Page 2 - Configuration & Ladder Logic Example
RUI/Gateway & DeviceNet TM Configuration & Ladder Logic Example Using an Allen-Bradley CompactLogix PLC Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2007 Watlow Electric Mfg Co 2 4/08 display as shown below. In this particular case, node 7 (RUI/Gateway) appears with a qu...
Page 3 - Select Register an EDS file.
RUI/Gateway & DeviceNet TM Configuration & Ladder Logic Example Using an Allen-Bradley CompactLogix PLC Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2007 Watlow Electric Mfg Co 3 4/08 6. Select Register an EDS file. 7. Register a single file and then click browse to loca...
Page 7 - unchecked
RUI/Gateway & DeviceNet TM Configuration & Ladder Logic Example Using an Allen-Bradley CompactLogix PLC Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2007 Watlow Electric Mfg Co 7 4/08 14. After the scanner recognizes the RUI/Gateway on the network it will then appear as ...
Page 8 - was not checked
RUI/Gateway & DeviceNet TM Configuration & Ladder Logic Example Using an Allen-Bradley CompactLogix PLC Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2007 Watlow Electric Mfg Co 8 4/08 15. Once the available device (RUI/Gateway in this case) is moved over to the Scanlist ...
Page 9 - Configuration of the RUI/Gateway; where on the other side of the gateway we see four EZ-
RUI/Gateway & DeviceNet TM Configuration & Ladder Logic Example Using an Allen-Bradley CompactLogix PLC Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2007 Watlow Electric Mfg Co 9 4/08 The PLC will need to be in the program or remote program mode for this to occur. When w...
Page 11 - Configuring the DeviceNet
RUI/Gateway & DeviceNet TM Configuration & Ladder Logic Example Using an Allen-Bradley CompactLogix PLC Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2007 Watlow Electric Mfg Co 11 4/08 19. The gateway instance represents the EZ-ZONE ® control, in this case, PM 1-4. The e...
Page 12 - PM controls that exist on Standard Bus.; EEPROM
RUI/Gateway & DeviceNet TM Configuration & Ladder Logic Example Using an Allen-Bradley CompactLogix PLC Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2007 Watlow Electric Mfg Co 12 4/08 22. Notice too, the slot number, in this case “1”. This is the physical slot in which ...
Page 13 - Reading and Writing to/from RUI/Gateway Using RSLogix 5000; where it will then be routed out over Standard Bus to the EZ-ZONE
RUI/Gateway & DeviceNet TM Configuration & Ladder Logic Example Using an Allen-Bradley CompactLogix PLC Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2007 Watlow Electric Mfg Co 13 4/08 Reading and Writing to/from RUI/Gateway Using RSLogix 5000 24. The rung of logic below...
Page 14 - attribute and define the source element with the new value.; With one exception
RUI/Gateway & DeviceNet TM Configuration & Ladder Logic Example Using an Allen-Bradley CompactLogix PLC Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2007 Watlow Electric Mfg Co 14 4/08 25. Notice above that there are screen shots for the configuration and communication t...
Page 15 - Default Target to Originator (T to O) Assembly
RUI/Gateway & DeviceNet TM Configuration & Ladder Logic Example Using an Allen-Bradley CompactLogix PLC Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2007 Watlow Electric Mfg Co 15 4/08 Default Target to Originator (T to O) Assembly Default Originator to Target (O to T) A...
Page 16 - with little to no programming.; Custom O to T Data Type
RUI/Gateway & DeviceNet TM Configuration & Ladder Logic Example Using an Allen-Bradley CompactLogix PLC Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2007 Watlow Electric Mfg Co 16 4/08 29. Each of the members shown above are passed implicitly to and from the gateway to t...
Page 17 - disproportionally; does not
RUI/Gateway & DeviceNet TM Configuration & Ladder Logic Example Using an Allen-Bradley CompactLogix PLC Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2007 Watlow Electric Mfg Co 17 4/08 31. Once the user defined data types have been created for the T to O and O to T assem...
Page 18 - Gateway; Gtw
RUI/Gateway & DeviceNet TM Configuration & Ladder Logic Example Using an Allen-Bradley CompactLogix PLC Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2007 Watlow Electric Mfg Co 18 4/08 transfer of data to and from the PLC and EZ-ZONE ® controllers via simple copy instruc...
Page 19 - RUI/Gateway Addressing
RUI/Gateway & DeviceNet TM Configuration & Ladder Logic Example Using an Allen-Bradley CompactLogix PLC Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2007 Watlow Electric Mfg Co 19 4/08 Device Physical Address Logical Address (Set by User) Personal Computers 0-3 1-4 RUI 4...
Page 20 - implicit assemblies to/from the PLC to the desired EZ-ZONE
RUI/Gateway & DeviceNet TM Configuration & Ladder Logic Example Using an Allen-Bradley CompactLogix PLC Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2007 Watlow Electric Mfg Co 20 4/08 37. In step 30 it was suggested that the user may want to create user defined data typ...
Page 21 - Custom T to O Assembly
RUI/Gateway & DeviceNet TM Configuration & Ladder Logic Example Using an Allen-Bradley CompactLogix PLC Watlow 1241 Bundy Blvd Winona, MN 55987 Telephone: 507-494-5656 © 2007 Watlow Electric Mfg Co 21 4/08 Custom T to O Assembly Custom O to T Assembly