Page 2 - UGT‐IS602R Page 2
UGT‐IS602R Page 2 Features and Benefits z PCI-Express 2.0 x 1 (Compatible with PCI-Express 1.0) z Supports communication speeds of 6.0Gbps, 3.0Gbps, and 1.5Gbps z Hot plug and Hot Swap z Support Native Command Queuing...
Page 3 - UGT‐IS602R Page 3; Specifications
UGT‐IS602R Page 3 Specifications Model: UGT-IS602R Bus interface: PCI-Express 2.0 x 1 Ports: 2 x Internal SATA 6G ports (Backward compatible with SATA 3.0Gbps & 1.5Gbps) 1 x Internal IDE/PATA port Dimension: 119 x...
Page 5 - UGT‐IS602R Page 5; Hardware Installation; Creating Virtual Disks; Configuration Wizard
UGT‐IS602R Page 5 Hardware Installation 1. Turn off the power to your computer. 2. Unplug the power cord and remove your computer’s cover. 3. Remove the slot bracket from an available PCIe slot. 4. To install the boar...
Page 6 - Figure 1 Configuration Wizard; Press; Space; the arrow keys to scroll the list of free disks.; Figure 2 Select Free Disks; UGT‐IS602R Page 6
the virtual disk. Figure 1 Configuration Wizard 2. Press Space to select/unselect a disk, as shown in Figure 2. Use the arrow keys to scroll the list of free disks. Figure 2 Select Free Disks UGT‐IS602R Page 6
Page 7 - Enter; UGT‐IS602R Page 7
Note: The 2+1 SATA 6G & PATA PCI-E COMBO HOST CARD WITH RAID supports the creation of RAID 0 and RAID 1 virtual disks comprising of exactly two SATA physical disks. PATA physical disks cannot be used to create RAID virtual disks. 3. After selecting the required disks, press Enter to continue, as...
Page 8 - Create Virtual Disk; by configuring its setting in the; Information; The controls for making selection are listed in the; Help; pane; Figure 4 Configure Virtual Disk; UGT‐IS602R Page 8
4. Create Virtual Disk by configuring its setting in the Information pane, as shown in Figure 4. The controls for making selection are listed in the Help pane when an available setting is highlighted. Figure 4 Configure Virtual Disk UGT‐IS602R ...
Page 9 - UGT‐IS602R Page 9
Note: Max size (MB) and Disk ID are properties of the virtual disk that cannot be edited. Max size (MB) in the size of the RAID virtual disk as determined by the selected RAID Level. Disk ID lists the IDs of the physical disks comprising the virtual disk. 5. RAID Level , as shown in Figure 4, is hig...
Page 10 - UGT‐IS602R Page 10
Note: The default Level is RAID 0. 7. Scroll to Stripe Size and press Enter to select. A menu pops-up, as shown in Figure 6, and lists available stripe sizes for the selected RAID level. 8. Scroll the list, as shown in Figure 6, and press Enter to select Stripe Size (32K, 64K) Figure 6 Stripe Size U...
Page 11 - UGT‐IS602R Page 11
Note: The default size is 64 KB. 9. Scroll to Gigabyte Rounding and press Enter to select. A menu pops-up, as shown in Figure 7, and lists available stripe sizes for the selected RAID level. 10. Scroll the list, as shown in Figure 7, and press Enter to select Gigabyte Rounding (None, 1G, 10G) Figure...
Page 12 - UGT‐IS602R Page 12
Note: The default setting for Gigabyte Rounding is 1G. 11. Scroll to Quick Init and press Enter to enable to disable quick initialization of the virtual disk. A menu pops-up, as shown in Figure 8, and lists available options for quick initialization of the virtual disk. 12. Scroll the list, as shown...
Page 13 - VD Name; and the Default name is cleared for a new; to confirm the selection.; Figure 9 VD Name; UGT‐IS602R Page 13
Note: The default setting for Quick Init is Yes. 13. Scroll to VD Name and the Default name is cleared for a new name, as shown in Figure 9. Type a new name and press Enter to confirm the selection. Figure 9 VD Name UGT‐IS602R ...
Page 14 - After configuring the virtual disk, scroll to; Next; to create the virtual disk.; Figure 10 Create Virtual Disk; UGT‐IS602R Page 14
14. After configuring the virtual disk, scroll to Next , as shown in Figure 10. Press Enter to create the virtual disk. Figure 10 Create Virtual Disk UGT‐IS602R Page 14
Page 15 - Yes; creation of the virtual disk. The virtual disk is now listed in the; Topology; UGT‐IS602R Page 15
15. Please Y to select Yes , as shown in Figure 11, to confirm the creation of the virtual disk. The virtual disk is now listed in the Topology pane, as shown in Figure 12. Figure 11 Create Virtual Disk Confirmation UGT‐IS602R ...
Page 16 - Figure 12 Virtual Disk in Topology Pane; UGT‐IS602R Page 16
Figure 12 Virtual Disk in Topology Pane UGT‐IS602R Page 16
Page 17 - UGT‐IS602R Page 17; Managing Virtual Disks
UGT‐IS602R Page 17 Managing Virtual Disks This section contains the following topics: z Viewing Properties of Virtual Disk z Erasing RAID Configuration Data z Rebuilding Virtual Disk z Deleting Virtual Disk Viewing Pro...
Page 18 - Erasing RAID Configuration Data; Note; UGT‐IS602R Page 18
Erasing RAID Configuration Data Note : The RAID controller stores RAID configuration data on all physical disks that are part of a virtual disk. RAID configuration data must be erased on the physical disk before it can be used with another virtual disk. 1. In the Topology pane, select Physical Disk ...
Page 19 - Figure 14 Erase RAID Configuration Data; Rebuilding Virtual Disk; WITH RAID BIOS supports manual rebuilding of RAID 1 virtual; To manually rebuild a RAID 1 virtual disk; UGT‐IS602R Page 19; Status; of a virtual disk is
Figure 14 Erase RAID Configuration Data Rebuilding Virtual Disk Note : The 2+1 SATA 6G & PATA PCI-E COMBO HOST CARD WITH RAID BIOS supports manual rebuilding of RAID 1 virtual disks. The rebuild process is both initiated and complete in the BIOS. The Marvell RAID Utility (MRU), which runs in an ...
Page 20 - UGT‐IS602R Page 20
changed from Functional to Degrade , as shown in Figure 15. Figure 15 Virtual Disk Properties: Degrade VD 2. Replace the faulty physical disk with an identical physical disk. Note: If an identical disk is unavailable, use a replacement physical disk or larger size or one with a slightly smaller size...
Page 21 - In the; Topology pane; in; Scroll to; Rebuild; and press; to configure the rebuild; Figure 17 Rebuild Virtual Disk; UGT‐IS602R Page 21
3. In the Topology pane , scroll to Virtual Disks (VD 0: New_VD in Figure 17), and press Enter to select. A menu pops-up, as shown in Figure 17 Scroll to Rebuild and press Enter to configure the rebuild process. Figure 17 Rebuild Virtual Disk UGT‐IS602R ...
Page 22 - Scroll through the list of free disk, as shown Figure 18, and press; to select or unselect a replacement physical disk.; UGT‐IS602R Page 22
4. Scroll through the list of free disk, as shown Figure 18, and press Space to select or unselect a replacement physical disk. Press Enter to continue. Figure 18 Select Replacement Disk UGT‐IS602R Page 22
Page 23 - , as shown in Figure 19, when prompted to; Figure 19 Confirm Rebuild Virtual Disk
UGT‐IS602R Page 23 5. Press Y to select Yes , as shown in Figure 19, when prompted to confirm the rebuild process. Figure 19 Confirm Rebuild Virtual Disk
Page 24 - UGT‐IS602R Page 24
6. The status of the Rebuild process is reflected in the properties of the virtual disk, as shown in Figure 20. Figure 20 Rebuild Status To pause the rebuild process 1. In the Topology pane, scroll to the partially rebuild Virtual Disk . 2. Press Enter to view available operation on Virtual Disk . U...
Page 25 - UGT‐IS602R Page 25; Deleting Virtual Disk
UGT‐IS602R Page 25 To pause the rebuild process 1. In the Topology pane, scroll to the partially rebuild Virtual Disk . 2. Press Enter to view available operation on Virtual Disk . 3. Scroll to Resume and press Enter t...
Page 26 - Note: Driver can also be found and downloaded from our website at; For Windows® XP/Server 2003; UGT‐IS602R Page 26; A new installation requires a floppy disk for the driver
Driver Installation Note: Driver can also be found and downloaded from our website at www.vantecusa.com For Windows® XP/Server 2003 UGT‐IS602R Page 26 For A New Installation A new installation requires a floppy disk fo...
Page 27 - UGT‐IS602R Page 27
UGT‐IS602R Page 27 below. 1. Follow Microsoft’s Windows installation procedure. 2. At the Windows Setup screen, press F6 to install the driver. 3. When prompted, press S to specify the location of the driver. 4. Insert...
Page 29 - UGT‐IS602R Page 29
UGT‐IS602R Page 29 below. 1. Follow Microsoft’s Windows installation procedure. 2. At the Windows Setup screen, press F6 to install the driver. 3. When prompted, press S to specify the location of the driver. 4. Insert...
Page 31 - UGT‐IS602R Page 31
UGT‐IS602R Page 31 3. Insert the CD driver bound with 2+1 SATA 6G & PATA PCI-E COMBO HOST CARD WITH RAID into your CD-ROM Drive, please select Marvell 91xx SATA 6G Controller ( D:\UGT-IS602R\XP_2003_Vista_2008_7\Fl...
Page 34 - UGT‐IS602R Page 34; To Verify Driver Installation
UGT‐IS602R Page 34 3. Type D:\UGT-IS602R\XP_2003_Vista_2008_7\Setup.exe , click OK . (Change D:\ to match your CD-ROM drive letter) 4. Follow the on-screen instructions to complete the installation. 5. Restart Windows ...
Page 35 - UGT‐IS602R Page 35
UGT‐IS602R Page 35
Page 36 - UGT‐IS602R Page 36; Warranty; The; Vantec Thermal Technologies
UGT‐IS602R Page 36 Warranty The 2+1 SATA 6G & PATA PCI-E COMBO HOST CARD WITH RAID comes with a 1 year limited warranty(90 day parts). If your unit becomes defective within that time frame, please go to www.vantecu...