min 28”max 36” C/L C/L 14 1/2” Duct CoverCeiling Bracket 7 1/2” Attach screws to ceiling bracket C/L C 21” Duct Cover Ceiling Bracket www.zephyronline.com 1. Measure from cooking surface to hood bottom, level and mark line A. 2. Plum and mark center line. 3. Mark mounting height, line B (14 1/2”...
Page 17 - ouch Controls & Features; By pressing , the blower is switched On and Off.; Advance Display Functions
15 2 3 4 6 1 5 The standard Baffle Filters are required to be cleaned frequently and as recommended in order to maintain blower efficiency. If improperly maintained, residue from cooking will sift through filters and cause damage to hood blowers and other sensitive components; and possibly clog duct...
Page 18 - Filter Clean Reminder:; Clean Filters; tu
16 Filter Clean Reminder (Standard Baffle Filters fitted): A set of baffle filters are fitted by the factory. These Baffle Filters are intended to filter out residue from cooking. Theyneed not be replaced on a regular basis but are required to be kept clean. The Filter Clean Reminder function in the...
Page 19 - Baffle Filters
17 M a in te n a n c e - C le a n in g Surface Maintenance: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steelwool/scouring pads whic ii h will scrat ch and damage surface. For heavier soil use liquid degrease r. After cleaning, you ...
Page 20 - Replacing Light Bulbs:; in
18 Replacing Light Bulbs: CA UTION: Light bulbs become extremely hot when turned on. D O N OT touch bulbs until switched off and cooled. Touching hot bulbs may cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove bulb by pressing both ends of the metal retaining clip ...
Page 22 - Part Descr iption; Accessory Descr iption Part#; List of Parts and Accessories
20 www.zephyronline.com Part Descr iption Part# Halogen Bulb G U-10, 120V, 50W Z0B-0020 Incadescent Bulb T29 127V 40 W Z0B-0003 Internal Blower, 600 cfm CBI-600 External Blower, 1000 cfm CBE-1000 Duct Cover Extension Kit Z1C-00OK Accessory Descr iption Part# List of Parts and Accessories
Page 23 - Warranty; One Year Service Repair Warranty:; This Warranty will be Voided when:; Zephyr Corporation; TO OBTAIN SERVICE UNDER WARRANTY:; You must present proof of original purchase date.; TO OBTAIN SERVICE UNDER WARRANTY; or any Service Related Questions, please call:; Staple your receipt here.
www.zephyronline.com Warranty One Year Service Repair Warranty: For one year from date of original purchase, we will provide free of charge, service labor to repair any failed parts or components due to manufacturing defects. Two Years Parts Warranty: For two years from date of original purchase, we...