Page 2 - TABLE OF CONTENTS; or call Toll Free
2 TABLE OF CONTENTS Unpack and Check Shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Plan Your Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 3 - Packing List; Unpack and Check Your Car ton; INSPECT SHIPMENT
3 Packing List Unpack and Check Your Car ton INSPECT SHIPMENT Your Reverse Osmosis Drinking Water System isshipped complete in one carton. Remove all items fromyour shipping carton. Check all items against the packing list below. Note anyitems lost or damaged in shipment. Note any damage to the ship...
Page 4 - Plan Your Installation; PLAN YOUR INSTALLATION; TOOLS NEEDED
4 Plan Your Installation FIG. 1 PLAN YOUR INSTALLATION It is recommended to read through the entire manualbefore beginning your installation. Follow all steps exactly.Reading this manual will also help you get all the benefitsfrom your system.Your Reverse Osmosis Drinking Water System can beinstalle...
Page 6 - Over view and Site Preparation; OVERVIEW; STEP 2; PREPARE SITE FOR INSTALLATION
6 Over view and Site Preparation OVERVIEW There are seven easy steps to installing your Drinking Water system. They are as follows: STEP 1 - Install Cold Water Supply fitting STEP 2 - Install Drain Adapter STEP 3 - Install Reverse Osmosis Assembly STEP 4 - Install Storage Tank STEP 5 - Install Rever...
Page 7 - Step 1 - Install Supply Water Fitting; Saddle Valve Connection; CHOOSE TYPE OF WATER FITTING TO INSTALL
7 Step 1 - Install Supply Water Fitting Questions? Visit www.ecodyne.org or call Toll Free 1-866-986-3223 FIG. 5 Saddle Valve Connection (Included in package) Clamp Z Nut Nut - tightenif necessary Insert Ferrule(Plastic) Use to Connect Tubing Handle Valve Clamp X Seal CHOOSE TYPE OF WATER FITTING TO...
Page 8 - Step 2 - Install RO Drain Under Sink; INTRODUCTION; • Install the Drain Adapter included with your unit; INSTALL DRAIN ADAPTER KIT; Single trap; Under The Sink Installation
8 Step 2 - Install RO Drain Under Sink FIG. 6 FIG. 7 FIG. 8 INTRODUCTION A suitable drain point is needed for the reject water fromthe Reverse Osmosis Filter. You have two options tochoose from: • Install the Drain Adapter included with your unit See Fig 6, Fig. 7, and Fig. 8. This is used in under ...
Page 9 - Step 2 - Install RO Drain In Remote Location; INSTALL A REMOTE DRAIN POINT; RED; Remote Location
9 Step 2 - Install RO Drain In Remote Location FIG. 10 FIG. 9 INSTALL A REMOTE DRAIN POINT AND AIR GAP (Remote Location) You can also run the drain tubing to an existing drain inthe house. A floor drain, laundry tub, standpipe, sump,etc. are suitable drain points. See Fig. 10. This type ofdrain is t...
Page 10 - Step 3: Install RO Filter Assembly
Page 11 - Step 4 - Install Storage Tank; INSTALL STORAGE TANK
11 FIG. 12 Step 4 - Install Storage Tank The fitting on the supply tank may need to be tightened7-8 turns to get a good seal. Do not overtighten. INSTALL STORAGE TANK 1. Apply thread sealing tape to the threads on the nipple at the top of the tank. See Fig 12. 2. Locate the tubing connector. See Fig...
Page 12 - Step 5: Install RO Faucet
12 SELECT LOCATION OF REVERSE OSMOSISFAUCET MOUNTING HOLE You will need to select the location of the ReverseOsmosis Faucet. You have three options to choose from: • Use the existing sink top hole for the spray hose or soap dispenser (Must be 1-3/8” in diameter) • Drill a new hole in the sink • Dril...
Page 14 - Step 6 - Connect Tubes; HOW TO CUT AND CONNECT THE TUBES; Cut tubes to length; Connect tubes; Disconnect Tubes
14 Cut tubing square with end of tubing round,smooth, with no cuts, nicks or flat spots. Step 6 - Connect Tubes Questions? Visit www.ecodyne.org or call Toll Free 1-866-986-3223 FIG. 20 Tube Correctly Cut Collet Collet (Depress toRemove Tubing) Tubing Fitting O-Ring Seal Collet FIG. 17 HOW TO CUT AN...
Page 15 - CONNECT YELLOW TUBE TO STORAGE TANK; Tube Connections
15 Step 6 - Connect Tubes CONNECT YELLOW TUBE TO STORAGE TANK 1. Locate the yellow tube. One end is attached to the Reverse Osmosis filter assembly. 2. Run the other end of the yellow tube to the fitting on top of the storage tank. See Fig. 22. 3. Cut tube square and to length. See Fig. 17.4. Do not...
Page 16 - SANITIZE THE SYSTEM
16 Step 7 - Sanitize, Test and Purge System SANITIZE THE SYSTEM Sanitizing is recommended immediately after installa-tion of the Reverse Osmosis system. It’s also recom-mended after servicing inner parts. It is important thatthe person installing or servicing the system haveclean hands while handlin...
Page 18 - How Your RO Water System Works; Reverse Osmosis Cartridge:
18 How Your RO Water System Works HOW YOUR REVERSE OSMOSIS SYSTEMWORKS Introduction: Your Reverse Osmosis (RO) Drinking Water System uses your household water pressure toforce water through three filters. Minerals and impuri-ties are filtered out. Delicious tasting drinking watergoes to the storage ...
Page 19 - Water Flow Description
19 How Your RO Water System Works FIG. 25 PREFILTER PRODUCT WATER STORAGE RO MEMBRANE checkvalve drain flowcontrol AUTOMATICSHUTOFF WATER IN POSTFILTER PRODUCTWATER FAUCET air gap gravity drain RED YELLOW BLUE GREEN PRODUCT WATER BLA CK WASTE WATER Water Flow Description 1. Water enters prefilter. S...
Page 20 - Maintenance; PREFILTER/POSTFILTER MAINTENANCE; REVERSE OSMOSIS CARTRIDGE REPLACEMENT
20 Maintenance PREFILTER/POSTFILTER MAINTENANCE NOTE: It is recommended to replace the battery,prefilter and postfilter cartridges at least every 6months of product water use. Replace more often ifthey begin to plug with sediments. The prefilter and postfilter are replaceable sedimentcartridges with...
Page 21 - FLOW CONTROL; CHANGE COLLET AND O-RING; CHANGE BATTERY
21 Maintenance FIG. 27 FLOW CONTROL The flow control is vital for proper operation of theReverse Osmosis membrane cartridge. See Fig. 27. Theflow control, located in the red tube at the system hous-ing, keeps water flowing through the membrane at therequired rate. This is to ensure the system produc...
Page 22 - Specifications
22 Specifications Supply water pressure limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40-100 psi (280-689 kPa)Supply water temperature limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40-100 ...
Page 23 - Warranty; General Provisions
23 Warranty ONE YEAR LIMITED WARRANTY ON REVERSE OSMOSIS DRINKING WATER SYSTEM (Except filter cartridges and R. O. membrane) Warrantor: Ecodyne Water Systems Inc., 1890 Woodlane Drive, Woodbury, MN 55125 Warrantor guarantees, to the original owner, that the Reverse Osmosis Drinking Water System, whe...
Page 24 - Troubleshooting
24 Troubleshooting Questions? Visit www.ecodyne.org or call Toll Free 1-866-986-3223 Problem: Chlorine taste and/or odor in the RO product water. Cause: The level of chlorine in your water supplyexceeds maximum limits, and hasdestroyed the Reverse Osmosis mem-brane. Correction: If the water supply c...
Page 26 - Exploded View
26 Exploded View Questions? Visit www.ecodyne.org or call Toll Free 1-866-986-3223
Page 27 - Par ts List
27 Par ts List Questions? Visit www.ecodyne.org or call Toll Free 1-866-986-3223 Key No. Part No. Description 1 9006062 Screw (2 req’d) 2 9041700 Hanger Washer (2 req’d) 3 7115432 O-ring (2 req’d) 4 7272658 Check Valve 5 7273337 Screw (6 req’d) 6 7281330 Washer (4 req’d) 7 7273345 Automatic Shut-off...