Page 2 - TABLE OF CONTENTS
TABLE OF CONTENTS The serial tag is a permanently affixed sticker onwhich is recorded vital electrical and refrigeration dataabout your Traulsen product, as well as the modeland serial number. This tag is located in the upperright interior compartment on all reach-in/pass-thruand roll-in/roll-thru r...
Page 3 - II. RECEIPT INSPECTION
-2- II. RECEIPT INSPECTION All Traulsen products are factory tested for perfor-mance and are free from defects when shipped. Theutmost care has been taken in crating this product toprotect against damage in transit. All interior fittingshave been carefully secured and the legs or castersare boxed an...
Page 4 - SEALING BASE OF ROLL-IN MODELS
III. f - INSTALLING THE CONDENSATE EVAP (cont ’ d): holes on the exterior bottom towards the rear of thecabinet. Then, using the four (4) screws provided, at-tach the mounting rails to the cabinet bottom (the endflange is to be up and be facing towards the cabinetrear). Next, place the heater into t...
Page 5 - Assembly; above is required in order to per-
IV. a - CLEANING THE CONDENSER (cont’d):two screws located on both sides at the bottom of thelouver assembly (see figure 6). Once the screws areremoved, the panel can be pivoted upwards allowingfull access to the front facing condenser (see figure7). Vacuum or brush any dirt, lint or dust from thefi...
Page 7 - VII. SPECIALTY PRODUCTS - FISH FILE MODELS; However, a fish file
-6- VII. SPECIALTY PRODUCTS - FISH FILE MODELS VII. a - FISH FILE APPLICATION:Traulsen fish file models are specifically designed forthe storage of fresh fish or poultry in a moist refriger-ated environment, packed in crushed ice, thereby pre-venting dehydration and bacteria growth. For best re-sult...
Page 8 - VIII. SPECIALTY PRODUCTS - BLAST FREEZER MODELS; However, a blast freezer; The Blast Freezer Control
-7- VIII. SPECIALTY PRODUCTS - BLAST FREEZER MODELS VIII. a - BLAST FREEZER APPLICATION:The roll-in blast freezer models were specifically de-signed for batch processing, where quick freezing ofcooked product is required to help prolong shelf life. VIII. b - SPECIAL INSTALLATION NOTE:Installation sh...
Page 9 - ABRASION; IX. STAINLESS STEEL OVERVIEW
-8- TROUBLE IX. a - INTRODUCTION:Most Traulsen models are constructed with a high quality430 series, 20 gauge stainless steel exterior finish (front,sides and doors). The interior finish on these same mod-els are constructed using 300 series stainless steel. The stainless steel finish on Traulsen pr...
Page 11 - XI. TROUBLE SHOOTING GUIDE; FIND YOUR PROBLEM HERE
XI. TROUBLE SHOOTING GUIDE FIND YOUR PROBLEM HERE REMEDY 1. Condensing unit fails to start. a. Check if cord & plug has been disconnected. 2. Condensing unit operates for a. Are doors closing properly? prolonged periods or continuously. b. Dirty condenser or filter. Clean properly. c. Evaporator...
Page 12 - Quality Refrigeration; XII. WARRANTY INFORMATION; STANDARD DOMESTIC WARRANTY; will remain the responsibility of the owner.; INTERNATIONAL COMMERCIAL WARRANTY; (for Canadian warranties see domestic US warranty); dryers & refrigerant gas) which then proves to be defective.; This warranty does not apply to damage resulting from fire,; TRAULSEN
Traulsen 4401 Blue Mound Road Fort Worth, TX 76106Phone: (800) 825-8220 Fax-Svce: (817) 740-6757Website: www.traulsen.com HOURS OF OPERATION: Monday thru Friday 7:30 am - 4:30 pm CST Quality Refrigeration © 2004 Traulsen - All Rights Reserved XII. WARRANTY INFORMATION STANDARD DOMESTIC WARRANTY TRAU...