Page 3 - INSTALLATION; able of Contents
1 SAFETY NOTICE ................................................................. 2-3 LIST OF MATERIALS ....................................................... 4 INSTALLATION Ducting Calculation Sheet ....................................... 5 Mounting Height & Clearance ............................
Page 4 - Important Safety Notice; READ AND SAVE THESE INSTRUCTIONS
Important Safety Notice READ AND SAVE THESE INSTRUCTIONS 2 www.zephyronline.com WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this u...
Page 5 - WARNING
Important Safety Notice 3 WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. NOT FOR USE OVER AN OUTDOOR GRILL CAUTION To reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings,attics, crawl spaces or garages. OPERATION Always ...
Page 6 - List of Materials; PARTS SUPPLIED
List of Materials 4 www.zephyronline.com MODELS: AK8200AS AND AK8300ASX PARTS SUPPLIED AK8200AS AK8300ASX 1 - Power Pack 1 - Power Pack 2 - Baffl e fi lters 3 - Baffl e fi lters 2 - Halogen light bulbs (pre-installed) 4 - Halogen light bulbs (pre-installed) 1 - Dual internal blower (pre-installed) 1...
Page 8 - DUCTING
Installation – Mounting Height & Clearance 6 www.zephyronline.com DUCTING A minimum of 6” round or 3-1/4” x 10” rectangular duct must be used to maintain maximum air fl ow effi ciency for single blower and 8” round duct for dual and remote blowers. Always use rigid type metal ducts only. Flexibl...
Page 9 - WARNING FIRE HAZARD; Some Ducting Options; Installation –
7 WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only. Fasten all connections with sheet metal screws and tape all joints with certifi ed Silver Tape or Du...
Page 10 - top; front
8 www.zephyronline.com Installation – Specifi cations C L 11 7/16 ” 13/16” 2 5/8 ” 14 11/16 ” 15 13/16 ” 2 3/8 ” 14 3/4 ” 24 5/8 ” 25 15/16 ” 29 13/16 ” 4 3/4 ” 11 7/16 ” 1 5/16 ” 6 1/2 ” 1 1/2 ” C L elec. k/o AK8200AS top AK8200AS front AK8200AS/AK8300ASX side 5” 7 3/4 ” 11 7/16 ” 14 1 1 /16 ” 15 1...
Page 12 - Remove support screw from top of Power Pack
10 www.zephyronline.com Installation – Installing the Power Pack 1. Install blower into Power Pack AK8200AS - Blower is pre-installedAK8300ASX - Refer to page 11 for instructions Remove support screw from top of Power Pack before installing into cabinet. FIG 2b 2. Install 8” round adapter to top of ...
Page 13 - MULTIPLE BLOWERS ARE COMPATIBLE WITH AK8300ASX ONLY.; FOR REMOTE BLOWER PREPARATION INSTRUCTIONS TURN TO PAGE 12.; Single Blower; Dual Blower
11 MULTIPLE BLOWERS ARE COMPATIBLE WITH AK8300ASX ONLY. AK8200AS INCLUDES A 1000 CFM DUAL BLOWER ONLY. FOR REMOTE BLOWER PREPARATION INSTRUCTIONS TURN TO PAGE 12. 1. Position blower plate over bracket on inside back of hood and pivot up. Secure plate to hood with (2) 10x3/16” screws. (blower picture...
Page 15 - Features & Controls –
13 F The standard baffle filters are required to be cleaned frequently and as recommended in order to maintain blower efficiency. If improperly maintained, residue from cooking will sift through filters and cause damage to hood blowers and other sensitive components; and possible clog duct work and ...
Page 16 - Clean Filters
Features & Controls – T ouch Controls 14 www.zephyronline.com Baffle Filter Clean Reminder Whether your hood is installed as an exhaust or purifying unit, a set if baffle filters are fitted by the factory, These baffle filters are intended to filter out residue from cooking. They need not be rep...
Page 17 - REMOTE CONTROL MAINTENANCE:; Follow instructions below for replacing battery.; Blower On/Speed Selection; REMOTE CONTROL FEATURES:
15 FCC Caution: To assure continued compliance, any changes or modifi cations not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. (Example - use only shielded interface cables when connecting to computer or peripheral device. This...
Page 18 - Baffl e Filters; Replacing Baffl e Filters:
Maintenance – Cleaning and Installing Filters 16 www.zephyronline.com SURFACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/ scoring pads which will scratch and damage surface. Do not use products containing chl...
Page 19 - REPLACING LIGHT BULBS; CAUTION: Light bulb becomes extremely hot when turned on.; Maintenance –; Bottom View
17 REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not uns...
Page 20 - roubleshooting; TROUBLESHOOTING PROCEDURES FOR TORNADO II AND TORNADO III; Issue
T roubleshooting 18 www.zephyronline.com TROUBLESHOOTING PROCEDURES FOR TORNADO II AND TORNADO III Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable lock...
Page 21 - DESCRIPTION PART #; Replacement Parts; Optional Accessories; List of Parts and
19 DESCRIPTION PART # Replacement Parts Light Bulb MR16 (GU10) 35W (each) Z0B-0023 Baffl e Filter (each) 50210010 Remote Control 14000005 Optional Accessories Liner,36” (AK8200AS) AK0806AS Liner,42” (AK8200AS) AK0842AS Liner,48” (AK8300ASX) AK0848AS Liner,54” (AK8300ASX) AK0854AS Liner,60” (AK8300AS...
Page 22 - STAPLE YOUR RECEIPT HERE; Te n Ye a r L i m i t e d Wa r r a n t y f o r P a r t s :; S o m e s t a t e s o r p r o v i n c e s d o n o t; To O b t a i n S e r v i c e U n d e r L i m i t e d Wa r r a n t y :; P l e a s e c h e c k o u r w e b s i t e f o r a n y r e v i s i o n s , w w w. z e p h y r o n l i n e . c o m .; L i m i t e d Wa r r a n t y; P r o o f o f t h e o r i g i n a l p u r c h a s e
1-888-880-8368 STAPLE YOUR RECEIPT HERE TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: Z e p h y r C o r p o r a t i o n ( r e f e r r e d t o h e r e i n a s “ w e ” o r “ u s ” ) w a r r a n t s t o t h e o r i g i n a l c o n s u m e r p u r c h a s e r ( r e ...