Page 2 - BUILT-IN CUTOUT DIMENSIONS; BUILT-IN INSULATED SLEEVE

2 BUILT-IN STRUCTURECUTOUT DIMENSIONS Side 475 675 Burner Tolerances A 31 5 ⁄ 8 ” 43 5 ⁄ 8 ” 10 3 ⁄ 4 ” B 21 1 ⁄ 8 ” 21 1 ⁄ 8 ” 4 1 ⁄ 2 ” C 25” 25” 24” WT 240 285 40 DIMENSIONS + 3 ⁄ 16 ” - 0 + 3 ⁄ 32 ” - 0 + 3 ⁄ 16 ” -0 BUILT-IN CUTOUT DIMENSIONS BUILT-IN STRUCTURESLEEVE DIMENSIONS A B C .625 TYP. ...

Page 3 - BUILT-IN SLEEVE GAS LINE; Figure 6; DANGER: Failure to follow recommended minimum; VENTILATION; Figure 7

3 BUILT-IN SLEEVE GASLINE LOCATIONS A B C Support tubes Front of sleeve Front of sleeve Plan view Right side view 475 675 Tolerances A 5.0” 5.0” B 10.1” 10.1” C 2.5” 2.5” DIMENSIONS + 1 ⁄ 16 - 1 ⁄ 16 + 1 ⁄ 16 - 1 ⁄ 16 + 1 ⁄ 32 - 1 ⁄ 32 BUILT-IN SLEEVE GAS LINE LOCATIONS The dimensions shown indicate...

Page 4 - Gas line piping; Test connections; DANGER; Do not use an open flame to check for gas

4 TYPICAL GAS SUPPLYINSTALLATION Gas line piping ■ If the length of line required does not exceed 50 feet,use a 5/8" O.D. tube. One size larger should be usedfor lengths greater than 50 feet. ■ Gas piping may be copper tubing, type K or L;polyethylene plastic tube, with a minimum wallthickness o...