Page 2 - Amps; Product Offering
Advance Data Sheet: Dualeta™ iQA Series – Dual Quarter Brick ©2001-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 ℡ (877) 498-0099 2/19 Ordering information Product Identifier Package Size Platform Input Voltage Output Current/ Power Output Units Main Output Voltage # of Outputs Safety...
Page 3 - PIN
Advance Data Sheet: Dualeta™ iQA Series – Dual Quarter Brick ©2001-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 ℡ (877) 498-0099 3/19 Mechanical Specification Dimensions are in mm [in]. Unless otherwise specified tolerances are: x.x ± 0.5 [0.02], x.xx and x.xxx ± 0.25 [0.010]. Recomm...
Page 4 - Input Characteristics:
Advance Data Sheet: Dualeta™ iQA Series – Dual Quarter Brick ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 ℡ (877) 498-0099 4/19 Absolute Maximum Ratings: Stress in excess of Absolute Maximum Ratings may cause permanent damage to the device. * Engineering estimate. Input Charact...
Page 5 - Advance Data Sheet: DualetaTM iQA Series – Dual Quarter Brick; Characteristic
Advance Data Sheet: Dualeta™ iQA Series – Dual Quarter Brick ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 ℡ (877) 498-0099 5/19 Electrical Data: iQA48015A033M: 3.3V/2.5V, 15A Output Characteristic Min Typ Max Unit Notes & Conditions Output Voltage Initial Setpoint Vout1 Vou...
Page 6 - Typical Efficiency vs. Input Voltage at Ta=25
Advance Data Sheet: Dualeta™ iQA Series – Dual Quarter Brick ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 ℡ (877) 498-0099 6/19 Electrical Characteristics: iQA48015A033M: 3.3V/2.5V, 15A Output 70 72 74 76 78 80 82 84 86 88 0 20 40 60 80 100 Output Cur r e nt (% full load) Io1=I...
Page 7 - Typical Input Current vs. Input Voltage Characteristics.
Advance Data Sheet: Dualeta™ iQA Series – Dual Quarter Brick ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 ℡ (877) 498-0099 7/19 Electrical Characteristics (continued): iQA48015A033M: 3.3V/2.5V, 15A Output Typical Vo1 load transient response. Io1 step from 3.75A to 7.5A with 0.1...
Page 8 - Trim up – tracking trim option; Rdown is connected between Trim and Vout2.
Advance Data Sheet: Dualeta™ iQA Series – Dual Quarter Brick ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 ℡ (877) 498-0099 8/19 Electrical Characteristics (continued): iQA48015A033M: 3.3V/2.5V, 15A Output 0 0.5 1 1.5 2 2.5 3 3.5 25 30 35 40 45 50 55 60 65 70 75 Input V oltage (...
Page 12 - Trim up – independent trim; Rup1 is connected between Trim1 and Vout1.; Rup; Trim down – independent trim; Rdown1 is connected between Trim1 and RTN.
Advance Data Sheet: Dualeta™ iQA Series – Dual Quarter Brick ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 ℡ (877) 498-0099 12/19 Electrical Characteristics (continued): iQA48015A050M: 5V/3.3V, 15A Output 0 1 2 3 4 5 6 25 30 35 40 45 50 55 60 65 70 75 Input V oltage (V ) O ut pu...
Page 14 - Test Setup; AIRFLOW; ) and airflow rate as shown in the
Advance Data Sheet: Dualeta™ iQA Series – Dual Quarter Brick ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 ℡ (877) 498-0099 14/19 Thermal Management: An important part of the overall system design process is thermal management; thermal design must be considered at all levels to ...
Page 15 - For applications with; Operating Information
Advance Data Sheet: Dualeta™ iQA Series – Dual Quarter Brick ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 ℡ (877) 498-0099 15/19 thermal performance figures in the Thermal Performance section. The curves in the figures are shown for natural convection through 3 m/s (600 ft/min)...
Page 16 - Output Voltage Adjustment; Circuit to decrease output voltage; Circuit to increase output voltage
Advance Data Sheet: Dualeta™ iQA Series – Dual Quarter Brick ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 ℡ (877) 498-0099 16/19 Remote On/Off The power modules have an internal remote On/Off circuit. The user must supply an open-collector or compatible switch between the Vin (...
Page 17 - Optional Tracking Trim; Innoveta power
Advance Data Sheet: Dualeta™ iQA Series – Dual Quarter Brick ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 ℡ (877) 498-0099 17/19 With a resistor between the trim and Vo (+) terminals, the output voltage is adjusted up. To adjust the output voltage up a percentage of Vout (%Vo) ...
Page 18 - Reliability
Advance Data Sheet: Dualeta™ iQA Series – Dual Quarter Brick ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 ℡ (877) 498-0099 18/19 Input/Output Ripple and Noise Measurements 100KHz Voutput Cext 1 2 + 12uH 1 2 esr<0.7 Battery 100KHz + RLoad 1 2 esr<0.1 - Vinput 220uF 1 2 Gro...
Page 19 - hazardous voltages do not appear at the module output.; is a trademark or registered trademark of TDK Corporation.
Advance Data Sheet: Dualeta™ iQA Series – Dual Quarter Brick ©2004 TDK Innoveta® Inc. iQAFullDatasheet080505_2.doc 8/3/2006 Revision 2.0 ℡ (877) 498-0099 19/19 Safety Considerations For safety agency approval of the system in which the DC-DC power module is installed, the power module must be instal...