3 I N S TA L L AT I O N R E Q U I R E M E N T S IMPORTANT NOTE: This installation must becompleted by a qualified installer or Wolfauthorized service center technician. Installer: Please read the entire InstallationInstructions prior to installation. Save theseinstructions for the local inspector’s ...
Page 4 - W O L F P R O V E N T I L A T I O N; A C C E S S O R I E S; C O N S I D E R A T I O N S
4 W O L F P R O V E N T I L A T I O N H O O D L I N E R S A C C E S S O R I E S Optional acces-sories are availablethrough yourWolf dealer. Toobtain local dealerinformation, visitthe Locator sectionof our website,wolfappliance.com. I N S TA L L AT I O N C O N S I D E R A T I O N S IMPORTANT NOTE: Wo...
Page 5 - I N S T R U C T I O N S; O V E R A L L; D I M E N S I O N S; Overall Widths; Dimensions may vary to +; S P E C I F I C A T I O N S; Pro Hood Liners
5 Dimensions in parentheses are inmillimeters unless otherwise specified. I N S TA L L AT I O N I N S T R U C T I O N S O V E R A L L D I M E N S I O N S P R O H O O D L I N E R S Overall Widths 34 3 / 8 " (873), 40 3 / 8 " (1026), 46 3 / 8 " (1178), 52 3 / 8 " (1330) and 58 3 / 8 ...
Page 6 - Letters correspond to those in the illustration.; D E C O R AT I V E; H O O D S
6 W O L F P R O V E N T I L A T I O N H O O D L I N E R S I N S TA L L AT I O N S P E C I F I C A T I O N S The illustration and chart below providedimensions critical for proper installation ofthe Pro hood liner. Pro Hood Liners Model (A) (B) (C) (D) L342212 34 3 / 8 " (873) 9 3 / 8 " (238)...
Page 7 - I N S T A L L; D U C T W O R K; Ducting for Pro hood liners
7 Dimensions in parentheses are inmillimeters unless otherwise specified. 12" (305) HEIGHT OF LINER HOOD LINER DUCTWORK INSTALLATION THROUGH ROOF 10" ROUND DUCT SOFFIT OR CABINET OR DUCT COVER VERTICAL DISCHARGE ONLY FOR VENTILATION HOOD LINERS. VERTICAL DISCHARGE 22 1 / 2 " (572) DEPTH ...
Page 8 - H O O D L I N E R; P R E P A R A T I O N; Decorative; Installation cross-section
8 W O L F P R O V E N T I L A T I O N H O O D L I N E R S W A L L P R E P A R A T I O N Construct the wood wall framing flush withthe wall studs and centered in the locationthat the hood liner will be mounted. Refer to the illustrations below for the locationof mounting holes for Pro hood liners and...
Page 10 - W I R I N G; Pro hood liner wiring location
Run a 120 V AC, 15 amp circuit (minimum)power cable from the service panel to theelectrical box in the back of the hood liner. Insert the conduit through the holes in theback of the hood liner to the electrical box. Remove the electrical box cover from theback of the hood liner. Connect black wireto...
Page 11 - I N T E R N A L; B L O W E R; Internal blower installation
11 Dimensions in parentheses are inmillimeters unless otherwise specified. I N S TA L L AT I O N I N S T R U C T I O N S I N T E R N A L B L O W E R IMPORTANT NOTE: Refer to the installationinstructions provided with the internalblower for additional mounting and wiringinstructions. L B L O W E R - ...
Page 12 - A N D; R E M O T E; B L O W E R S; Dimensions for BLOWER-110IL; Liner top plate knock-outs
12 W O L F P R O V E N T I L A T I O N H O O D L I N E R S I N - L I N E A N D R E M O T E B L O W E R S B L O W E R I N S T A L L A T I O N IMPORTANT NOTE: Refer to the specificinstallation instructions provided with eachblower for additional mounting instructions. Locate the blower so that the len...
Page 13 - Dimensions for BLOWER-90REM; Dimensions for BLOWER-150REM
13 Dimensions in parentheses are inmillimeters unless otherwise specified. I N S TA L L AT I O N I N S T R U C T I O N S I N - L I N E A N D R E M O T E B L O W E R S B L O W E R W I R I N G IMPORTANT NOTE: Refer to the specificinstallation instructions provided with eachblower for additional wiring...
Page 14 - A S S E M B L I E S; F I LT E R S; Filter installation
14 B L O W E R A S S E M B L I E S Wolf Pro ventilation hood liners are shippedwithout the blower assembly. Wolf internal,in-line and remote blower assemblies areavailable as sales accessories through yourWolf dealer. IMPORTANT NOTE: Blower options vary withthe cooking surface. Use only a Wolf blowe...
Page 15 - I F Y O U N E E D; S E R V I C E; S H O O T I N G
15 C O N T A C TI N F O R M A T I O N Wolf CustomerService:800-332-9513 Website:wolfappliance.com I F Y O U N E E D S E R V I C E Maintain the quality built into your Proventilation hood liner by calling a Wolfauthorized service center. For the name and number of the Wolfauthorized service center ne...