Page 2 - TABLE OF CONTENTS
VPX SERIES STEAMERS F25111 (March 2002) Page 2 of 20 TABLE OF CONTENTS GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installation, Operation and Cleaning . . . . . . . . . . . ...
Page 3 - GENERAL; INSTALLATION, OPERATION; TOOLS
VPX SERIES STEAMERS - GENERAL F25111 (March 2002) Page 3 of 20 GENERAL INSTALLATION, OPERATION AND CLEANING Refer to the Installation & Operation Manual forspecific instructions. NOTE: Daily cleaning is required. INTRODUCTION Features Requires no water or drain line connections(manual fill &...
Page 4 - REMOVAL AND REPLACEMENT OF PARTS; COVERS AND PANELS; COMPONENT PANEL
VPX SERIES STEAMERS - REMOVAL AND REPLACEMENT OF PARTS F25111 (March 2002) Page 4 of 20 REMOVAL AND REPLACEMENT OF PARTS COVERS AND PANELS WARNING: DISCONNECT THE ELECTRICALPOWER TO THE MACHINE AT THE MAINCIRCUIT BOX. PLACE A TAG ON THE CIRCUITBOX INDICATING THE CIRCUIT IS BEINGSERVICED. Right Side ...
Page 8 - MANUAL DRAIN VALVE
VPX SERIES STEAMERS - REMOVAL AND REPLACEMENT OF PARTS F25111 (March 2002) Page 8 of 20 A. Temporarily install a flat washer and nut on all mounting studs. Hand tighten only. B. Tighten each nut to 100 in-lb using the sequence as shown. C. Remove nut and washer from each mounting stud. D. Apply Loct...
Page 9 - DOOR
VPX SERIES STEAMERS - REMOVAL AND REPLACEMENT OF PARTS F25111 (March 2002) Page 9 of 20 5. Remove mounting nuts & washers from the rearcooking compartment support legs and removebase. 6. Remove outer nut on drain valve stem and liftoff drain handle assembly. 7. Remove manual drain valve from coo...
Page 11 - SERVICE PROCEDURES AND ADJUSTMENTS; DOOR LATCH
VPX SERIES STEAMER - SERVICE PROCEDURES AND ADJUSTMENTS F25111 (March 2002) Page 11 of 20 Latch Assembly 1. Open the door. 2. Remove screws from the top and bottom of thedoor. 3. Pull the "inner" door panel out from the doorhousing with the gasket plate and gasket stillattached. 4. Remove th...
Page 13 - TEMPERATURE CONTROL
VPX SERIES STEAMER - SERVICE PROCEDURES AND ADJUSTMENTS F25111 (March 2002) Page 13 of 20 VOLTAGE KW PER ELEMENT AMPS PER ELEMENT OHMS PER ELEMENT 1 PH 3 PH 208 3 14.4 8.3 14.4 240 3 12.5 7.2 19.2 480 3 3.6 76.8 208 5 24.0 14.0 8.70 240 5 21.0 12.0 11.5 480 5 6.0 46.0 NOTES: 1. Values in the table a...
Page 14 - ELECTRICAL OPERATION; COMPONENT FUNCTION; COMPONENT LOCATION
VPX SERIES STEAMER - ELECTRICAL OPERATION F25111 (March 2002) Page 14 of 20 ELECTRICAL OPERATION COMPONENT FUNCTION Buzzer . . . . . . . . . . . . . . . . . . Signals end of a "cook" cycle when cooking time expires. Contactor . . . . . . . . . . . . . . . Supplies line voltage to heating ele...
Page 15 - SEQUENCE OF OPERATION
VPX SERIES STEAMER - ELECTRICAL OPERATION F25111 (March 2002) Page 15 of 20 SEQUENCE OF OPERATION Wiring diagram 7264 will be used to explain theelectrical sequence of operation. Timed Cooking Mode 1. Conditions. A. Steamer connected to correct voltage andis properly grounded. B. Cooking mode switch...
Page 17 - WIRING DIAGRAMS
VPX SERIES STEAMER - ELECTRICAL OPERATION F25111 (March 2002) Page 17 of 20 WIRING DIAGRAMS 208-240V
Page 19 - TROUBLESHOOTING; SYMPTOM
VPX SERIES STEAMER - TROUBLESHOOTING F25111 (March 2002) Page 19 of 20 TROUBLESHOOTING WARNING: CERTAIN PROCEDURES IN THIS SECTION REQUIRE ELECTRICAL TESTS ORMEASUREMENTS WHILE POWER IS APPLIED TO THE MACHINE. EXERCISE EXTREME CAUTION AT ALLTIMES. IF TEST POINTS ARE NOT EASILY ACCESSIBLE, DISCONNECT...
Page 20 - CONDENSED SPARE PARTS LIST
VPX SERIES STEAMER - CONDENSED SPARE PARTS LIST F25111 (March 2002) Printed in U.S.A. CONDENSED SPARE PARTS LIST VPX3 & VPX5 PART NUMBER DESCRIPTION NOTES 844385 Door Gasket (VPX5) 844196 Door Gasket (VPX3) 843811 Door Switch 853928 Thermostat - Temperature Control 853956 Thermostat - Standby 85...