Page 3 - bold type; Syntax
TVS600 & TVS600A Series Waveform Analyzers Reference 1 Quick Reference to TVS600 & TVS600A Commands This manual provides an abbreviated reference to the commands ofTVS600 and TVS600A Series Waveform Analyzers. Use thisreference to find the correct syntax for the commands. Thecommands are gro...
Page 5 - Commands; AADVance; ABORT; ABORt; ARM
Quick Reference to TVS600 & TVS600A Commands TVS600 & TVS600A Series Waveform Analyzers Reference 3 Commands Some commands in the following list apply only to TVS600Amodels; these commands appear in bold type . AADVance Commands in the [SENSe:]AADVance subsystem control howauto-advance acqui...
Page 6 - AVERage
Quick Reference to TVS600 & TVS600A Commands 4 TVS600 & TVS600A Series Waveform Analyzers Reference AVERage Commands in the [SENSe:]AVERage subsystem controlaveraging (on incoming waveforms) in the SENSe block, which occurs prior to processing of the waveforms by the CALCulateblock. AVERage ...
Page 9 - CALibration; FORMat
Quick Reference to TVS600 & TVS600A Commands TVS600 & TVS600A Series Waveform Analyzers Reference 7 CALibration Commands in the CALibration subsystem run the waveform analyzerself-calibration functions. CALibration [:ALL][?] <none> :RESults [:CODE]? <none> :VERBose? <none> ...
Page 10 - FUNCtion; INITiate
Quick Reference to TVS600 & TVS600A Commands 8 TVS600 & TVS600A Series Waveform Analyzers Reference :DINTerchange[?] <boolean> FUNCtion Commands in the [SENSe:]FUNCtion and [SENSe:]DATAsubsystems control sense functions and provide a means of accessingthe data produced by the sense fun...
Page 11 - MEMory
Quick Reference to TVS600 & TVS600A Commands TVS600 & TVS600A Series Waveform Analyzers Reference 9 :FILTer [:LPASs] [:STATe][?] <boolean> :FREQuency[?] <NRf> :IMPedance[?] <NRf> :PROBe :ATTenuation? :IDENtification? :OFFSet? :PROTection :STATe[?] <boolean> MEMory Com...
Page 12 - OUTPut
Quick Reference to TVS600 & TVS600A Commands 10 TVS600 & TVS600A Series Waveform Analyzers Reference OUTPut Commands in the OUTPut subsystem route signals to the VXIbustrigger lines and enable the probe compensation signals andreference signals. OUTPut :ECLTrg<n> [:STATE][?] <boolea...
Page 13 - STATus
Quick Reference to TVS600 & TVS600A Commands TVS600 & TVS600A Series Waveform Analyzers Reference 11 [SENSe:] Commands in the [SENse:] system appear in the references thatfollow: [SENSe:] see AADVance see AVERage see DATA see FUNCtion see ROSCillator see SWEep see VOLTage STATus Commands in ...
Page 14 - SWEep
Quick Reference to TVS600 & TVS600A Commands 12 TVS600 & TVS600A Series Waveform Analyzers Reference :QUEStionable [:EVENt]? <none> :CONDition? <none> :ENABle[?] <NRf> | <hex> :NTRansition[?] <NRf> | <hex> :PTRansition[?] <NRf> | <hex> :QENable...
Page 15 - SYSTem
Quick Reference to TVS600 & TVS600A Commands TVS600 & TVS600A Series Waveform Analyzers Reference 13 SYSTem Commands in the SYSTem subsystem program utility functions andreturn version information about the waveform analyzer. SYSTem :AUToset :VOLTage <CHAN1–CHAN4> :SWEep <CHAN1–CHAN...
Page 16 - TEST
Quick Reference to TVS600 & TVS600A Commands 14 TVS600 & TVS600A Series Waveform Analyzers Reference :ERRor [:NEXT]? <none> :ALL? <none> :CODE [:NEXT]? <none> :ALL? <none> :COUNt? <none> :PROTect[?] <boolean> :SECurity :IMMediate <none> :SET[?] <b...
Page 24 - AAMList and WMList Parameters; and; FREQuency
Quick Reference to TVS600 & TVS600A Commands 22 TVS600 & TVS600A Series Waveform Analyzers Reference AAMList and WMList Parameters The table that follows lists the measurements available as argumentsto the CALCulate<n>:AAMList[?] and :WMList[?] (see pages 4 and 5, respectively. <lis...