Page 2 - SOFTWARE INSTALLATION; CONTENTS
C M Y CM MY CY CMY K 2 1.0: IMPORTANT SAFETY INSTRUCTIONS 2.0: INTRODUCTION 3.0: THE BASICS 3.1 Unpacking and visual checks 3.2 Preliminary recommendation 4.0: INTERF ACE P ANEL 5.0: OPERATION 5.1: AC power requirements 5.2 Cooling 5.3 LED functions 5.4 Limiters 5.5 Audio Connections 5.6 User DSP on...
Page 4 - INSTALLATION INSTRUCTIONS; Product safety; FOR CUSTOMERS IN THE USA & CANADA; VNET“
C M Y CM MY CY CMY K 4 INSTALLATION INSTRUCTIONS 1 THIS PRODUCT MUST BE EARTHED. Use only a flexible cable or cord provided with a green or green and yellow corewhich must be connected to the protective earthing terminal of the detachable Neutrik ’Powercon’ type NEC3FCA connector (Tannoy part number...
Page 5 - VNet
C M Y CM MY CY CMY K 5 2.0: INTRODUCTION The Tannoy VNET12HP & VNET15 loudspeakers utilise high performance Dual Concentric“ drive units — the 12 (300mm) PowerDual“ and the 15 (380mm) PowerDual“. The substantially increased efficiency and power handling of these all-newdriver designs ensures tha...
Page 6 - Amplifier & DSP Panel; Every Tannoy
C M Y CM MY CY CMY K CM I N T E R T E K L I S T E D C US THIS CLASS D DIGITAL DEVICE MEETS ALL REQUIREMENTS OF THECANADIAN INTERFERENCE-CAUSING EQUIPMENT REGULATIONS ANDCOMPLIES WITH PART 15 OF THE FCC RULES.OPERATION SUBJECT TO CONDITIONS STATED IN THE MANUAL. WARNING TO REDUCE THE RISK OF FIRE OR ...
Page 7 - AC Power Requirements; NAC3FCA; Cable; Audio Connections; The signal input & link connectors are fully balanced.; SIGNAL; When connecting a balanced signal be sure to wire
C M Y CM MY CY CMY K 7 TM 5.1: AC POWER REQUIREMENTS AC Power Requirements VNET“ products are equipped with Neutrik Powercon“ mains connectors which mate with the Neutrik NAC3FCA Cable connector, quick lock with a securing lever for power-in. This AC mains connector is supplied with each VNET“ produ...
Page 8 - Always run a signal ground with RS-485; example network; position will return the; switch to the; OFF; VNET Series
C M Y CM MY CY CMY K 6.0: NETWORK CONNECTIONS Interconnection between the network computer and the speakers is very straight forward, using twisted pair cable and simpleconnectors. The RS485 interface operates on a shared bus so that a single computer can control any amplifier on the bus,and the com...
Page 9 - Device RJ45 To Vnet Network
C M Y CM MY CY CMY K 9 4.5: USER DSP ON/OFF Connections from the RS485 device to the speaker is as follows:- From RS485 Device RJ45 To Vnet Network B+ Pin 1 A - Pin 2 GND Pin 5 Network connections between nodes are via rugged Neutrik ethercon connectors; these are high quality and are compatiblewith...
Page 11 - The programme will begin installing
C M Y CM MY CY CMY K 11 7.0 SOFTWARE INSTALLATION TM 3. Confirm Installation. Click <Next> 4. If you accept the licence agreement check I Agree andClick <Next> 5. The programme will begin installing 6. Installation Complete
Page 12 - SOFTWARE OPERATION; Menus; The menu system is arranged like so:; File; The toolbar provides the following one-click functions:
C M Y CM MY CY CMY K 8.0 SOFTWARE OPERATION 12 Menus The menu system is arranged like so: File Open opens a file which contains parameters for the device Save saves the current settings in the current file name Save As saves the current settings under a new file name Exit closes the application Devi...
Page 14 - parameter synchronisation; Single parameters may be adjusted ’live’ whilst On-line .; Drop-Down Selector boxes
C M Y CM MY CY CMY K 8.0 SOFTWARE OPERATION 14 The control panel shows the model name (not editable), and firmware version for the device. The device properties panel also have an editableConfiguration Name, and Loudspeaker name, the latter will appear in thetree menu after editing. Each panel will ...
Page 16 - Audio Processing; provides the following processing options:; Equalisation Filters
C M Y CM MY CY CMY K 7.0 SOFTWARE OPERATION Audio Processing VNET“ provides the following processing options: • • Crossover filtering with frequency variable over the range 10Hz to 25kHz (and Out ) with the following alignments: • 1 st order • 12dB/Octave Bessel • 12dB/Octave Butterworth • 12dB/Octa...
Page 20 - I N
C M Y CM MY CY CMY K 20 11.0 DIMENSIONS VNET 12 & 12HP 180.0 290.0 370.0 175.0 360.0 30 ∞ 50 ∞ 486.0 40.0 406.0 153.0 180.0 175.0 CM I N T E R T E K L I S T E D C US 115-230V 50-60Hz 1000VA THIS CLASS D DIGITAL DEVICE MEETS ALL REQUIREMENTS OF THECANADIAN INTERFERENCE-CAUSING EQUIPMENT REGULATIO...
Page 22 - PERFORMANCE DATA; VNET12 Anechoic Frequency Response
C M Y CM MY CY CMY K 2 2 12.0 PERFORMANCE DATA VNET12 Anechoic Frequency Response VNET12 HP Anechoic Frequency Response VNET300 Anechoic Frequency Response VNET15 Anechoic Frequency Response
Page 23 - SYSTEM V; Average; CONSTRUCTION
C M Y CM MY CY CMY K TM 13.0: TECHNICAL SPECIFICATIONS SYSTEM V NET 12 V NET 12HP V NET 15 V NET 300 System Type Full Range - Vented Full Range - Vented Full Range - Vented Full Range — Vented Frequency Response (1) +/- 2dB 60Hz - 25kHz 55Hz - 23Hz 40Hz - 23Hz 45Hz - 23kHz Maximum SPL(2) Average 120...
Page 24 - System Type; ELECTRONICS
C M Y CM MY CY CMY K 24 SYSTEM V NET 15BP V NET 15HL V NET 18DR System Type Subwoofer - Band Pass Full Range — Horn Loaded Full Range — Direct Radiating Frequency Response (1) +/- 3dB 35Hz - 150Hz 48Hz - 250Hz 27Hz - 200Hz Maximum SPL (2) Average 127dB 130dB 130dB Peak 133dB 136dB 136dB Driver Compl...
Page 26 - Description
C M Y CM MY CY CMY K 26 Use the table of parts along with the assembly drawing (Figure 3.) to assemble the VMY.Figure 4 shows the VMY assembled. Fig.1 Fig.2 Number on Assembly View (Fig 3.) Description Quantity 1 Hanging Bracket 2 2 Cross Member 1 3 Pivot Stud 2 4 M10 Plain Washer 2 5 M8 Spring Wash...
Page 29 - The Tannoy; only; be used for tilting the loudspeaker
C M Y CM MY CY CMY K 29 TM 14.4 : SECUR ET - VEB EYEBOLT The Tannoy VNET“ loudspeaker can be flown with high quality VEB M10 eyebolts with collar to BS4278:1984. The loudspeakersare equipped with internal steel braces, which also double as theflying points, and accept VEB M10 eyebolts. To install th...
Page 30 - VPC Pole Clamp
C M Y CM MY CY CMY K 30 14.5 : SECUR ET - VTH POLE MOUNT The Tannoy VNET“ loudspeakers are fitted as standard with a blanking plate on the base of the cabinet. However, should you everwish to mount the VNET“ onto a standard 35mm pole mount this blanking plate can be quickly and easily removed and re...
Page 31 - Full Range; VNET HARDWARE
C M Y CM MY CY CMY K 31 TM 15.0: SERVICE PARTS & ACCESSORIES Full Range VNET Amplifier & DSP Module 7300 1045 Duals 7300 1062 Subs VNET12 7900 0433 Driver Kit - 3142 7900 0441 Recone Kit - 3142 7900 0199 HF Diaphragm Kit VNET12HP 7900 0715 Driver Kit - 3190 7900 0716 Recone Kit — 3190 7900 0...
Page 32 - No maintenance of the; loudspeakers is necessary.; Details of the Apparatus:
C M Y CM MY CY CMY K 16.0: WARRANTY No maintenance of the VNET“ loudspeakers is necessary. All Tannoy professional loudspeaker products are covered by a 5 year warranty from the date of manufacture (1 year for electronics), subjectto the absence of misuse, overload or accidental damage. Claims will ...