Page 2 - IMPORTANT FOR YOUR SAFETY
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -2- IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LO...
Page 3 - TABLE OF CONTENTS
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -3- TABLE OF CONTENTS IMPORTANT FOR YOUR SAFETY………………………………………. 2 INTRODUCTION…………………………………………………………… 4 GENERAL…………………………………………………………… 4 ORDERING PARTS………………………………………………… 4 FRYER CAPACITIES………………………………………………. 4 UNPACKING………………………………………...
Page 4 - INTRODUCTION; GENERAL; ORDERING PARTS; FRYER CAPACITY; UNPACKING
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -4- INTRODUCTION GENERAL Vulcan Fryers are produced with quality workmanship and material. Proper installation, usage and maintenance will result in years of satisfactory performance. Before installing the fryer, thoroughly read this m...
Page 5 - PLUS®; INSTALLATION
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -5- Check that the following have been included: Crumb Rack Basket Hanger Twin Fry Baskets (2) Tank Brush Adjustable Casters (4) two locking, two non-locking for freestanding fryers. Fryer Batteries with the KleenScreen PLUS®...
Page 6 - Location; CODES AND STANDARDS; In the United States:
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -6- Minimum clearance from noncombustible construction: 0” from the sides of the fryer 0” from the back of the fryer Between the fryer and any open-top flame units: 16” (41 cm) Allow space for servicing and operation. Location ...
Page 7 - ASSEMBLY; Vapor Removal from Cooking Equipment; GAS CONNECTION
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -7- ASSEMBLY The fryer must be restrained to prevent tipping and the splashing of hot liquid. The means of restraint may be the manner of installation, such as connection to a battery of appliances, installing the fryer in an alcove, o...
Page 8 - Prior to lighting, check all joints in the gas supply line for leaks.
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -8- Prior to lighting, check all joints in the gas supply line for leaks. Use soap and water solution. Do not use an open flame. After piping has been checked for leaks, fully purge gas pipes to remove air. GAS PRESSURES (ALL MODELS): ...
Page 9 - with the above codes.; LEVELING THE FRYER; Hot oil and parts can cause burns. Use care when operating,; OVER-TEMPERATURE SHUTDOWN
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -9- The fryer must be installed with a connector (not supplied by Vulcan) complying with the above codes. The fryer must be installed with restraining means to guard against transmission of strain to the connector. See illustration...
Page 10 - BEFORE FIRST USE
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -10- BEFORE FIRST USE Cleaning New units are wiped down at the factory to remove any visible signs of dirt, oil, grease, etc. remaining from the manufacturing process. Before any food preparation, thoroughly wash the protective oil fro...
Page 11 - LIGHTING THE PILOT
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -11- LIGHTING THE PILOT A B A Thermostat Knob B Gas Control Handle 1. Open the door. 2. Turn the thermostat to OFF (see figure below, view A). The thermostat is located behind the door. 3. Push the gas control valve knob and turn to OF...
Page 12 - TURNING ON THE FRYER; Set the temperature knob to desired temperature.; TURNING OFF THE FRYER; Fry items that are the same size to ensure equal doneness.
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -12- TURNING ON THE FRYER Set the temperature knob to desired temperature. After the set temperature has been reached, the thermostat shuts off the gas flow to burners. The pilot remains lit. The burners will cycle on and off, ma...
Page 13 - Fry Basket Capacity:; EXTENDING SHORTENING LIFE; Hot oil and hot parts can cause burns. Use care when operating,
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -13- When frying doughnuts and fritters, turn product only once during frying. When cooking French fries or onion rings, shake the basket several times. Batter-covered foods should be dropped carefully, one by one, into shortenin...
Page 14 - the drain valve all the way.; CLEANING; Clean all exterior surfaces of your fryer at least once daily.
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -14- 5. Slowly open the drain valve to allow oil to flow from the fry tank to the filter pan. Then open the drain valve all the way. 6. When fry tank is empty use the tank brush to remove any additional debris. 7. Close the drain valve...
Page 15 - BOIL OUT PROCEDURE
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -15- Use a damp cloth with warm water and a mild soap or detergent. Do not use chlorine or sulfate/sulfide cleaners. Rinse thoroughly, and then polish with a soft dry cloth. Keep the fryer exterior clean and free of accumulated g...
Page 16 - KleenScreen PLUS® Filtration System; Installation and Operational Manual
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -16- KleenScreen PLUS® Filtration System Installation and Operational Manual For GRMF Models 2GR45MF Shown GAS KleenScreen PLUS® Models: 1GR45MF ML-136785 1GR65MF ML-136786 1GR85MF ML-136787 2GR45MF ML-136417 2GR65MF ML-136418 2GR85MF ...
Page 17 - Filtering Instructions for KleenScreen PLUS® Fryers; General; The KleenScreen; Assembly; Filter Insert
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -17- Filtering Instructions for KleenScreen PLUS® Fryers General The KleenScreen PLUS® filtration system filters the oil as it is pumped back into its’ respective tank(s). Only one tank can be drained and filtered at a time. Under no c...
Page 18 - Fully assembled filter screen assembly:
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -18- Fully assembled filter screen assembly: Fig. 2 Secure Tube with Suction Tube Clip Filter Screen Lays Flat On Bottom of Filter Pan Fig. 3 Micro-Filtration Fabric Envelope Assembly: Same Suction Tube Fabric Envelope Insert (Differen...
Page 20 - Operation
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -20- Operation Hot oil and parts can cause burns. Use care when operating, cleaning and servicing the fryer. Spilling hot frying compound can cause severe burns. Do not move fryer without draining all frying compound from the tank. Nev...
Page 21 - OFF
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -21- 4. Drain the oil out of the fry tank by turning the red handle drain valve. The filter pan will begin to fill with oil. When the oil level fills half of the filter pan, pull the red handled filter lever towards you. The motor / pu...
Page 22 - the fryer oil into the filter pan.
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -22- FLUSH AND DISCARD: 1. Follow filtering instructions 1-3, however do not put oil treatment media into the fryer. Drain the fryer oil into the filter pan. 2. Attach the quick disconnect hose to the discard male quick disconnect fitt...
Page 23 - MAINTENANCE; FLUE VENT INSPECTION
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -23- THERMAL OVERLOAD PROTECTION BUTTON: The motor/pump supplied with the filtering system has a thermal overload protection circuit that senses when excess heat occurs due to filtering for long periods of time or under heavy load prio...
Page 24 - Troubleshooting Chart:; Probable
GRM SERIES GAS FRYERS VULCAN-HART F-31233 Rev. K (February 2011) -24- Troubleshooting Chart: Problem: Probable Cause: No Heat: Thermostat dial not turned on. Pilot not lit. Gas supply not turned on. Wire connections loose (call service) Wires connections need cleaning (call service) Thermopile (call...