Page 2 - Special Notices; purpose and is displayed in the format shown:; Note: Note is used to emphasize any significant information.; General Warnings and Cautions; terminal
pg. 2 of 13 P1005089 Rev. C Special Notices The following notices emphasize certain information in the guide. Each serves a special purpose and is displayed in the format shown: Note: Note is used to emphasize any significant information. Caution: Indicates information that, if not followed, can res...
Page 3 - Introduction; MM4 Mobile Mount Safety and Installation Guide
P1005089 Rev. C pg. 3 of 13 Introduction NOTE: Zebra Technologies Corporation is not liable for personal injury or damage to any equipment caused by the improper mechanical installation of this equipment or improper connection to any power source. Check with the vehicle manufacturer or dealer for in...
Page 4 - battery or an AC power source without a proper fuse.; appropriate Installation Guide
pg. 4 of 13 P1005089 Rev. C Tools Required for Installation • An electrical drill, drill bits 1/4”(6 mm))• Taps-1/4-20 and #6-32 (M6 and M3).• Common hand tools. References • The QLn Series, QL Plus Series, and P4T/RP4T User Guides • The RCLI-DC Mobile Charger Installation Guide, or • The 50W. DC/DC...
Page 5 - *Includes minimum dimension to allow access to; Mobile Mount Mechanical Installation; Mount, depending on the individual; IMPORTANT: Mount the Printer where
P1005089 Rev. C pg. 5 of 13 Figure 1 Standard Mounting Configurations ( AK18926-3 shown with QL 420. Also used with P4T)) Vertical Mounting (numbers in italics are in cm.) hEIghT “h” WIdTh “W” dEPTh “d” dEPTh W/ BIN 21.32 IN*. 11.63 IN. 8.2 IN. 11.07 IN. 54.2 CM* 29.5 CM 20.83 CM 28.1 CM horizontal ...
Page 6 - Figure 2; Minimum clearance for
pg. 6 of 13 P1005089 Rev. C QL 420 P4T QLn420 dIM. “A” 5.82 in. [14,78 cm) 5.92 in. [15,04 cm) 7.00 in. [17,78 cm] dIM “B” 2.80 in. [7,11 cm] 4.05 in. [10,28 cm] 2.75 in [6,98 cm] Figure 2 horizontal and Vertical Mounting details (QL 420 illustrated) Use a 1/4” (6 mm) drill bit to make mounting hole...
Page 7 - when using in the horizontal configuration.
P1005089 Rev. C pg. 7 of 13 11.00" 8.63" 2.01" 2.75" 1.82" 0.31" 0.31" Dia. x4 0.31" Figure 3 Mounting Bracket hole Layout (not to scale) Note that using a MM4 Mobile Mount assembly in the horizontal configuration requires leaving a minimum access for printer controls...
Page 8 - Metal Belt Clip; QL 420 Printer Preparation; docking Contacts Plug; Printer Installation; Printer Preparation
pg. 8 of 13 P1005089 Rev. C Remove Belt Clip by removing (2) screws. Remove Carrying Strap by unscrewing corner screws Replace bushings and screws after removing carrying strap. Remove Carrying strap. Metal Belt Clip Remove (2) screws Figure 5: QL 420 Printer Preparation Figure 4: QLn420 Printer Pre...
Page 9 - Installing the Printer; module; Printer Installation (; Note: For customers who have the AK18296-3 kit and want to; from terminal
P1005089 Rev. C pg. 9 of 13 Installing the Printer The QLn420, QL 420 or P4T Printer can now be installed in the Mobile Mount. QLn420: Peel adhesive backer from the (4) Foam Washers and apply to the Mounting Plate over the printer mounting holes as indicated in Figure 6. Secure the printer to the Mo...
Page 10 - continued; Attaching the Fanfold Bin; (4 p/u for QL 420 2 p/u at lower set of; of mounting holes for P4T)
pg. 10 of 13 P1005089 Rev. C continued Install the Output Cable from the DC/DC ModuleQL 420: Plug the output voltage cable from the DC/DC module into the battery pack connector of QL 420. (Note: In some installations it may be easier to plug the charger cable into the battery pack prior to securing ...
Page 11 - Final Connections; the unit to insure compliance.; DC/DC Module Installation; DC/DC Modules for use with MM4; DC/DC Module Location
P1005089 Rev. C pg. 11 of 13 Loading Media Follow the loading procedures found in the QLn Series, QL 420 or P4T User’s Guide. Note that if you are using Fanfold media, you should install the Fanfold Spacer (p/n BA16625-1) between the printer’s media supports. The Spacer is included with the MM4 Mobi...
Page 12 - Connecting a Terminal; equipment caused by improper installation to any power source.; Installation Kit
pg. 12 of 13 P1005089 Rev. C Connect the Printer QL420: Plug the output cable from the module to the battery connection on the printer. (Refer to the QL 420 User’s Manual for more information.) It may be easier to plug in the charger connector before mounting the Printer to the Mobile Mount bracket....
Page 13 - Zebra Technologies Corporation; p. 13 of 13 P1005089 rev. C; Printer Technical Support; and software utilities, go to the Zebra Web site:
Zebra Technologies Corporation 475 Half Day Road, Suite 500 Lincolnshire, IL 60069 USA T: +1 847.634.6700 or +1 800.423.0442 p. 13 of 13 P1005089 rev. C Printer Technical Support When calling with a specific problem regarding the printers used in conjunction with the MM4 Mobile Mount, please have th...