Page 2 - Complete this page for quick reference when service is required:; Date of Installation:; Information found on the data label:; Voltage; Taylor Company
Complete this page for quick reference when service is required: Taylor Distributor: Address: Phone: Service: Parts: Date of Installation: Information found on the data label: Model Number: Serial Number: Electrical Specs: Voltage Cycle Phase Maximum Fuse Size: A Minimum Wire Ampacity: A E 2010 Carr...
Page 3 - Table of Contents
Table of Contents Models 358 & 359 Table of Contents Section 1 To the Installer 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installer Safety 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 4 - Table of Contents - Page 2
Models 358 & 359 Table of Contents Table of Contents - Page 2 Disassembly 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Brush Cleaning 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 5 - To the Installer; Section 1; Installer Safety; NOT
1 Models 358 & 359 To the Installer 131125 Section 1 To the Installer The following information has been included in themanual as safety and regulatory guidelines. Forcomplete installation instructions, please see theInstallation Checklist. Installer Safety In all areas of the world, equipment s...
Page 6 - Air Cooled Units; DO NOT; Electrical Connections; CAUTION: THIS EQUIPMENT MUST BE; Beater Rotation
2 Models 358 & 359 To the Installer 131125 Air Cooled Units DO NOT obstruct air intake and discharge openings: Air cooled units require a minimum of 3” (76 mm) ofclearance around all sides of the freezers and 3-1/2”(89 mm) on the bottom.Model 359 only: Installation of air deflector isrequired.Fa...
Page 7 - Refrigerant
3 Models 358 & 359 To the Installer 131125 Refrigerant In consideration of our environment, Taylor uses only earth friendly HFC refrigerants. The HFCrefrigerant used in this unit is R404A. Thisrefrigerant is generally considered non-toxic andnon-flammable, with an Ozone Depleting Potential(ODP) ...
Page 8 - To the Operator; Section 2; Compressor Warranty Disclaimer; only the refrigerant
4 Models 358 & 359 To the Operator 131125 Section 2 To the Operator Your freezers have been carefully engineered andmanufactured to give you dependable operation.These units, when properly operated and cared for,will produce a consistent quality product. Like allmechanical products, they will re...
Page 9 - Safety; Section 3; IMPORTANT - Failure to adhere to the
5 Models 358 & 359 Safety 131125 Section 3 Safety We, at Taylor Company, are concerned about thesafety of the operator when he or she comes incontact with the freezer and its parts. Taylor hasgone to extreme efforts to design and manufacturebuilt-in safety features to protect both you and theser...
Page 11 - Operator Parts Identification; Section 4
7 Models 358 & 359 Operator Parts Identification Section 4 Operator Parts Identification Model 358 Figure 1 ITEM DESCRIPTION PART NO. 1 COVER A.-HOPPER INSUL X51658 2 TUBE-FEED-NONREVERS 015176-5 3 PANEL-REAR 046021 4 PANEL-SIDE *358* RIGHT 046023-SP1 5 FILTER A.-13 X 16-7/8 X 7/16 046044 6 STUD...
Page 13 - Beater and Door Assembly
9 Models 358 & 359 Operator Parts Identification Beater and Door Assembly Figure 3 ITEM DESCRIPTION PART NO. 1 SEAL-DRIVE SHAFT 032560 2 SHAFT-BEATER 033235 3 BEATER A.-7 QT. - 1 PIN X46233 4 BEARING-FRONT 013116 5 GASKET-DOOR - 5.177 ID X5.9380 016672 ITEM DESCRIPTION PART NO. 6 VALVE A.-DRAW X...
Page 14 - Accessories
10 Models 358 & 359 Operator Parts Identification Accessories Figure 4 ITEM DESCRIPTION PART NO. 1 KIT ASSEMBLY-TUNE UP *358 X46050 KIT ASSEMBLY-TUNE UP *359 X36356 2 BRUSH-REAR BEARING 013071 3 BRUSH-DOUBLE ENDED 013072 ITEM DESCRIPTION PART NO. 4 BRUSH-DRAW VALVE 014753 5 BRUSH-HOPPER 3” x 7” ...
Page 15 - Important: To the Operator; Section 5
11 Models 358 & 359 Important: To the Operator Section 5 Important: To the Operator Model 358 Model 359 Figure 5 Figure 6 ITEM DESCRIPTION 1 POWER SWITCH 2 MIX OUT INDICATOR 3 RESET BUTTON ITEM DESCRIPTION 1 MIX OUT INDICATOR-LEFT SIDE 2 POWER SWITCH-LEFT SIDE 3 MIX OUT INDICATOR-RIGHT SIDE 4 PO...
Page 16 - Power Switch; Indicator Light - “Mix Out”; Reset Button; Note: Do not use metal objects to press; Air Tube
12 Models 358 & 359 Important: To the Operator Power Switch The middle position is “OFF”. The left position is“WASH”, which activates the beater motor only. Theright position is “AUTO”, which activates the beatermotor and the refrigeration system. Figure 7 Indicator Light - “Mix Out” The “MIX OU...
Page 17 - Operating Procedures; Section 6; gravity; Assembly; MAKE SURE THE POWER SWITCH IS IN
13 Models 358 & 359 Operating Procedures Section 6 Operating Procedures The Model 358 has been selected to show you thepictured step-by-step operating procedures for bothmodels contained in this manual. These models, forpractical purposes of operation, are the same. These models store 20 quarts ...
Page 20 - Sanitizing; Be sure your hands are sanitized
16 Models 358 & 359 Operating Procedures Sanitizing Step 1 Prepare an approved 100 PPM sanitizing solution(examples: 2-1/2 gal. [9.5 liters] of Kay-5 R or 2 gal. [7.6 liters] of Stera-Sheen R ). USE WARM WA- TER AND FOLLOW THE MANUFACTURER'SSPECIFICATIONS. Step 2 Pour the sanitizing solution int...
Page 21 - Priming; two
17 Models 358 & 359 Operating Procedures Step 6 Stand the air tube in the corner of the mix hopper. Figure 25 Repeat Steps 1 through 6 for the other side of the freezer on the Model 359. Priming Step 1 With a pail beneath the door spout, raise the drawhandle. Pour two gallons (7.6 liters) of fre...
Page 22 - Closing Procedure; Rinsing
18 Models 358 & 359 Operating Procedures 140804 Step 5 Place the mix hopper cover in position over the mixhopper. Figure 29 Repeat Steps 1 through 5 for the other side of the freezer on the Model 359. Closing Procedure To disassemble your unit, the following items will beneeded: S Two cleaning p...
Page 23 - Cleaning; Repeat Steps 1 through 5; Disassembly; Brush Cleaning
19 Models 358 & 359 Operating Procedures Cleaning Step 1 Prepare an approved 100 PPM cleaning solution(examples: 2-1/2 gal. [9.5 liters] of Kay-5 R or 2 gal. [7.6 liters] of Stera-Sheen R ). USE WARM WATER AND FOLLOW THE MANUFACTURER'SSPECIFICATIONS. Step 2 Pour the cleaning solution into the mi...
Page 25 - Important: Operator Checklist; Section 7; During Cleaning and Sanitizing; CLEANING AND SANITIZING MUST BE; Troubleshooting Bacterial Count
21 Models 358 & 359 Important: Operator Checklist Section 7 Important: Operator Checklist During Cleaning and Sanitizing ALWAYS FOLLOW LOCAL HEALTH CODES. Cleaning and sanitizing schedules are governedby federal, state, or local regulatory agencies,and must be followed accordingly. If the unitha...
Page 26 - monthly; CAUTION: Always disconnect; Winter Storage; This is extremely
22 Models 358 & 359 Important: Operator Checklist j 4. Dispose of o-rings and seals if they are worn, torn, or fit too loosely, and replace with newones. j 5. Follow all lubricating procedures as outlined in “Assembly”. j 6. If your machine is air cooled, check the condenser for accumulation of ...
Page 27 - Troubleshooting Guide; Section 8; PROBLEM
23 Models 358 & 359 Troubleshooting Guide Section 8 Troubleshooting Guide PROBLEM PROBABLE CAUSE REMEDY PAGE REF. 1. No product is being dispensed with draw valveopen and machine in the“AUTO” mode. a. Beater motor is out on reset. a. Reset the freezer. 12 b. Circuit breaker off or blown fuse. b....
Page 30 - Parts Replacement Schedule; Section 9
26 Models 358 & 359 Parts Replacement Schedule Section 9 Parts Replacement Schedule PART DESCRIPTION EVERY 3 MONTHS EVERY 4 MONTHS EVERY 6 MONTHS ANNUALLY 358 QTY. 359 QTY. Drive Shaft Seal X 1 2 Scraper Blade X 2 4 Freezer Door Gasket X 1 2 Front Bearing X 1 2 Draw Valve O-Ring X 2 4 Black Bris...
Page 31 - Section 10 Limited Warranty on Equipment
27 Models 358 & 359 Limited Warranty on Equipment 131125 Section 10 Limited Warranty on Equipment TAYLOR COMPANY LIMITED WARRANTY ON FREEZERS Taylor Company, a division of Carrier Commercial Refrigeration, Inc. (“Taylor”) is pleased to provide this limitedwarranty on new Taylor-branded freezer e...
Page 32 - Limited Warranty on Equipment; LIMITATION OF WARRANTY; must
28 Models 358 & 359 Limited Warranty on Equipment 3. Replacement of wear items designated as Class “000” parts in the Taylor Operator’s Manual. 4. External hoses, electrical power supplies, and machine grounding. 5. Parts not supplied or designated by Taylor, or damages resulting from their use....
Page 33 - Limited Warranty on Parts
29 Models 358 & 359 Limited Warranty on Parts 131125 Section 11 Limited Warranty on Parts TAYLOR COMPANY LIMITED WARRANTY ON TAYLOR GENUINE PARTS Taylor Company, a division of Carrier Commercial Refrigeration, Inc. (“Taylor”) is pleased to provide this limitedwarranty on new Taylor genuine repla...
Page 34 - not
30 Models 358 & 359 Limited Warranty on Parts LIMITED WARRANTY EXCEPTIONS This limited warranty does not cover: 1. Labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling ofdefective Parts, replacement Parts, or new Parts. 2. Normal maintena...