Page 2 - ÕÉÏÈÅÔÇÓÇ ÍÅÏÕ ØÕÊÔÉÊÏÕ; R22 ðñïêåéìÝíïõ íá âïçèÞóåé óôçí ðñïóôáóßá ôïõ üæïíôïò.
ADOPTION OF NEW REFRIGERANT This Air Conditioner is a new type which adopts a new refrigerant HFC (R410A) instead of the conventional refriger-ant R22 in order to prevent destruction of the ozone layer. UTILISATION DU NOUVEAU REFRIGERANT Ce climatiseur est d’un type inédit qui utilise le nouveau réf...
Page 3 - ÐÅÑÉÅ×ÏÌÅÍÁ; ÅËËÇÍÉÊÁ
CONTENTS SOMMAIRE INHALT INDICE CONTENIDO ÍNDICE ÐÅÑÉÅ×ÏÌÅÍÁ INHOUD ITALIANO ESPA Ñ OL PORTUGU Ê S ÅËËÇÍÉÊÁ FRANCAIS DEUTSCH NEDERLANDS ENGLISH ACCESSORIES (SOLD SEPARATELY) ......................................... 1 PRECAUTIONS FOR SAFETY ....................................................... 1 P...
Page 4 - Remote controller; PRECAUTIONS FOR SAFETY; WARNING; WARNINGS ABOUT INSTALLATION; • Be sure to provide grounding.; CAUTION; TO DISCONNECT THE APPLIANCE FROM THE MAINS SUPPLY; The installation fuse (25A D type; WARNINGS ABOUT OPERATION; a long time as it is bad for the health.; WARNINGS ABOUT MOVEMENT AND REPAIR; • Do not move or repair any unit by yourself.
1 ON / OFF FAN TEMP. SWING/FIX TIME MODE VENT UNIT SET CL FILTERRESET TEST TIMER SET CODE No. UNIT No. TEST SETTING DATA SET R.C. No. H ACCESSORIES (SOLD SEPARATELY) Remote controller PRECAUTIONS FOR SAFETY WARNING WARNINGS ABOUT INSTALLATION • Make sure to ask the qualified installation professiona...
Page 5 - ENGLISH; CAUTIONS ABOUT INSTALLATION
2 ENGLISH CAUTION CAUTIONS ABOUT INSTALLATION • Be sure to confirm the following cautions. • Cer tainly lay the drain hose for perfect draining. Bad drainage may cause flooding in the house and getting furniturewet. • Make sure to connect the air conditioner to an exclusive power supply of the rated...
Page 6 - Button; Outdoor unit; PARTS NAME; Indoor unit
3 Air inlet (Side and rear) Pipes and electric wires Air outlet Remote controller Button Button to open/close the suction port Air filter Removes dust or trash.(Provided on the suction port.) Discharge flap of discharge port Change the direction of the air to be discharged according to cool/heat mod...
Page 7 - PARTS NAME OF REMOTE CONTROLLER; Display section; In reality only, the selected contents are indicated.; • When turning on the leak breaker at the first time, [SET; If “FILTER; TEST run display; Displayed during a test run.; Flap position display; Displays flap position.; SWING display
4 PARTS NAME OF REMOTE CONTROLLER Display section In the display example, all indicators are displayed for the explana-tion. In reality only, the selected contents are indicated. • When turning on the leak breaker at the first time, [SET DATA] flashes on the display part of the remote controller.Whi...
Page 8 - Operation section
5 Operation section Push each button to select a desired operation. • The details of the operation needs to be set up once, afterward, the air conditioner can be used by pushing ON / OFF button only. 1 Air volume select button Selects the desired air volume mode. 2 Timer set button TIMER SET button ...
Page 9 - Select air volume with “; Determine the set up temperature by pushing the “TEMP.; Stop; Push; CORRECT USAGE; Preparation; Turn on the main power switch and/or the leakage breaker.; REQUIREMENT
6 1 Push ON / OFF button. The operation lamp goes on, and the operation starts. 2 Select an operation mode with the“MODE MODE ” button. One push of the button, and the displaychanges in the order shown on the right. • In HEAT mode, if the room temperature reaches to the set temperature, the outdoor ...
Page 10 - Start; button; NOTE; When restarting the operation after stop
7 AUTOMATIC OPERATION (Auto Changeover) When you set the air conditioner in mode or switch over from AUTO operation because of some settings change, it will automatically select either cooling, heating, or fan only operation depending on the indoortemperature. 1 2 3 ON / OFF FAN TEMP. SWING/FIX TIME...
Page 11 - ADJUSTMENT OF WIND DIRECTION; How to set up the wind direction; In HEAT operation; How to start swinging; How to stop swinging
8 In FAN operation In all modes Display when stopping the swing Initial setup Series of operation Fan/Heat operation Cool/Dry operation ON / OFF FAN TEMP. SWING/FIX TIME MODE VENT UNIT SET CL FILTERRESET TEST TIMER SET ADJUSTMENT OF WIND DIRECTION • When the air conditioner stops, the flap (adjustme...
Page 12 - TIMER OPERATION; Timer operation; Push TIMER SET button.; to select “SET TIME”.; Cancel of timer operation
9 TIMER OPERATION A type of timer operation can be selected from the following three types. OFF timer : The operation stops when the time of timer has reached the set time. Repeat OFF timer : Every time, the operation stops after the set time has passed. ON timer : The operation starts when the time...
Page 13 - HINTS FOR ECONOMICAL OPERATION; Never open doors and windows more often than necessary; In cooling, close the cur tains to avoid direct sunlight.; Get uniform circulation of room air
10 HINTS FOR ECONOMICAL OPERATION Maintain room temperature at comfortable levelClean air filters The clogged air filter impairs the performance of the air conditioner. Never open doors and windows more often than necessary To keep cool or warm air in the room, never open doors and windows more ofte...
Page 14 - If you do not plan to use the unit for more than 1 month; • Operate “FAN ONLY” mode with set temperature 30°C.; Checks before operation; MAINTENANCE; Cleaning of remote controller
11 If you do not plan to use the unit for more than 1 month (1) Operate the fan for 3 to 4 hours to dry inside the unit • Operate “FAN ONLY” mode with set temperature 30°C. (2) Stop the air conditioner and turn off the main power switch or the circuit breaker. Checks before operation (1) Check that ...
Page 15 - AIR CONDITIONER OPERATIONS AND PERFORMANCE; Power failure during operation will stop the unit completely.
12 AIR CONDITIONER OPERATIONS AND PERFORMANCE 3 minutes protection function 3-minutes protection function prevents the air conditioner from starting for initial 3 minutes after the mainpower switch/circuit breaker is turned on for re-starting the air conditioner. Power failure Power failure during o...
Page 16 - DANGER; Do not install the air conditioner in the following places; TROUBLES AND CAUSES
13 RE-INSTALLATION DANGER Ask the dealer or an installation professional to re-install the air conditioner to a new place ormove it to another place and to observe the following items. If the air conditioner is inappropriate installed by yourself, it may cause electric shock or fire. Do not install ...
Page 17 - These are not failures.
14 Before you ask for servicing or repairs, check the following points. Inoperative • The main power switch is turned off. • The circuit breaker is activated to cut off power supply. • The main power fuse has blown out. • Stoppage of electric current. Does not cool well or heat well • The air inlet ...
Page 18 - TOSHIBA CARRIER CORPORATION
EH99923701 TOSHIBA CARRIER CORPORATION 2 CHOME 12-32, KONAN, MINATOKU, TOKYO, 108-0075, JAPAN This product is compliant with Directive 2002/95/EC, and cannot be disposed as unsorted municipal waste. Ce produit est conforme à la Directive 2002/95/CE et il ne peut pas être jeté avec les ordures ménagè...