Page 2 - Introduction; PROGRAM 0 –; PROGRAM 0; location S1; diff
2 Introduction Note: The information supplied in this manual is for guidance only - no part of this may be used for any agreement, whether express or implied, or to form any contract. Thermo Technologies reserves the right to change specifications without prior notice. SDT 2004 is a powerful tempera...
Page 3 - INSTALLATION; When installing the unit, all required; ensor; Either push into a thermowell,
3 INSTALLATION Note: This installation procedure is for guidance only, and the installer should verify its suitability. Make sure that the solar system is physically installed, manually tested, and ready for controlled operation. he following sa fety precautions are strongly recommended: 1. Before a...
Page 4 - The sensor required for the solar loop return is installed; Pool sensor installation:; Place a heat conductive T-piece on the suction line directly at the; Sensor cable extension:
4 strap the sensor to the collector outlet pipe or the absorber (flat plate collectors) that projects from the collector housing. Ideally, house the collector sensor (encased in a suitable sensor pocket) into a T-piece on the collector return outlet. Protect the sensor cable from UV and moistur e. l...
Page 5 - Base of the unit to be mounted at eye -level and wired as shown above
5 Undo the screw at the top of the housing. The control electronics are mounted on the enclosure cover. The controller enclosure can be screwed to the wall with cable entry grommets pointed downwards. Use the supplied plastic bridges to secure power and sensor cables. Base of the unit to be mounted ...
Page 6 - our
6 ower Connections: A small blade screwdriver may be used to fasten miniaturized terminal block screws while the corresponding wire is inserted. NOTE 1: Always disconnect the controller from power supply before opening the housing. NOTE 2: The controller should be properly grounded. Flexible wires, ...
Page 7 - ïð; Operation Mode –
7 Use selection keys ïð during normal system operation to display the desired parameter: T1 xxx Collector temperature in o F T2 xxx Tank temperature in o F T3 xxx Reading of the third sensor; if the third sensor is not used it displays a fixed reference temperature of 250 o F XX xxx Collector power ...
Page 10 - Men; Men Domain
10 m a x = 2 Pump runs again below this set point (T3) Energy calculation mode (PROGRAM 1) : USDT 2004 computes the energy production as a function of the temperature differential and fluid volume. In addition, the system anti-freeze (Glycol) percentage should be entered as it affects the thermal co...
Page 14 - roubleshooting; Check program number.
14 T roubleshooting In general, all of the settings in the menus Par and Men and the terminal should first be checked if there is a malfunction. Malfunction, but "realistic" temperature values: • Check program number. • Check the switch- on and switch-off thresholds and the set differential ...