Page 2 - Table of Contents; CONNECTING TO THE DATA PORT COMMAND INTERFACE THROUGH THE RS-
TANDBERG GW Data port Command Interface User Guide 2 Table of Contents 1. INTRODUCTION........................................................................................................................... 3 2. CONNECTING TO THE DATA PORT COMMAND INTERFACE THROUGH THE RS- 232 PORT. ................
Page 3 - Introduction; The
TANDBERG GW Data port Command Interface User Guide 3 1. Introduction The TANDBERG GW Data port Command Interface User Guide contains guidelines on how to use the textual command interface supported by the GW. The Data port Command Interface can be accessed through Telnet via the LAN interface or thr...
Page 4 - Hardware and Cabling; TANDBERG
TANDBERG GW Data port Command Interface User Guide 4 2. Connecting to the Data port Command Interface through the RS-232 port. The RS-232 port is a 9-pin, female, D-sub connector located on the front of the GW. The port is configured as a DCE (Data Communications Equipment). The RS-232 port is defau...
Page 5 - Troubleshooting
TANDBERG GW Data port Command Interface User Guide 5 2.2. Troubleshooting If communication cannot be established between the PC/terminal and the TANDBERG GW’s Data port the following should be checked: • Verify that the serial cable is a straight through 9-pin to 9-pin cable • Confirm that the confi...
Page 6 - Connecting to the Data port Command Interface using Telnet; The TANDBERG 3GW has one LAN port.
TANDBERG GW Data port Command Interface User Guide 6 3. Connecting to the Data port Command Interface using Telnet The TANDBERG 3GW has one LAN port. The GW’s Telnet server provides access to the Data port Command Interface through a 10/100 base T network interface supporting the TCP/IP protocol. Wh...
Page 7 - The TANDBERG 3G Gateway Commands; parameters
TANDBERG GW Data port Command Interface User Guide 7 4. The TANDBERG 3G Gateway Commands 4.1. Introduction Typing ‘ ? ’ or ‘ help ’ when connected to the Data Port Command Interface will return a list of valid commands. The commands are used to control the functions of the 3G Gateway. A command may ...
Page 8 - Parameter Configuration Commands; , otherwise the GW returns; ERROR; OK; The commands
TANDBERG GW Data port Command Interface User Guide 8 • User Commands, Xcom. Parameter Configuration Commands are commands that set a system parameter to a specific value. E.g.: The command Xconf telnet mode: "on" enables telnet access on the gateway. If the command is syntactically correct t...
Page 9 - System Configuration Commands; Authentication Mode; NOTE! Authentication Password is write only.; IP; NOTE! The GW needs to reboot before the changes will take effect
TANDBERG GW Data port Command Interface User Guide 9 4.2.1. System Configuration Commands Command: Description: H323Gatekeeper Sets gatekeeper parameters. NOTE! H.323 services must be set before the GW can be registered to a gatekeeper. H323Gatekeeper Address <IPAddr> or H323Gatekeeper Authent...
Page 10 - Assignment; NOTE! The GW needs to reboot before the changes will apply; Ethernet
TANDBERG GW Data port Command Interface User Guide 10 • DNS Server: Number identifying one of 5 DNS servers which can be configured. If this parameter is omitted the command applies to the first configuration (1). sub-commands: • Assignment : Selects between DHCP (Dynamic Host Configuration Protocol...
Page 11 - NOTE! Changes become effective after reboot.
TANDBERG GW Data port Command Interface User Guide 11 Within ISDN different bearer capabilities are used to signal the type of date (Voice, Data, H320, H324M), which is used by switches and other equipment to determine what to do with the data or the call (compand neglect etc). • IncomingBearerCapab...
Page 13 - Name, sets the name of the 3G Gateway; SystemUnit
TANDBERG GW Data port Command Interface User Guide 13 sub-commands • Name, sets the name of the 3G Gateway • Password, sets the password of the 3G gateway Example of SystemUnit feedback: *c xConfiguration SystemUnit Name: ""
Page 14 - General GW Commands; SystemLoad
TANDBERG GW Data port Command Interface User Guide 14 4.2.2. General GW Commands Command: Description: Gateway This command is used to configure the 3G gateway dialling rules, like for example direct inward dialling, H323 call prefixes and dial in numbers. It is possible to define 100 services, each...
Page 16 - Key; or; Mode; : If Mode = On the 3G Gateway is registered with the Proxy; SIP
TANDBERG GW Data port Command Interface User Guide 16 NOTE! The GW needs to reboot before the changes will take effect . Options [1 .. 64] Key: <S: 0, 90> --- sub-commands: • Key : Option key for e.g. BRI, PRI or SS7 trunks. Example of Options feedback: *c xConfiguration Options 1 Key: "11...
Page 17 - LinkSet Link Timeslot:
TANDBERG GW Data port Command Interface User Guide 17 LinkSet [1 .. 2] Link [1 .. 2] Timeslot: <1 .. 31> LinkSet [1 .. 2] Link [1 .. 2] SLC: <0 .. 15> Trunk [1 .. 4] Mode: <On/Off> Trunk [1 .. 4] DPC: <0 .. 16383> Trunk [1 .. 4] CircuitIdentificationCode: <0 .. 16383> R...
Page 18 - in the 3G Gateway User Manual.
TANDBERG GW Data port Command Interface User Guide 18 in the 3G Gateway User Manual. Example of SS7 feedback: *c xConfiguration SS7 OPC: 0 *c xConfiguration SS7 NetworkIndicator: National0 *c xConfiguration SS7 Law: ALaw *c xConfiguration SS7 LinkSet 1 Mode: Off *c xConfiguration SS7 LinkSet 1 DPC: ...
Page 20 - : If Mode = On the 3G Gateway is registered with 1 or 2 video; VideoPortal
TANDBERG GW Data port Command Interface User Guide 20 VideoPortal Registers the 3G Gateway with the VideoPortal NOTE! The GW needs to reboot before the changes will take effect . Mode <On/Off> or System [1 .. 2] IP Address <IPAddr> --- sub-commands: • Mode : If Mode = On the 3G Gateway i...
Page 21 - System Status Commands
TANDBERG GW Data port Command Interface User Guide 21 4.2.3. System Status Commands Command: Description: SystemUnit Displays information regarding the physical system SystemUnit Status format: <ProductType> <Uptime> <Software Version> Name> ReleaseDate> Configuration Telepho...
Page 24 - ExternalManager; Example of; BRI; feedback
TANDBERG GW Data port Command Interface User Guide 24 Example of ExternalManager feedback: * s ExternalManager: Address: "" Protocol: HTTP URL: "tms/public/external/management/SystemManagementService.asmx" *s/end BRI [1..4] Displays the status of the BRI lines BRI Parameters: • BRI [...
Page 25 - Feedback; Indicates if there is HTTP feedback registered for a given; GatewayCall; the status of the ISDN line
TANDBERG GW Data port Command Interface User Guide 25 Channel 15 (type=BChannel, status=Idle): / Channel 16 (type=DChannel, status=NA): / Channel 17 (type=BChannel, status=Idle): / Channel 18 (type=BChannel, status=Idle): / Channel 19 (type=BChannel, status=Idle): / Channel 20 (type=BChannel, status...
Page 26 - the status of the different session legs.
TANDBERG GW Data port Command Interface User Guide 26 Example of GatewayCall feedback: *s GatewayCall 1 (status=Inactive): / *s/end OK *s GatewayCall 1 (status=Active): CallRef 1: 1 CallRef 2: 2 *s/end OK xstat gatewaycall 1 *s GatewayCall 1 (status=Active): CallRef 1: 1 CallRef 2: 3 *s/end OK Syste...
Page 27 - Debug Commands; DefaultValuesSet
TANDBERG GW Data port Command Interface User Guide 27 LastCorrection: 1 *s/end 4.2.4. Debug Commands Command: Desription: Syslog Enables a real-time log of Bonding, H.221 and H.323, H324m, ISDN, RTSP, IVider, SIP and IVider Engine activity. Note! Logging via the serial port is limited by the speed o...
Page 29 - OptionKeyDelete; Command used to delete option keys.; ServiceEntryDelete; Command used to delete services from the 3G Gateway.; ServiceEntrySwap; Command used to swap service numbers.; help; The special command
TANDBERG GW Data port Command Interface User Guide 29 Example: Xcommand OptionKeyAdd 115201P1-1-6A96DAA4 *r Result (status=OK): / *r/end OK OptionKeyDelete Command used to delete option keys. Parameters: • Key(r): <S: 0, 90> option key Example (Delete Option Key nr. 1): xCommand OptionKeyDelet...
Page 30 - Examples
TANDBERG GW Data port Command Interface User Guide 30 or: xfeedback list - (note: deregistration with index=0 will deregister all registered expressions) Examples : "xfeedback register status/call" - to monitor call changes "xfeedback register status/call--" - to monitor only call st...
Page 32 - Index Commands; SSH
TANDBERG GW Data port Command Interface User Guide 32 4.3. Index Commands boot, 27 BRI [1..4], 24 Call [1..90], 26 DefaultValuesSet, 27 E1, 11 Ethernet, 10 , 22 externalManager, 15 ExternalManager, 23 Feedback [1 3], 25 FeedbackDeregister, 28 FeedbackRegister, 27 , 29 Gateway, 14 GatewayCall [1..30]...