Page 2 - Table of Contents; IP; BILL
2 Table of Contents 1 INTRODUCTION.............................................................................................................................................. 3 2 CONNECTING NEO TO THE WORLD ..............................................................................................
Page 3 - Introduction
3 1 Introduction The NEO-10 device is a network based Input Output device. Within its enclosure are 10 DPDT relays with all 6 contacts of the relays brought out to ports (Normally Open, Normally Close, Common for each half of relay). There are also 10 diode blocked inputs which can be used to monito...
Page 4 - Connecting NEO to the World; Connector View
4 2 Connecting NEO to the World NEO has a total of three different ports that are used to connect it to the world. Likely, the first port that will need to be connected is the RS-232 port. 2.1 RS-232 Port The RS-232 port is used for initial setup purposes only. It is a standard DCE pinout allowing a...
Page 5 - Software Configuration of NEO; Setting the basic IP information with Hyperterminal; Once these values have been; Load Hyper Terminal in your PC setting the name to COM.
5 3 Software Configuration of NEO Setup of the NEO is almost entirely done using a web browser. The first step required during setup is to assign the IP and Mask addresses to the NEO, using either a WEB Browser or Hyper Terminal program if the assigned IP address is not accessible on your network. 3...
Page 8 - General Setup via Web Pages; page shown in Figure 3.; Basic Ethernet Setup Screen; DHCP
8 3.2 General Setup via Web Pages The majority of the setup of the NEO is completed through the Ethernet port. Once the steps of 3.1 have been completed, a PC on the network can be used to gain access to the web page based setup of the NEO. In the URL window of Internet Explorer, type http://X.X.X.X...
Page 10 - Multicast Setup
10 3.4 Multicast Setup A single multicast address is employed by NEO for the purpose of updating consoles of changes in the Relays and Inputs. NEO sends out a single packet each time either a Relay is changed by any console or when an input changes due to external event. The Multicast Address is any...
Page 11 - Debounce Input Settings; The Debounce hyperlink will open the screen below.
11 3.5 Debounce Input Settings The Debounce hyperlink will open the screen below. Each of the 10 inputs can have its own input debounce time. This is the amount of time, in milliseconds, that the input is allowed to stabilize from first change detection to final sampling. The timer resolution is onl...
Page 14 - Clone From Other NEO
14 3.7 Clone From Other NEO The Clone function allows for the parameters of one NEO to be copied to another over the network. Simply enter the IP address of the unit to copy the parameters from and press the submit button . The parameters will be copied. The only parameters that are not copied are t...
Page 16 - Save Changes to EEPROM
16 3.9 Save Changes to EEPROM As each group of settings are changed and submitted, they still must be saved to EEPROM to be stored permanently. Some settings require reboot of the device to take effect. These are primarily IP parameters. Figure 10 - Save to EEPROM
Page 17 - BILL OF MATERIAL AND SCHEMATICS
Page 18 - Telex Communications INC.
REVISIONS REV DESCRIPTION ECO NO DATE APPD 1 PROTOTYPE 09/16/03 This drawing, written description or specification Is a proprietary product of TELEX, Lincoln, NE, and shall not be released, disclosed, nor duplicated without the written permission of TELEX. Telex Communications INC. Lincoln, Nebraska...
Page 19 - QT
ITEM NE W QT Y TYPE DESCRIPTION PART NO. DESIGNATOR 1 14 CAP 10uf 16vTANT 3528 B 102877065T C1 C3 C11 C18 C19 C68 C71 C73 C74 C123 C124 C131 C162 C329 2 15 CAP 0805 0.1UF 25V +/-10% 102881186T C6 C7 C8 C9 C10 C12 C13 C29 C30 C56 C69 C72 C75 C330 C59 3 1 CAP 1000U,ELECTROLYTIC,LEADED DO NOT PLACE C15...
Page 26 - ith your equipment.; TELEX Communications, Inc; Vega Signaling Products; Visit our web site at
18 5 Warranty, Service, Repair, and Comments Important! Be sure the exact return address and a description of the problem or work to be done are enclosed w ith your equipment. Warranty (Limited) All Telex Manufactured Vega signaling products are guaranteed against malfunction due to defects in mater...