Page 2 - INSTALLATION REQUIREMENTS; Tools and Parts; Tools needed; If using a power supply cord:; Location Requirements; IMPORTANT: Observe all governing codes and ordinances.; Mobile Home - Additional Installation Requirements; Mobile home installations require:; Product Dimensions
2 INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Tools needed Parts supplied Check that all parts are included. ■ 3 - #10-32 hex nuts (attached to terminal block) ■ 3 - ...
Page 3 - Cabinet Dimensions; Electrical Requirements; Do not use an extension cord.; Electrical Connection; * The NEC calculated load is less than the total connected load; Amps
3 Cabinet Dimensions Cabinet opening dimensions shown are for 25" (64.0 cm) countertop depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop height. IMPORTANT: If installing a range hood or microwave hood combination above the range, follow the range hood or microwave hood...
Page 4 - INSTALLATION INSTRUCTIONS; Unpack Range; Remove oven racks and parts package from inside oven.; WARNING; Excessive Weight Hazard
4 The fourth (grounding) conductor must be identified by a green or green/yellow cover and the neutral conductor by a white cover. Cord should be Type SRD or SRDT with a UL listed strain relief and be at least 4 ft (1.22 m) long. The minimum conductor sized for the copper 4-wire power cord are: 40-a...
Page 5 - Install Anti-Tip Bracket; Remove the anti-tip bracket that is taped in the storage; wall or floor with the two #12 x 1; Tip Over Hazard
5 Install Anti-Tip Bracket 1. Remove the anti-tip bracket that is taped in the storage drawer. 2. Determine which mounting method to use: floor or wall. If you have a stone or masonry floor you can use the wall mounting method. 3. Determine and mark the edge of the range in the cutout space. The mou...
Page 6 - Use Phillips screwdriver to remove the terminal block cover; screw located on the back of the range.; Remove plastic tag holding three #10-32 hex nuts from the; middle post of the terminal block.; Style 1: Power supply cord strain relief; Assemble a UL listed strain relief in the opening.; Style 2: Direct wire strain relief; Power Supply Cord
6 Electrical Connection 1. Disconnect power. 2. Use Phillips screwdriver to remove the terminal block cover screw located on the back of the range. 3. Remove plastic tag holding three #10-32 hex nuts from the middle post of the terminal block. 4. Add strain relief. Style 1: Power supply cord strain ...
Page 9 - Direct Wire Installation: Copper or Aluminum Wire; Mobile homes; Bare Wire Torque Specifications; gauge copper
9 Direct Wire Installation: Copper or Aluminum Wire This range may be connected directly to the fuse disconnect or circuit breaker box. Depending on your electrical supply, make the required 3-wire or 4-wire connection. 1. Strip outer covering back 3" (7.6 cm) to expose wires. Strip the insulati...
Page 10 - Pull the conduit through the strain relief on cord/conduit plate; Wire Awg
10 6. Use ³⁄₈ " nut driver to connect the neutral (white) wire to the center terminal block post with one of the #10-32 hex nuts. 7. Connect line 1 (black) and line 2 (red) wires to the outer terminal block posts with #10-32 hex nuts. 8. Securely tighten hex nuts. 9. Replace terminal block acces...
Page 11 - If you need Assistance or Service:
11 Verify Anti-Tip Bracket Location 1. On models with a storage drawer, pull drawer open to first stop position. Lift front of drawer to clear white wheels in drawer guides. Remove drawer and set it aside on a covered surface. On models with a warming drawer, the rear leg cannot be seen by removing ...
Page 12 - Moving the Range; If removing the range is necessary for cleaning or maintenance:; look underneath the bottom of the range:; look underneath the bottom of the range:
Moving the Range When moving range, slide range onto cardboard or hardboard to avoid damaging the floor covering. If removing the range is necessary for cleaning or maintenance: For power supply cord-connected ranges: 1. Slide range forward. 2. Unplug the power supply cord. 3. Complete cleaning or m...