TANDBERG Maestro MXP ii Trademarks and Copyright All rights reserved. This document contains information that is proprietary to TANDBERG. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, electronically, mechanically, by photoc...
User Manual v Environmental Issues Thank you for buying a product which contributes to a reduction in pollution, and thereby helps save the environment. Our products reduce the need for travel and transport and thereby reduce pollution. Our products have either none or few consumable parts (chemical...
User Manual vii Operator Safety Summary Operator Safety Summary For your protection please read these safety instructions completely before you connect the equipment to the power source. Carefully observe all warnings, precautions and instructions both on the apparatus and in these operating instruc...
TANDBERG Maestro MXP x Table of Contents 1 Introduction ............................................................................................................................. 14 1.1 At a Glance ......................................................................................................
1 Introduction The TANDBERG Maestro MXP provides high-end performance features, high resolution quality video and precision audio. This creates a collaborative meeting environment for medium to large-sized meeting rooms. TANDBERG Precision HD Camera To provide customers with optimal video processing...
TANDBERG Maestro MXP 24 2 Installation Precautions: Never install communication wiring during a lightning storm. Never install jacks for communication cables in wet locations unless the jack is specifically designed for wet locations. Never touch uninstalled communication wires or terminals un...
Installation 25 2.1 Unpacking and Mounting 1 Unpacking The TANDBERG Maestro is delivered in one transport case with all components inside. Remove the case in the order shown on Figure 1. Figure 1 The accessories box contains: TANDBERG Precision HD Camera 2x Table Microphones Remote Control and...
Installation 27 2.2 Connecting Cables 1. Power cable Find the right power cable that works for your country in the accessories box, and connect to power cable from base, and to an electrical distribution socket. 2. Microphone cable Connect the microphone cable to the microphone. 3. a) ISDN BRI Conne...
Installation 29 2.3 Monitor Configuration Configuration of external display (projector) Select 16:9 or 4:3 format on the projector. Make sure that the main projector is connected to the DVI-I Single output on the codec. Please refer to the projector user manual for further information.
TANDBERG Maestro MXP 30 2.4 System Configuration The system must be configured for each installation. Configuration settings can be made via the system menu. If an external IMUX or non-standard network is being used it may be necessary to configure any associated external equipment. Navigate through...
3 General Use Wake up the system When the system is not in use, it is in standby mode and the screens are black. Wake up the system by picking up the remote control. An incoming call or pressing any key on the remote control will also wake up the system. If the system does not respond: Make sure t...
TANDBERG Maestro MXP 34 3.1 The Welcome Screen When the system is switched on, the welcome screen will be displayed. The welcome screen presents the menu and displays your main camera image in the background (display main camera is the default setting). The ISDN/IP numbers and the system name are di...
Administrator Settings 35 3.2 Using the Remote Control The system is controlled with a remote control. Think of the remote control as a mobile phone with number keys and call keys. Use the arrow keys and press OK to navigate through the menus. The system’s most commonly used functions are also acces...
TANDBERG Maestro MXP 40 3.2.2 Selfview The term “Selfview” means the outgoing image. In a normal call using the main camera, this is the image of yourself. The Selfview button toggles the images between Far End, Selfview and Dual Video (if any). How to use Selfview: 1. Outside a call, pressing the S...
TANDBERG Maestro MXP 42 3.2.3 Picture Layout The layout of the screen can either be shown as Picture in Picture (PIP) or Picture outside Picture (POP) when displaying more than one video image. The behavior of the Layout button is dependent on the Picture Layout setting in Screen Settings . 3.2.3.1 ...
Administrator Settings 43 3.2.4 Mic Off To mute the microphone during a call, press the Mic off button. An on-screen indicator appears in the upper right corner when the microphone is off. In a call, if audio is detected, the on-screen symbol will start to flash. Pressing the Mic off button one more...
Administrator Settings 45 3.2.6 Number and Letter keys Pressing a number key when outside a call will bring up the call menu. When in a call, the number keys are used for Camera Presets. Press a number and go to the corresponding Camera Preset (see Camera Presets ). However, when accessing an input ...
TANDBERG Maestro MXP 46 3.2.7 Touch Tones To activate dialing touch tones during a call, press the Touch tones button. Otherwise the number keys will work as configured in the Number Key Mode, see Control Panel – Menu Settings – Number Key Mode. An indicator will let you know that Touch tones are en...
Administrator Settings 47 3.2.8 Presets and Extension Numbers When pressing a number key on the remote control, while in a call, the user can decide what shall happen. The system can be configured to act automatic or manual. While in a call, the user presses a number key to: • add another call • dia...
Administrator Settings 53 3.5.1 Place a Call The TANDBERG system can make both Video calls and Telephone calls . A Call Type selector button is placed to the right of the number entry field. The button shows if it is a video call (default) or a telephone call. Press the button to show a drop down li...
Administrator Settings 55 3.5.2 Add Call (Optional feature) Conference systems with built-in MultiSite can handle up to 6 video calls and 5 telephone calls simultaneously. It is possible to both set up a conference with many participants and also add participants during a conference. Set up a confer...
TANDBERG Maestro MXP 56 3.5.3 Call Settings The Call Settings specifies the quality of the call. Each call will be set up with the Default Call Settings if the settings are not altered. Usually it is not necessary for the user to alter the settings. The Call Settings are defined in Control Panel - C...
Administrator Settings 57 3.5.4 SIP Services SIP enables you to use the features Add Call and Transfer even if your system doesn’t have multipoint capabilities. To get the SIP Services available, you have to make a call using SIP as your Net. (See Call Settings) 3.5.4.1 Add Call You can add another ...
TANDBERG Maestro MXP 60 3.5.6 Dialing In From Outside the Enterprise Dialing in Without Being Registered to a TANDBERG Gatekeeper The feature enhancement enables dialing through a TANDBERG Gatekeeper without being registered to it. This makes it easy to call in from a video system outside the enterp...
Administrator Settings 61 3.6 Answer an incoming call How to answer an incoming call: To accept an incoming call, press the OK button or the green Call button on the remote control. How to reject an incoming call: To reject an incoming call, select the Reject icon and press the OK button, or pre...
TANDBERG Maestro MXP 64 3.8.1 Delay Standby for 1 hour Delay Standby for 1 hour postpones the system from entering standby mode for 1 hour. This function is useful when using the monitors for a local presentation to prevent the system from automatically blanking the monitors. It is also possible to ...
Administrator Settings 65 3.8.2 Delay Standby for 3 hours Delay Standby for 3 hours postpones the automatic standby mode for 3 hours. This function is useful when using the monitors for a local presentation to prevent the system from automatically blanking the monitors. It is also possible to postpo...
TANDBERG Maestro MXP 66 3.8.3 Do Not Disturb To prevent the system from accepting any incoming calls, activete the Do Not Disturb function. The caller will hear a busy tone when calling the system. The monitor will be black when Do Not Disturb is active, see figure below. This is useful when using t...
Administrator Settings 69 3.9.1 Call Log The Call Log lists Placed Calls, Missed Calls and Received Calls. That allows the user to see which calls that are made in the past. The lists contain a maximum of 30 numbers and the numbers are stored in these lists until the system is restarted. If the cont...
TANDBERG Maestro MXP 70 3.9.2 My Contacts My Contacts are the locally stored contacts on the system. This means that it is possible to add new contacts and edit or delete existing contacts. My Contacts can store up to 200 contacts. How to make a call using My Contacts: 1. Find the desired contact us...
TANDBERG Maestro MXP 72 3.9.2.1 Add New Contact The New Contact function is available from My Contacts . Add a new contact to My Contacts by: 1. Select the New Contacts button to open the New Contacts dialog box. 2. Enter Name by using the letter keys on the remote control. Input will automatically ...
Administrator Settings 73 3.9.2.2 New MultiSite Contact (Optional feature*) The New MultiSite Contact function is available from My Contacts . It is possible to pre-define the participants of a conference meeting as a MultiSite Contact. All participants in the MultiSite Contact will then be connecte...
Administrator Settings 75 3.9.2.3 Edit Contact The Edit Contact function is available from My Contacts . How to edit a contact in the Local Phone Book: 1. Select the contact that is to be edited. 2. Press the left arrow on the remote control, followed by the down arrow until the Edit Contact icon is...
TANDBERG Maestro MXP 76 3.9.2.4 Delete Contact The Delete Contact function is available from My Contacts . How to delete a contact: 1. Select the contact that is to be deleted. 2. Press the left arrow on the remote control, followed by the down arrow until the Delete Contact icon is selected. The De...
Administrator Settings 79 3.9.3.2 Search The phone book can contain an unlimited amount of global contacts. Using search makes it easier to find the wanted contact. How to search in the Global Phone Book: 1. Select the Search icon. 2. Enter search text in the dialogue box that appears and press the ...
TANDBERG Maestro MXP 80 3.9.3.3 Copy Contact to My Contacts The Copy Contact to My Contacts function is available from the Placed Calls, Missed Calls, Received Calls and Global Contacts folders, see Phone Book for details. It may be wise to copy contacts that are often used to My Contacts. Note that...
TANDBERG Maestro MXP 82 3.10.1 Move Camera It is possible to move the camera with the remote control or via the menu. Moving the camera directly with the remote control When the menu is hidden, the arrow keys will work on the camera. If the menu is displayed, press the Cancel button on the remote co...
Administrator Settings 83 3.10.2 Far End Control Far End Control allows you to control your conference partner’s camera. An example of when this feature could be especially helpful is if it is not possible to see what a participant at the far end is writing on their white board. Use Far End Control ...
TANDBERG Maestro MXP 84 3.10.3 Camera Presets Use camera presets to easily vary between predefined near end camera angles. This is useful when pictures from many different camera angles have to be sent to the far end. E.g. in a meeting there is a white board, a PC and a small meeting table. Use came...
Administrator Settings 85 3.10.4 TANDBERG Tracker How to save presets for the TANDBERG Tracker: 1. Select which camera preset is to be used on the TANDBERG Tracker. 2. Move the camera to the desired position to store on the tracker. 3. Select Move Camera - Save New Preset in the menu. 4. All camera ...
TANDBERG Maestro MXP 86 3.10.5 Picture Control Focus, Brightness and White balance are set for auto focus, auto brightness and auto white balance by default. If you need to set focus, brightness and white balance manually, go to Picture Control in the Camera Control menu. Focus Auto Auto focus conti...
TANDBERG Maestro MXP 88 3.10.6 Camera Tracking Through Camera Tracking and the use of two or three microphones, the camera can automatically position itself on the current speaker. Before using camera tracking, the camera positions used must be stored at Preset 7 (Mic1), Preset 8 (Mic2) and/or Prese...
TANDBERG Maestro MXP 90 3.11.1 Presentation Key The quickest way to show a presentation is to use the presentation key on the remote control. The presentation key is used to start and stop a presentation. The presentation key will display PC (default*). When holding the presentation key for 1 second...
Administrator Settings 91 3.11.2 Presentation Menu The Presentation menu offers you all available video sources; Main Camera, PC, Document Camera, VCR, AUX and VNC. All these sources can be used as Main Video Stream or Dual Video Stream (Duo Video / H.239). Not all systems has all video sources avai...
Administrator Settings 93 3.11.4 PC Soft Presenter and VNC (Optional feature) PC SoftPresenter is used to display PC images on your system without using a VGA cable (PC Presenter). The system and your PC must be connected to the same LAN. In addition, VNC (Virtual Network Computing) server software ...
TANDBERG Maestro MXP 94 3.11.5 Dual Stream (DuoVideo TF /H.239) (Optional feature - not available on all systems) With Dual Stream you have the opportunity to show two different live video streams simultaneously, main video and one additional source. This is handy when showing a presentation. You se...
Administrator Settings 95 3.11.6 Take New Snapshot The system can take a snapshot of your live video. Snapshot is handy when you are in a call with a system that does not support Dual Stream. Use Snapshot to show a snapshot of your presentation and continue the meeting with main camera. How to use s...
TANDBERG Maestro MXP 96 3.11.7 Display Snapshot The system stores the last sent or received Snapshot. The snapshot is deleted automatically after the call. How to display snapshots: 1. To view a stored snapshot, first choose the Snapshot header. 2. Select Display Snapshot in the Presentation menu. 3...
TANDBERG Maestro MXP 100 3.12.1 Request Floor and Release Floor When requesting floor, your video will be broadcasted in full screen to all other participants in the conference. Request Floor is useful when you want to speak or display something in front of all participants. Release Floor when you a...
Administrator Settings 101 3.12.2 Conference Layout (Only supported by TANDBERG MultiSite*) With a TANDBERG MultiSite you can choose between the layouts: Auto Split, 4 Split, 5+1 Split and Voice Switched view. Auto Split displays all participants on the screen simultaneously. 4 Split displays the 4 ...
TANDBERG Maestro MXP 102 3.12.3 Terminal Names Choose Terminal Names to see a list of the participants of the MultiSite conference. Press Cancel to go back.
Administrator Settings 103 3.12.4 Chair Control (Not supported by TANDBERG MCU or MultiSite) As chairman, you have access to more MultiSite Services. Select Chair Control to assume the role of chairman of the conference. Select Release Chair to end the role as chairman. A Chair indicator appears whe...
TANDBERG Maestro MXP 104 3.12.5 Assign Floor and Release Floor from Participant Assign Floor allows the chairman to select which of the conference participants are to be broadcasted to all other participants.
Administrator Settings 105 3.12.6 View Site and End View (Not supported by TANDBERG MCU or MultiSite) View Site allows you to view any participant in the conference regardless of who has the floor and chair. Choose End View to go back to normal.
TANDBERG Maestro MXP 106 3.12.7 Disconnect Participant Disconnect Participant allows the chairman to disconnect any participant in the conference. In a multipoint call, this is equivalent to disconnecting a participant from the end call menu.
Administrator Settings 107 3.12.8 Terminate Meeting Terminate Meeting allows the chairman to terminate the conference altogether. In a MultiSite call, this is equivalent to pressing End All Calls from the end call menu.
Administrator Settings 111 4 Control Panel The Control Panel contains the features: User Guide Diagnostics Audio Demo Restart Settings* Settings: General Call Quality Security Menu Settings Audio Network Presentation Settings Video Restore Default Settings NOTE: If Admini...
TANDBERG Maestro MXP 114 4.2.1 System Information Select System Information to view system numbers, line status, software version, hardware serial number and other useful information. Press arrow key up and down to scroll in the System Information list. System Information contains: System Name My IS...
Administrator Settings 115 4.2.2 Channel Status Comprehensive information about the call progress is available through the Channel Status window. This window indicates the various stages each B-channel goes through whilst establishing a connection. Status - BRI Comments Idle Calling Connected Sync A...
TANDBERG Maestro MXP 118 4.2.4 System Selftest The system performs a check to determine internal hardware integrity. System Selftest is useful when you want to check if your network connection is active.
TANDBERG Maestro MXP 124 4.2.6 IP Address Conflict Check The system will give a warning if there is an IP conflict. The user may initiate this check by selecting IP Address Conflict Check.
Administrator Settings 129 5 System Settings The Control Panel contains all the settings of the system. Making changes to the settings will change the behavior of the system. It is recommended to password protect the access to the settings to prevent occasional users from making crucial changes to t...
TANDBERG Maestro MXP 130 5.1 General Settings When installing the system, go through the General Settings menu to ensure that you have the right settings for your system, see System Configuration. General Settings contain: Language System Name / International Name * Auto Answer Phone Book Se...
TANDBERG Maestro MXP 132 5.1.2 System Name System Name identifies the system: On the welcome page. During an MCU conference call. When using the Web-interface. When the codec is acting as an SNMP Agent. Towards a DHCP server. H323 ID. Other systems can call in using this name instead of ...
TANDBERG Maestro MXP 134 5.1.4 Auto Answer The auto answer setting decides whether an incoming call is put through automatically or manually. On The system will automatically answer all incoming calls. On+Mic Off The system will automatically answer all incoming calls and switch the microphone off w...
Administrator Settings 135 5.1.5 Phone Book Settings Corporate Directory On The Corporate Directory is available in the menu. Off The Corporate Directory is hidden from the menu and is unavailable for users. IP address Enter the IP address of the management system that provides the Phone Book. Path ...
TANDBERG Maestro MXP 136 5.1.6 External Services Settings External Services On When set to On External Services are available. Off When set to Off External Services are unavailable. IP address Enter the IP address of the service provider for External Services. Path Enter the Path to the External Ser...
Administrator Settings 145 5.1.9 Software Options The system requires a valid option key to activate MultiSite and/or Presenter functionality. In order to activate additional bandwidth, you need to enter a bandwidth key. A restart of the system is required after entering a new option and/or bandwidt...
TANDBERG Maestro MXP 146 5.1.10 Date and Time Settings NTP IP This is the NTP time server address from which the system can get updated time information. See IP Services for more details. Auto The NTP IP will be provided by the DHCP server. Manual The NTP IP address is set manually. IP Address The I...
TANDBERG Maestro MXP 148 5.2.1 Input Editor Language When the Input Editor Language is set to Chinese, Korean or Japanese the user will be able to enter Chinese / Korean / Japanese characters into an input field like the System Name or Phone Book, using the remote control.
Administrator Settings 149 5.2.2 Menu Timeout in Call The Menu appears on the bottom line of the screen. Set Menu Timeout In Call to On if you want the menu to time out automatically when you are in a call. On The menus will time out automatically after 15 seconds if there is no activity on the remo...
TANDBERG Maestro MXP 150 5.2.3 Menu on TV The Menu on TV setting decides if the menu shall be displayed on the TV screen or not. For optimal layout of the menu, Menu on TV should be Off if Menu on PC is On and vice versa. On The menu is available on the TV screen. Off The menu is not available on th...
TANDBERG Maestro MXP 152 5.2.5 Balloon Help It is possible to enable / disable the balloon help window. On Choose On if you want help text windows to appear. Off There will be no help text window.
Administrator Settings 153 5.2.6 Number Key Mode When pressing a number key on the remote control, while in a call, the user can decide what shall happen. The system can be configured to act automatic or manual. While in a call, the user presses a number key to: • add another call • dial extension n...
TANDBERG Maestro MXP 156 5.2.7 Administrator Password It is recommended to put an Administrator Password on the system. The Administrator Password can be maximum 5 digits long. The Administrator Password dialog box will pop up when you choose Settings from the Control Panel. This will prevent occasi...
Administrator Settings 157 5.2.8 Kiosk Mode Settings Kiosk Mode In Kiosk Mode the system is set to a simplified state where it can be controlled with just the four arrow keys and OK. You will get a simplified on-screen menu with only basic functionality available: make calls (using predefined cont...
Administrator Settings 163 5.3 Presentation Settings Presentation Settings contain: Presentation Start H.239 Startup Video Source Presentation Source Snapshot Source Auto-Display Snapshot PIP Placing Presentation Rate VNC Settings
TANDBERG Maestro MXP 164 5.3.1 Presentation Start If your system has Dual Stream capabilities, you can show two video streams at the same time (see also Dual Stream ). Presentation Start is Auto by default. This means that you will start Dual Stream (a second video stream) automatically when startin...
TANDBERG Maestro MXP 166 5.3.3 Startup Video Source The Startup Video Source is the video source on display when the system wakes up from standby mode. If you use Main Camera as start up source, the system will start with Main Camera every time the system wakes up from standby, regardless of what th...
Administrator Settings 167 5.3.4 Presentation Source The Presentation Source is connected to the Presentation button on the remote. Pressing the Presentation button will put the Presentation Source on display. Presentation Source is PC by default*. You can change the Presentation Source to any video...
Administrator Settings 169 5.3.6 Auto-Display Snapshot Select Auto to automatically display a received snapshot. Turn Auto-Display Snapshot Manual if you wish not to have them displayed on the screen when they are sent or received. The snapshots will be sent and received, but not displayed. With Aut...
TANDBERG Maestro MXP 170 5.3.7 PIP Placing PIP Placing lets you decide where the PIP shall appear. You can of course move the PIP with the Layout button on the remote anytime. Top Right PIP is placed in the Top Right corner. Bottom Right PIP is placed in the Bottom Right corner. Bottom Left PIP is p...
Administrator Settings 171 5.3.8 Presentation Rate When setting up a call with H.323 the bandwidth can be controlled by the user. The Presentation Rate is expressed in percent of the Call Rate and shall reflect the H.323 Presentation Rate settings of the sender. The settings are 25%, 50% and 75% of ...
TANDBERG Maestro MXP 174 5.4.1 Video Algorithm The system will automatically select the best video algorithm based on the video source and the capabilities of the remote system. Use this menu to disable video algorithms in case you have interoperability issues calling other systems. H.264 Bandwidth ...
Administrator Settings 177 5.4.4 Natural Video Choosing Natural Video will enable 60 fields* per second true interlaced picture for high motion video. The use of Natural Video requires the H.263+ and H.263++ video protocols. Natural video will be disabled in H.323 MultiSite calls and in H.320 Contin...
Administrator Settings 179 5.4.6 Video Quality The different video sources need different Video Quality Settings. Main Camera, VCR, AUX and Split Screen have Motion as default. PC, Document Camera and VNC have Sharpness as default. Motion* Optimized for smooth motion video (CIF/SIF or w288p for low ...
TANDBERG Maestro MXP 196 5.5.6 Alert Tones and Volume Video Call Alert Tone and Telephone Alert Tone To help distinguish between incoming video calls and ordinary telephone calls, it is recommended to use different ringing tones for video calls and telephone calls. Alert Volume You may change the vo...
Administrator Settings 197 5.5.7 Graphical View Graphical View The graphical view is a visual presentation of the audio inputs and audio outputs. • The Inputs + Far End In are listed on the left, showing the name of the input sources. • The outputs + Far End Out are listed on the bottom, showing the...
TANDBERG Maestro MXP 200 5.6.2 MCU Status Line On The MultiSite / MCU / DuoVideo indicators will be displayed and provide information about the conference. Off The MultiSite / MCU / DuoVideo indicators will not be displayed. Auto The MultiSite / MCU / DuoVideo indicators will be displayed for a few ...
Administrator Settings 201 5.6.3 Floor to Full Screen When "Floor to Full Screen" is enabled, someone who requests floor will be seen by all participants as full screen. When "Floor to Full Screen" is "Off", someone who request floor in a MultiSite conference using the 5+1 la...
TANDBERG Maestro MXP 202 5.6.4 Web Snapshots The system is able to generate JPEG snapshots and provide them when requested (as ‘http get’ or via ftp). See Appendix 6 for descriptions of the possible snapshot files. On Snapshots generation is enabled. Off Snapshots generation is disabled. Note that w...
Administrator Settings 203 5.6.5 MultiSite Picture Mode MultiSite* Picture Mode determines the default layout of a MultiSite call. Available layouts are: Auto Split, 4 Split, 5+1 Split, and Voice Switched. You can change the layout during a call using the layout option in MultiSite Services. Auto Sp...
TANDBERG Maestro MXP 208 5.7.2 Encryption Mode Auto The system will try to use the most secure encryption - AES, dependent on the capabilities of the other sites. For sites that do not support AES encryption, DES encryption will be tried. AES The system will try to use AES with 128 bits encryption w...
TANDBERG Maestro MXP 210 5.7.4 Camera Standby Mode There is a setting to the Security menu called Camera Standby mode On (default)/Off. When Camera Standby mode is On, the camera turns away when standby is activated. When the system is activated the camera turns back to normal position. On The camer...
Administrator Settings 213 5.8.1.1 ISDN-BRI Settings To make sure your system will work properly using ISDN-BRI, make the following settings: 1. Set ISDN switch type 2. Enter ISDN line numbers (+ SPIDs if required) 3. Disable unused lines Some software versions do not support 6 ISDN lines, therefore...
TANDBERG Maestro MXP 214 Advanced ISDN Settings Sub address Using a sub address enables you to connect up to eight ISDN terminals to the same ISDN telephone number and line. The terminals are addressed by using different sub addresses. To call a terminal with a sub address, separate the ISDN telepho...
Administrator Settings 215 5.8.1.2 ISDN-PRI Settings To make sure your system will work properly using ISDN-PRI, configure the following settings: 1. Set PRI switch type 2. Enter PRI line number Note that the T1 format is predefined to ESF and the line code is B8ZS. This is not configurable. Number ...
TANDBERG Maestro MXP 216 Example: Max Channels may be used for PRIs that are provisioned for a lower number of channels. High Channel, Low Channel and Search may be used for PRIs provisioned with specific requirements for B-channel usage. In the example above, the system will start searching for ava...
Administrator Settings 225 DNS Settings DNS Server 1-5 DNS Server defines the network addresses for DNS servers. Up to 5 addresses may be specified. If the network addresses are unknown, please contact your administrator or Internet Service Provider. DNS Domain Name DNS Domain Name is the default do...
Administrator Settings 227 Gatekeeper Settings Gatekeeper Discovery Auto The system will automatically try to register to any available gatekeeper. If a gatekeeper responds to the request sent from the codec within 30 seconds this specific gatekeeper will be used. This requires auto discovery on the...
Administrator Settings 229 CallManager Settings CallManager IP This is the CallManager IP-address that is used if you specify H.323 Call Setup: CallManager.
TANDBERG Maestro MXP 230 Advanced H.323 Settings The Advanced H.323 Settings only have an effect if they are supported by your IP infrastructure. NAT NAT, Network Address Translation, is used when a PC and a videoconferencing system are connected to a router with NAT support. NAT support in the vide...
Administrator Settings 231 5.8.2.3 SIP Settings Mode On Setting the SIP mode to on will enable the system for incoming and outgoing SIP calls. Off Setting the SIP mode to off will disable incoming and outgoing SIP calls from the system. Display Name The Display name part of the SIP Address (URI) is ...
TANDBERG Maestro MXP 232 The Server Address is the manually configured address for the outbound proxy and registrar. It is possible to use a fully qualified domain name, or an IP address. The default port is 5060 for TCP and UDP, but another one can be provided. Server Address: <text field> Ex...
Administrator Settings 233 Draft-ietf-avt-rfc2032-bis-06.txt - Draft for advanced video signaling including resolution and mpi. RFC 2190 RTP Payload Format for H.263 Video Streams RFC 2429 RTP Payload Format for the 1998 Version of ITU-T Rec. H.263 Video (H.263+) Draft-ietf-avt-rfc2429-bis-0...
Administrator Settings 239 5.8.3 Network Profiles This menu consists of 7 network profiles; a prefix and a suffix can be added for each profile. If you add a prefix/suffix to a profile, this prefix/suffix will automatically be added in front/back of the number being dialed. Example: 0 is added as a ...
TANDBERG Maestro MXP 240 5.8.4 Data Port The system provides up to two standard RS232 serial ports to allow a computer to be connected for data transfer and control purposes. Note that when connecting to a PC the connecting cable must be a straight through RS232 cable. Baud Rate, Parity, Data bits a...
Administrator Settings 241 5.8.5 Restore Default Settings Restore Default Settings will restore all system settings. Note that this will not affect your Call Directory information, Network Type, Line Setup numbers or your SPID numbers.
6 Peripheral Equipment Using the optional peripheral devices outlined in this chapter and the many others available, you will be able to build your own applications for use with the system, thereby better integrating the system into your business environment. This chapter will explain how to connect...
Peripheral Equipment 255 6.1.4 Data port The data port(s) are implemented as Data Communications Equipment (DCE). The connectors used are female 9-pin D-subs. NOTE! Data port 2 is used by both Wave II Camera and Precision HD Camera and has different pin-out scheme for the different use. The TANDBERG...
TANDBERG Maestro MXP 258 6.4 Additional Cameras Extra fixed Cameras You can connect extra fixed cameras to your system, for example, a whiteboard camera. Connect the video output of the additional camera to one of the available Video inputs on the system. Multiple controllable Cameras Attaching mult...
Peripheral Equipment 259 6.5 Additional Microphones If your environment is such that you require more than one microphone for your room, e.g. you have a whiteboard at a distance from your table microphone, it is possible to connect additional microphones to your system. See Appendix 4 for more infor...
Peripheral Equipment 261 6.6 The TANDBERG DNAM and Speakers TANDBERG 6000 MXP Profile, TANDBERG 6000 MXP, TANDBERG 7000 MXP, TANDBERG 8000 MXP and TANDBERG Maestro The TANDBERG Digital Natural Audio Module, DNAM*: The DNAM audio system is built on two specially designed and separate modules; the DNA...
TANDBERG Maestro MXP 264 TANDBERG 3000 MXP Profile: The TANDBERG Mini-DNAM*: The Mini-DNAM audiosystem is built on two specially designed and separate modules; the Mini-DNAM amplifier and the Mini-DNAM loudspeaker cabinet. The Mini-DNAM loudspeaker cabinet is stereo-configured and based on two versi...
Peripheral Equipment 265 6.7 Stereo Speaker Kit Note that the following applies only for systems with a stereo S/PDIF output. The Stereo Speaker Kit provides an pair of floor-standing loudspeakers in addition to the built-in DNAM . Using these speakers will enable stereo functionality in your system...
Peripheral Equipment 269 6.10 XGA Monitors and Projectors (Optional) Some TANDBERG systems can be delivered with optional single or dual TV/XGA monitors. It can also be connected to any DVI/VGA/PAL or NTSC display. Note that this requires a system with minimum one DVI-I output.
Peripheral Equipment 271 6.12 Digital Monitor Power Management DMPM is monitor power management applied over the digital DVI interface. TANDBERG supports DMPM in software F2 and above. Six monitor power states are defined. Monitor On Power state Transmitter (TANDBERG codec) and receiver (Monitor) ar...
TANDBERG Maestro MXP 272 6.13 Extended Display Identification Data (EDID) Extended Display Identification Data (EDID) is a VESA standard data format that will allow the system to communicate its capabilities, including vendor information like the supported VGA-formats and frequency range limits to a...
7 Appendices Appendices: Appendix 1: Technical Specification Appendix 2: Bandwidth Information Appendix 3: Environmental considerations Appendix 4: Guidelines for setting up rooms for video meetings Appendix 5: Security Appendix 6: Using the file system Appendix 7: Web Interface Appe...
Glossary 275 Appendix 1: Technical Specifications Technical Specification BANDWIDTH H.320 up to 2 Mbps H.323 up to 4 Mbps point-to-point SIP up to 4 Mbps Up to 6 Mbps total MultiSite bandwidth FIREWALL TRAVERSAL TANDBERG ExpresswayTM Technology Auto NAT H.460.18, H.460.19 Firewall Traversal VIDEO ST...
TANDBERG Maestro MXP 278 Appendix 2: Bandwidth Information for TANDBERG Endpoints Bandwidth information for TANDBERG endpoints Model 8000MXP, 7000MXP 6000MXP, Maestro Bandwidth Point to point ISDN / IP Standard: 768 / 3072 Option: 1920 / 4096 Standard: 768 / 3072 Option: 1920 / 4096 MultiSite Total:...
TANDBERG Maestro MXP 280 Appendix 3: Environmental Considerations Environmental considerations This section explains how to carry out basic adjustments and simple tests to ensure that you send and receive the best possible image and audio quality when using your system. Iris control and lighting By ...
Glossary 281 Appendix 4: Guidelines for Settings up Rooms for Video Meetings Guidelines for setting up rooms for video meetings The following are a set of guidelines to consider when either building a video meeting room, or using an existing room for video meetings. Lighting: Low Contrast desired ...
TANDBERG Maestro MXP 282 Appendix 5: Security Security The system has several features both to protect from unauthorized use and system access: Access Code: When Access Code is enabled, the user will be asked to enter an access code before he/she is able to make a call. The system will verify if the...
Glossary 285 Appendix 6: Using the File System Using the file system It is possible to access a file system within the TANDBERG system by using ftp: DOS-window: ftp <IP-address of system>, or Web-browser: ftp:// <IP-address of system> Description of the different files: all.prm all setti...
TANDBERG Maestro MXP 286 Appendix 7: Web Interface Web Interface It is possible to access and maintain the system remotely via a local area network (LAN) using a standard Web-browser. Connect your system to a LAN with a Network cable. How to configure your system for web interface: 1. Open Administr...
Glossary 287 Appendix 8: Connecting the System to PRI/T1 (Not available on all TANDBERG systems) Connecting the system to PRI/T1 Using CSU adapter Connecting the system to the ISDN network via the E1/T1-interface using an Adtran T1 ESF CSU ACE or equivalent CSU, will allow up to 1.54 Mbps connection...
TANDBERG Maestro MXP 288 Appendix 9: Connecting the System to Switched 56 Network Connecting the system to the Switched 56 network Using Telesync TS-256 SW56/ISDN adapter Connecting the system to the SW56 network using a Telesync Adapter is described below. There are different Telesync Adapters for ...
Glossary 291 Appendix 11: TANDBERG Cameras TANDBERG Precision HD Camera (Available to TANDBERG 8000 MXP, 6000 MXP Profile, 3000 MXP Profile*, Maestro MXP and Edge 75/85/95 MXP) Pin-outs and Connectors
Glossary 295 (Not available with set top systems) WAVE II Camera Pinouts and Connectors 8-PIN RJ (shielded modular jack): This connector is used for the power and control signals to the main camera. Pin-8 +12V (presence when connected in daisy chain) Pin-7 GND Pin-6 GND Pin-5 RXD (in) Pin-4 TXD (out...
Glossary 301 Appendix 13: Cisco Call Manager Registration Cisco CallManager registration Configuring an H.323 client on the CallManager 4.0 The registration of a H.323 client in CallManager is supported on the CallManager (CCM) 4.0 software and forward. 1. To configure the CallManager with an H.323 ...
TANDBERG Maestro MXP 302 Appendix 14: Diagnostic Tools for IP Diagnostic Tools for IP To use these tools, will require using a PC and setting up a telnet session towards the system. Q.931 To show Q.931 trace during a call you need to issue the command ‘syslog on’. One can get traces for RAS, Q.931 a...
TANDBERG Maestro MXP 304 Appendix 15: System Upgrade System Upgrade Before starting the software upgrade of the TANDBERG MXP system, please make sure to have the new software file, (for instance s050000F30.pkg) and the Release Key for this software available. Your TANDBERG Partner will provide this ...
Glossary 309 Appendix 16: Declaration of Conformity Declaration of Conformity EC DECLARATION OF CONFORMITY MANUFACTURER: TANDBERG Telecom AS PRODUCT NAME: TANDBERG Maestro TYPE NUMBER: TTC60-06 DESCRIPTION: Video Conferencing Equipment This product complies with Commission Directives: LVD 73/23/EE...
TANDBERG Maestro MXP 310 Appendix 17: Dimensions Dimensions
Glossary 313 Appendix 18: Protocols Supported PROTOCOLS SUPPORTED TCP/IP - Transmission Control Protocol/Internet Protocol A set of networking protocols that provides connectivity over LAN/WAN to any network computer. HTTP - Hypertext Transfer Protocol A protocol used to transfer information on the ...
Glossary 315 Appendix 19: Cable Specifications TANDBERG MXP and Classic Endpoints that support External Network External Network Pinout With respect to signals on the NET port: • For balanced signals a “0”=low voltage is defined as terminal A positive with respect to terminal B. • For unbalanced sig...
Glossary 323 8 Glossary # 199 AV1: External input for the TANDBERG/LOEWE monitor. 2nd monitor: The second monitor of your videoconferencing system. The second monitor is normally placed on the right side of the first monitor. 4CIF: 4 times CIF, 704x576 pixels 4SIF: 4 times SIF, 704x480 pixels A AACL...
TANDBERG Maestro MXP 332 9 Index A Access Code....................................114, 137 Add Another Call........................................55 Additional microphone .............................259 Administrator Password...........................156 Alert Speaker ...............................
TANDBERG Manuals
-
TANDBERG 7000
Manual
-
TANDBERG EX90
Manual
-
TANDBERG E5740
Manual
-
TANDBERG D11624
Manual
-
TANDBERG MXP
Manual
-
TANDBERG Intern MXP
Manual
-
TANDBERG D13922.06
Manual
-
TANDBERG 2000MXP
Manual
-
TANDBERG 1500MXP
Manual
-
TANDBERG 880 MXP
Manual
-
TANDBERG MSE 8510
Manual
-
TANDBERG D14306.01
Manual
-
TANDBERG Utility
Manual
-
TANDBERG 6000 MXP
Manual
-
TANDBERG D1440902
Manual
-
TANDBERG D13751.01
Manual
-
TANDBERG D12809
Manual
-
TANDBERG D1392602
Manual
-
TANDBERG MPS 200
Manual
-
TANDBERG TC2.1
Manual