Page 2 - F down to below 41; TABLE OF CONTENTS
Thank you for your decision to purchase a Traulsen Blast Chiller. This important piece of foodsafety equipment is built to our highest standards and will provide you with years of dependableservice. However, it is important to note that although this product is designed to chill product from135 ° F ...
Page 3 - Blast Chiller Installation Checklist; BY TIME
Blast Chiller Installation Checklist Model RBC501) Insure proper clearances, no obstruction to either front louver for at least 24 ” from cabinet face. 2) Install all eight legs or casters, insuring that the unit is level for proper operation (see section III d.for more details). 3) Install the cont...
Page 4 - Blast Chiller Quick Start Checklist; For more details and/or to make use of other
Blast Chiller Quick Start Checklist Starting a Chill Cycle - All Models1) Load product into the blast chiller. Both full and partial loads are OK,but for best results evenly distribute product throughout the interiortray slides or roll-in rack. 2) Insert a food probe into the top, bottom and middle ...
Page 5 - Basic Operating Guidelines
Basic Operating Guidelines Chilling Within HACCP Guidelines1) The current FDA Food Code allows much more time for safe chillingthan 90-minutes. This actually requires two critical control points of:a) From 135 ° F to 70 ° F within two hours, then... b) From 70 ° F to below 41 ° F within four hours, ...
Page 6 - II. RECEIPT INSPECTION; s Bill Of Lading describing this. A freight claim
III. d - INSTALLING LEGS OR CASTERS (cont ’ d): box(es), it should contain either four (4) legs or casters(RBC50 x 8 or RBC100 x 4 and four bolts for each caster).WARNING: THE CABINET MUST BE BLOCKED ANDSTABLE BEFORE INSTALLING LEGS OR CASTERS.To install the legs or casters, first raise and block th...
Page 11 - CONTROL; SmartChill
VI. a - THE SMARTCHILL CONTROL - OVERVIEW:This unit is equipped with our exclusive SmartChill ® microprocessor control (Traulsen Blast Chill unitsmanufactured prior to 6/03 were equipped with theDIGITRAUL II control, please refer to owner's manualpart number 375-60180-00 for more information). The S...
Page 12 - STEP FOUR: Insert the food probes into the food product as shown in; VII. OPERATING THE BLAST CHILL CONTROL - STARTING A CHILL CYCLE; MAIN
CHILLING AIR: 14 ° F 1 41 ° F DONE 3 2 44 ° F 1:16:01 MUTE BY TEMPERATURE T Y P E : C H I L L ↓ ↓ ↓ ↓ ↓ TARGET TEMP: 37 ° F ↑ ↑ ↑ ↑ ↑ MAIN START MAIN MENU AIR 35 ° F BY TEMP BY PROD BY TIME 08:05:01 MORE MAIN MENU AIR 35 ° F BY TEMP BY PRODBY TIME 08:05:01 MORE VII. a - STARTING A CHILL CYCLE - BY T...
Page 13 - Select the
PRINTING PLEASE WAIT... VII. OPERATING THE BLAST CHILL CONTROL - STARTING A CHILL CYCLE -12- VII. a - STARTING A CHILL CYCLE - BY TEMP (cont ’ d): STEP SIX: Select the “ done ” probe(s) by pressing the button(s) to the left or right of where that number probe(s) is displayed. Removeall product assoc...
Page 14 - MUTE; F). Product which was either BLAST or SOFT; ADD 30 MINUTES: adds 30 additional minutes to the timer.
HOLDING AIR: 14 ° F 1 41 ° F 43 ° F 3 2 44 ° F 1:16:01 MUTE MAIN MENU AIR 35 ° F BY TEMP BY PRODBY TIME 08:05:01 MORE VII. b - STARTING A CHILL CYCLE - BY TIME:Use of the chilling mode BY TIME means that product will be constantly chilleduntil the set chill time, as determined by the operator, has e...
Page 15 - s chill paramaters and begin chilling.; BY PROD
SELECT USER: ↓ ↓ ↓ ↓ ↓ TIM SMITH ↑ ↑ ↑ ↑ ↑ BACK SELECT SELECT PRODUCT: ↑ ↑ ↑ ↑ ↑ CHICKEN PARTS ↓ ↓ ↓ ↓ ↓ SOUP VEGETABLE MAIN MENU SELECT PRODUCT: ↑ ↑ ↑ ↑ ↑ CHICKEN PARTS ↓ ↓ ↓ ↓ ↓ SOUP VEGETABLE MAIN MENU VII. OPERATING THE BLAST CHILL CONTROL - STARTING A CHILL CYCLE -14- MAIN MENU AIR 35 ° F BY TE...
Page 16 - NOTE; F and Holding
VII. OPERATING THE BLAST CHILL CONTROL - STARTING A CHILL CYCLE -15- VII. d - THE CHILL BY PRODUCT FEATURE - PRODUCT LIST:Any product from the PRODUCT LIST can be chilled using the BY PROD mode, once it has been enabled in SetupProducts (page 22). Only CHICKEN PARTS and SOUP VEGETABLE are initially ...
Page 17 - NOTE: Remove food from the blast chiller before proceeding.; HOLDING; MORE
READY TO DEFROSTREQUIRED IN XX MIN. REMOVE FOOD CANCEL START MAIN MENU AIR 35 ° F BY TEMP BY PRODBY TIME 08:05:01 MORE VII. OPERATING THE BLAST CHILL CONTROL - HOLD MODE & DEFROST -16- VII. e - REFRIGERATED HOLD MODE:At the completion of a chill cycle, regardless of the mode used, the Traulsenbl...
Page 18 - VII. OPERATING THE BLAST CHILL CONTROL - PRINTING; However, the following information can always be printed.; CHILL CYCLE REPORT
VII. OPERATING THE BLAST CHILL CONTROL - PRINTING VII. g - PRINTING BATCH/CHILL CYCLE DATA:Once a chill cycle is complete, data can be printed. -17- Press to select DATA.Press to change to a previous date. Press to change to a future date. For multi-batching, press to select probe. Press to select L...
Page 19 - VII. OPERATING THE BLAST CHILL CONTROL - SET UP PRODUCTS; TIM SMITH
VII. h- SET-UP PRODUCTS:Pages 15 and 16 describe the chill BY PRODUCT mode, where the operator canchoose from a preprogrammed list of product chill parameters. As shippedfrom the factory, only two products on the list are enabled and ready fromimmediate use (chicken parts and vegetable soup). To ena...
Page 20 - VII. OPERATING THE BLAST CHILL CONTROL - SET UP USERS
VII. h - SET-UP USERS:The SmartChill ® control offers the convenience of having individual operators h a v e t h e i r o w n u n i q u e B Y P R O D U C T a n d S Y S P A R s e t t i n g s a l r e a d yprogrammed, facilitating the changing chilling needs of different productionshifts. To add new use...
Page 21 - VII. OPERATING THE BLAST CHILL CONTROL - SYSPAR; Press the button to the right of where ENTER appears on; SETUP
S E L E C T S U P E R V I S O R : ↓ ↓ ↓ ↓ ↓ PRESET SUPERVISOR ↑ ↑ ↑ ↑ ↑ ↓ ↓ ↓ ↓ ↓ PASSWORD (PIN): 00 ↑ ↑ ↑ ↑ ↑ CANCEL ENTER MAIN MENU AIR 35 ° F BY TEMP BY PRODBY TIME 08:05:01 MORE SETUP 09:04:11 PRODUCTS SYS PAR USERSMAIN MENU -20- VII. OPERATING THE BLAST CHILL CONTROL - SYSPAR VII. i - ACCESSING...
Page 22 - Last day is corrected for month and leap year.; APRIL
From the SETUP screen, select SYS PAR to get: Press to select SYS PAR. Press to select SYS PAR. Press to decrease ITEM. Press to increase ITEM. Press to decrease VALUE. Press to increase VALUE. Press to return to MAIN MENU* Press to return to SETUP with saving. *without saving. 1) SET CLOCK a) MONTH...
Page 23 - COMMUNICATIONS
VIII. SMARTCHILL TM COMMUNICATIONS -22- VIII. a - INTRODUCTION:All Traulsen SmartChill ® equipped blast chiller models are supplied from the factory capable of on-line communi- cations. However, an optional software/hardware kit is required to make this compatible with your PC. Use ofthis provides m...
Page 25 - X. REPLACEMENT PARTS LIST
X. REPLACEMENT PARTS LIST -24- MODEL NUMBER PART/DESCRIPTION PART # RBC50 CORDSET - 115V 333-13013-01 RBC50 POWER PACK ASSEMBLY 900-60233-00 RBC50/RBC100 6” HIGH STAINLESS STEEL LEGS 344-13168-01 RBC50 STAINLESS STEEL SIDE PANEL 401-60027-01 RBC50 UNIVERSAL TRAY SLIDE 701-60115-00 RBC100 LOUVER ASSE...
Page 26 - XI. SUMMARY OF ERROR MESSAGES
XI. SUMMARY OF ERROR MESSAGES -25- SYSTEM/CONTROL ERRORCURRENT PROBE IS BADCHECK FOOD PROBESPLUGGED IN EXIT XI. a - FOOD PROBE ERROR DURING CHILL CYCLE BY TEMP:In the event of a food probe error during a BY TEMP chill cycle, the controlautomatically switches to a BY TIME chill cycle. The timer will ...
Page 27 - XII. WARRANTY INFORMATION; STANDARD DOMESTIC WARRANTY; INTERNATIONAL COMMERCIAL WARRANTY
-26- XII. WARRANTY INFORMATION STANDARD DOMESTIC WARRANTY TRAULSEN warrants new equipment to the original purchaser, when installed within the UnitedStates against defective material and workmanship for one (1) year from the date of originalinstallation. Under this warranty, TRAULSEN will repair or ...
Page 28 - Quality Refrigeration; XIII. MECHANICAL TROUBLE SHOOTING GUIDE
Traulsen 4401 Blue Mound Road Fort Worth, TX 76106Phone: (800) 825-8220 Fax-Svce: (817) 740-6757Website: www.traulsen.com HOURS OF OPERATION: Monday thru Friday 7:30 am - 4:30 pm CST Quality Refrigeration © 2006 Traulsen - All Rights Reserved a. Check power supply to condensing unit.b. Batch was not...