TANDBERG 7000 MXP - Manuals
TANDBERG 7000 MXP – Manual in PDF format online.
Manuals:
Manual TANDBERG 7000 MXP
Summary
User Manual iii Trademarks and Copyright All rights reserved. This document contains information that is proprietary to TANDBERG. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, electronically, mechanically, by photocopying, ...
TANDBERG 7000 MXP vi Environmental Issues Thank you for buying a product which contributes to a reduction in pollution, and thereby helps save the environment. Our products reduce the need for travel and transport and thereby reduce pollution. Our products have either none or few consumable parts (c...
TANDBERG 7000 MXP viii Operator Safety Summary Operator Safety Summary For your protection please read these safety instructions completely before you connect the equipment to the power source. Carefully observe all warnings, precautions and instructions both on the apparatus and in these operating ...
User Manual xi Table of Contents 1 Introduction ............................................................................................................................... 1 1.1 At a Glance .............................................................................................................
1 Introduction The TANDBERG 7000 MXP provides high-end performance features, large monitors and precision audio. This creates a collaborative meeting environment for medium to large-sized meeting rooms. Users can dial in from a video system outside the enterprise without being registered to a gateke...
2 Installation Precautions: Never install communication wiring during a lightning storm. Never install jacks for communication cables in wet locations unless the jack is specifically designed for wet locations. Never touch uninstalled communication wires or terminals unless the telephone line ...
TANDBERG 7000 MXP 12 2.1 Unpacking and Mounting 1 Unpacking The TANDBERG 7000 MXP is delivered in one transport case with all components inside as shown in figure 1: Figure 1 Foot Column Monitor Frame with built-in LCD monitors Monitor Rear Cover W.A.V.E. II Camera Accessories box which ...
Installation 15 2.2 Connecting Cables 1. Power cable Connect the system power cable to the correct country variant of the power cable. Connect this cable to an electrical distribution socket. 2. Microphone cable Connect the microphone cables to the microphones. 3. DNAM Audio Module - audio cable Con...
TANDBERG 7000 MXP 16 2.3 Monitor Configuration Power on Switch the system on by connecting the power cable to an electrical distribution socket. After the system has performed a self-test routine, the Menu will be displayed on the monitor.
Installation 17 2.4 System Configuration The system must be configured for each installation. Configuration settings can be made via the system menu. If an external IMUX or non-standard network is being used it may be necessary to configure any associated external equipment. Navigate through the men...
3 General Use Wake up the system When the system is not in use, it is in standby mode and the screens are black. Wake up the system by picking up the remote control. An incoming call or pressing any key on the remote control will also wake up the system. If the system does not respond: Make sure t...
Administrator Settings 21 3.1 The Welcome Screen When the system is switched on, the welcome screen will be displayed. The welcome screen presents the menu and displays your main camera image in the background (display main camera is the default setting). The ISDN/IP numbers and the system name are ...
TANDBERG 7000 MXP 22 3.2 Using the Remote Control The system is controlled with a remote control. Think of the remote control as a mobile phone with number keys and call keys. Use the arrow keys and press OK to navigate through the menus. The system’s most commonly used functions are also accessible...
Administrator Settings 27 3.2.2 Selfview The term “Selfview” means the outgoing image. In a normal call using the main camera, this is the image of you. The Selfview button toggles the images between Far End, Selfview and Dual Video (if any). How to use Selfview: 1. Outside a call, pressing the Self...
Administrator Settings 29 3.2.3 Picture Layout The layout of the screen can either be shown as Picture in Picture (PIP) or Picture outside Picture (POP) when displaying more than one video image. The behavior of the Layout button is dependent on the Picture Layout setting in Screen Settings . 3.2.3....
TANDBERG 7000 MXP 30 3.2.4 Mic Off To mute the microphone during a call, press the Mic off button. An on-screen indicator appears in the upper right corner when the microphone is off. In a call, if audio is detected, the on-screen symbol will start to flash. Pressing the Mic off button one more time...
TANDBERG 7000 MXP 32 3.2.6 Number and Letter keys Pressing a number key when outside a call will bring up the call menu. When in a call, the number keys are used for Camera Presets. Press a number and go to the corresponding Camera Preset (see Camera Presets ). However, when accessing an input field...
Administrator Settings 33 3.2.7 Touch Tones To activate dialing touch tones during a call, press the Touch tones button. Otherwise the number keys will work as configured in the Number Key Mode, see Control Panel – Menu Settings – Number Key Mode. An indicator will let you know that Touch tones are ...
TANDBERG 7000 MXP 34 3.2.8 Presets and Extension Numbers When pressing a number key on the remote control, while in a call, the user can decide what shall happen. The system can be configured to act automatic or manual. While in a call, the user presses a number key to: • add another call • dial ext...
TANDBERG 7000 MXP 40 3.5.1 Place a Call The TANDBERG system can make both Video calls and Telephone calls . A Call Type selector button is placed to the right of the number entry field. The button shows if it is a video call (default) or a telephone call. Press the button to show a drop down list to...
TANDBERG 7000 MXP 42 3.5.2 Add Call (Optional feature) Conference systems with built-in MultiSite can handle up to 6 video calls and 5 telephone calls simultaneously. It is possible to both set up a conference with many participants and also add participants during a conference. Set up a conference ...
Administrator Settings 43 3.5.3 Call Settings The Call Settings specifies the quality of the call. Each call will be set up with the default Call Settings if the settings are not altered. Normally it is not necessary for the user to alter the settings. The Call Settings are defined in Control Panel ...
TANDBERG 7000 MXP 44 3.5.4 SIP Services SIP enables you to use the features Add Call and Transfer even if your system doesn’t have multipoint capabilities. To get the SIP Services available, you have to make a call using SIP as your Net. (See Call Settings) 3.5.4.1 Add Call You can add another call ...
Administrator Settings 45 3.5.5 Streaming Streaming lets you broadcast your meeting to participants on the web. The web participants can listen to the meeting, see snapshots, but not participate themselves. Snapshots of current stream (if MultiSite), selfview, far end and DuoVideo streams are access...
Administrator Settings 47 3.5.6 Dialing In From Outside the Enterprise Dialing in Without Being Registered to a TANDBERG Gatekeeper The feature enhancement enables dialing through a TANDBERG Gatekeeper without being registered to it. This makes it easy to call in from a video system outside the ente...
TANDBERG 7000 MXP 48 3.6 Answer an incoming call How to answer an incoming call: To accept an incoming call, press the OK button or the green Call button on the remote control. How to reject an incoming call: To reject an incoming call, select the Reject icon and press the OK button, or press th...
Administrator Settings 51 3.8.1 Delay Standby for 1 hour Delay Standby for 1 hour postpones the system from entering standby mode for 1 hour. This function is useful when using the monitors for a local presentation to prevent the system from automatically blanking the monitors. It is also possible t...
TANDBERG 7000 MXP 52 3.8.2 Delay Standby for 3 hours Delay Standby for 3 hours postpones the automatic standby mode for 3 hours. This function is useful when using the monitors for a local presentation to prevent the system from automatically blanking the monitors. It is also possible to postpone th...
Administrator Settings 53 3.8.3 Do Not Disturb To prevent the system from accepting any incoming calls, activate the Do Not Disturb function. The caller will hear a busy tone when calling the system. The monitor will be black when Do Not Disturb is active, see figure below. This is useful when using...
TANDBERG 7000 MXP 56 3.9.1 Call Log The Call Log lists Placed Calls, Missed Calls and Received Calls. That allows the user to see which calls that are made in the past. The lists contain a maximum of 30 numbers and the numbers are stored in these lists until the system is restarted. If the contacts ...
Administrator Settings 57 3.9.2 My Contacts My Contacts are the locally stored contacts on the system. This means that it is possible to add new contacts and edit or delete existing contacts. My Contacts can store up to 200 contacts. How to make a call using My Contacts: 1. Find the desired contact ...
Administrator Settings 59 3.9.2.1 Add New Contact The New Contact function is available from My Contacts . Add a new contact to My Contacts by: 1. Select the New Contacts button to open the New Contacts dialog box. 2. Enter Name by using the letter keys on the remote control. Input will automaticall...
TANDBERG 7000 MXP 60 3.9.2.2 New MultiSite Contact (Optional feature*) The New MultiSite Contact function is available from My Contacts . It is possible to pre-define the participants of a conference meeting as a MultiSite Contact. All participants in the MultiSite Contact will then be connected aut...
TANDBERG 7000 MXP 62 3.9.2.3 Edit Contact The Edit Contact function is available from My Contacts . How to edit a contact in the Local Phone Book: 1. Select the contact that is to be edited. 2. Press the left arrow on the remote control, followed by the down arrow until the Edit Contact icon is sele...
Administrator Settings 63 3.9.2.4 Delete Contact The Delete Contact function is available from My Contacts . How to delete a contact: 1. Select the contact that is to be deleted. 2. Press the left arrow on the remote control, followed by the down arrow until the Delete Contact icon is selected. The ...
TANDBERG 7000 MXP 64 3.9.3 Corporate Contacts / Global Contacts When selecting Phone Book the phone book opens showing the Global Contacts* or the Corporate Directory** below the folders Placed Calls, Missed Calls, Received Calls and My Contacts. These contacts cannot be changed locally by the syste...
TANDBERG 7000 MXP 66 3.9.3.2 Search The phone book can contain an unlimited amount of global contacts. Using search makes it easier to find the wanted contact. How to search in the Global Phone Book: 1. Select the Search icon. 2. Enter search text in the dialogue box that appears and press the OK bu...
Administrator Settings 67 3.9.3.3 Copy Contact to My Contacts The Copy Contact to My Contacts function is available from the Placed Calls, Missed Calls, Received Calls and Global Contacts folders, see Phone Book for details. It may be wise to copy contacts that are often used to My Contacts. Note th...
Administrator Settings 69 3.10.1 Move Camera It is possible to move the camera with the remote control or via the menu. Moving the camera directly with the remote control When the menu is hidden, the arrow keys will work on the camera. If the menu is displayed, press the Cancel button on the remote ...
TANDBERG 7000 MXP 70 3.10.2 Far End Control Far End Control allows you to control your conference partner’s camera. An example of when this feature could be especially helpful is if it is not possible to see what a participant at the far end is writing on their white board. Use Far End Control to mo...
Administrator Settings 71 3.10.3 Camera Presets Use camera presets to easily vary between predefined near end camera angles. This is useful when pictures from many different camera angles have to be sent to the far end. E.g. in a meeting there is a white board, a PC and a small meeting table. Use ca...
TANDBERG 7000 MXP 72 3.10.4 TANDBERG Tracker How to save presets for the TANDBERG Tracker: 1. Select which camera preset is to be used on the TANDBERG Tracker. 2. Move the camera to the desired position to store on the tracker. 3. Select Move Camera - Save New Preset in the menu. 4. All camera prese...
Administrator Settings 73 3.10.5 Picture Control Focus, Brightness and White balance are set for auto focus, auto brightness and auto white balance by default. If you need to set focus, brightness and white balance manually, go to Picture Control in the Camera Control menu. Focus Auto Auto focus con...
TANDBERG 7000 MXP 74 3.10.6 Camera Tracking Through Camera Tracking and the use of two or three microphones, the camera can automatically position itself on the current speaker. Before using camera tracking, the camera positions used must be stored at Preset 7 (Mic1), Preset 8 (Mic2) and/or Preset 9...
TANDBERG 7000 MXP 76 3.11.1 Presentation Key The quickest way to show a presentation is to use the presentation key on the remote control. The presentation key is used to start and stop a presentation. The presentation key will display PC (default*). When holding the presentation key for 1 second, t...
Administrator Settings 77 3.11.2 Presentation Menu The Presentation menu offers you all available video sources; Main Camera, PC, Document Camera, VCR, AUX and VNC. All these sources can be used as Main Video Stream or Dual Video Stream (Duo Video / H.239). Not all systems has all video sources avai...
Administrator Settings 79 3.11.4 PC Soft Presenter and VNC (Optional feature) PC SoftPresenter is used to display PC images on your system without using a VGA cable (PC Presenter). The system and your PC must be connected to the same LAN. In addition, VNC (Virtual Network Computing) server software ...
TANDBERG 7000 MXP 80 3.11.5 Dual Stream (DuoVideo TF /H.239) (Optional feature - not available on all systems) With Dual Stream you have the opportunity to show two different live video streams simultaneously, main video and one additional source. This is handy when showing a presentation. You see t...
Administrator Settings 81 3.11.6 Take New Snapshot The system can take a snapshot of your live video. Snapshot is handy when you are in a call with a system that does not support Dual Stream. Use Snapshot to show a snapshot of your presentation and continue the meeting with main camera. How to use s...
TANDBERG 7000 MXP 82 3.11.7 Display Snapshot The system stores the last sent or received Snapshot. The snapshot is deleted automatically after the call. How to display snapshots: 1. To view a stored snapshot, first choose the Snapshot header. 2. Select Display Snapshot in the Presentation menu. 3. P...
Administrator Settings 83 3.12 Conference Services A Multipoint Control Unit (MCU) enables several sites to participate in the same conference. During an MCU conference, the status line will provide information about the conference. Services contain the following features: • Request Floor and Releas...
TANDBERG 7000 MXP 86 3.12.1 Request Floor and Release Floor When requesting floor, your video will be broadcasted in full screen to all other participants in the conference. Request Floor is useful when you want to speak or display something in front of all participants. Release Floor when you are d...
Administrator Settings 87 3.12.2 Conference Layout (Only supported by TANDBERG MultiSite*) With a TANDBERG MultiSite you can choose between the layouts: Auto Split, 4 Split, 5+1 Split and Voice Switched view. Auto Split displays all participants on the screen simultaneously. 4 Split displays the 4 l...
TANDBERG 7000 MXP 88 3.12.3 Terminal Names Choose Terminal Names to see a list of the participants of the MultiSite conference. Press Cancel to go back.
Administrator Settings 89 3.12.4 Chair Control (Not supported by TANDBERG MCU or MultiSite) As chairman, you have access to more MultiSite Services. Select Chair Control to assume the role of chairman of the conference. Select Release Chair to end the role as chairman. A Chair indicator appears when...
Administrator Settings 91 3.12.6 View Site and End View (Not supported by TANDBERG MCU or MultiSite) View Site allows you to view any participant in the conference regardless of who has the floor and chair. Choose End View to go back to normal.
TANDBERG 7000 MXP 92 3.12.7 Disconnect Participant Disconnect Participant allows the chairman to disconnect any participant in the conference. In a multipoint call, this is equivalent to disconnecting a participant from the end call menu.
Administrator Settings 93 3.12.8 Terminate Meeting Terminate Meeting allows the chairman to terminate the conference altogether. In a MultiSite call, this is equivalent to pressing End All Calls from the end call menu.
Administrator Settings 97 4 Control Panel The Control Panel contains the following features: User Guide Diagnostics Audio Demo Restart Settings* Settings: General Call Quality Security Menu Settings Audio Network Presentation Settings Video Restore Default Settings NOTE: ...
TANDBERG 7000 MXP 100 4.2.1 System Information Select System Information to view system numbers, line status, software version, hardware serial number and other useful information. Press arrow key up and down to scroll in the System Information list. System Information contains: System Name My ISDN ...
Administrator Settings 101 4.2.2 Channel Status Comprehensive information about the call progress is available through the Channel Status window. This window indicates the various stages each B-channel goes through whilst establishing a connection. Status - BRI Comments Idle Calling Connected Sync A...
TANDBERG 7000 MXP 104 4.2.4 System Selftest The system performs a check to determine internal hardware integrity. System Selftest is useful when you want to check if your network connection is active.
TANDBERG 7000 MXP 110 4.2.6 IP Address Conflict Check The system will give a warning if there is an IP conflict. The user may initiate this check by selecting IP Address Conflict Check.
Administrator Settings 115 5 System Settings The Control Panel contains all the settings of the system. Making changes to the settings will change the behavior of the system. It is recommended to password protect the access to the settings to prevent occasional users from making crucial changes to t...
TANDBERG 7000 MXP 116 5.1 General Settings When installing the system, go through the General Settings menu to ensure that you have the right settings for your system, see System Configuration. General Settings contain: Language System Name / International Name* Auto Answer Phone Book Settin...
TANDBERG 7000 MXP 118 5.1.2 System Name System Name identifies the system: On the welcome page. During an MCU conference call. When using the Web-interface. When the codec is acting as an SNMP Agent. Towards a DHCP server. H323 ID. Other systems can call in using this name instead of IP-...
TANDBERG 7000 MXP 120 5.1.4 Auto Answer The auto answer setting decides whether an incoming call is put through automatically or manually. On The system will automatically answer all incoming calls. On+Mic Off The system will automatically answer all incoming calls and switch the microphone off when...
Administrator Settings 121 5.1.5 Phone Book Settings Corporate Directory On The Corporate Directory is available in the menu. Off The Corporate Directory is hidden from the menu and is unavailable for users. IP address Enter the IP address of the management system that provides the Phone Book. Path ...
TANDBERG 7000 MXP 122 5.1.6 External Services Settings External Services On When set to On External Services are available. Off When set to Off External Services are unavailable. IP address Enter the IP address of the service provider for External Services. Path Enter the Path to the External Servic...
Administrator Settings 131 5.1.9 Software Options The system requires a valid option key to activate MultiSite and/or Presenter functionality. In order to activate additional bandwidth, you need to enter a bandwidth key. A restart of the system is required after entering a new option and/or bandwidt...
TANDBERG 7000 MXP 132 5.1.10 Date and Time Settings NTP IP This is the NTP time server address from which the system can get updated time information. See IP Services for more details. Auto The NTP IP will be provided by the DHCP server. Manual The NTP IP address is set manually. IP Address The IP A...
TANDBERG 7000 MXP 134 5.2.1 Input Editor Language When the Input Editor Language is set to Chinese, Korean or Japanese the user will be able to enter Chinese / Korean / Japanese characters into an input field like the System Name or Phone Book, using the remote control.
Administrator Settings 135 5.2.2 Menu Timeout in Call The Menu appears on the bottom line of the screen. Set Menu Timeout in Call to On if you want the menu to time out automatically when you are in a call. On The menus will time out automatically after 15 seconds if there is no activity on the remo...
Administrator Settings 137 5.2.4 Menu on PC The Menu on PC setting decides if the menu shall be displayed on the PC (VGA screen) screen or not. For optimal layout of the menu, Menu on TV should be Off if Menu on PC is On and vice versa. On The menu is available on the PC screen. Off The menu is not ...
TANDBERG 7000 MXP 138 5.2.5 Balloon Help It is possible to enable / disable the balloon help window. On Choose On if you want help text windows to appear. Off There will be no help text window.
Administrator Settings 139 5.2.6 Number Key Mode When pressing a number key on the remote control, while in a call, the user can decide what shall happen. The system can be configured to act automatic or manual. While in a call, the user presses a number key to: • add another call • dial extension n...
TANDBERG 7000 MXP 142 5.2.7 Administrator Password It is recommended to put an Administrator Password on the system. The Administrator Password can be maximum 5 digits long. The Administrator Password dialog box will pop up when you choose Settings from the Control Panel. This will prevent occasiona...
Administrator Settings 143 5.2.8 Kiosk Mode Settings Kiosk Mode In Kiosk Mode the system is set to a simplified state where it can be controlled with just the four arrow keys and OK. You will get a simplified on-screen menu with only basic functionality available: make calls (using predefined cont...
Administrator Settings 149 5.3 Presentation Settings Presentation Settings contain: Presentation Start H.239 Startup Video Source Presentation Source Snapshot Source Auto-Display Snapshot PIP Placing Presentation Rate VNC Settings
TANDBERG 7000 MXP 150 5.3.1 Presentation Start If your system has Dual Stream capabilities, you can show two video streams at the same time (see also Dual Stream ). Presentation Start is Auto by default. This means that you will start Dual Stream (a second video stream) automatically when starting a...
TANDBERG 7000 MXP 152 5.3.3 Startup Video Source The Startup Video Source is the video source on display when the system wakes up from standby mode. If you use Main Camera as start up source, the system will start with Main Camera every time the system wakes up from standby, regardless of what the p...
Administrator Settings 153 5.3.4 Presentation Source The Presentation Source is connected to the Presentation button on the remote. Pressing the Presentation button will put the Presentation Source on display. Presentation Source is PC by default*. You can change the Presentation Source to any video...
Administrator Settings 155 5.3.6 Auto-Display Snapshot Select Auto to automatically display a received snapshot. Turn Auto-Display Snapshot Manual if you wish not to have them displayed on the screen when they are sent or received. The snapshots will be sent and received, but not displayed. With Aut...
TANDBERG 7000 MXP 156 5.3.7 PIP Placing PIP Placing lets you decide where the PIP shall appear. You can of course move the PIP with the Layout button on the remote anytime. Top Right PIP is placed in the Top Right corner. Bottom Right PIP is placed in the Bottom Right corner. Bottom Left PIP is plac...
Administrator Settings 157 5.3.8 Presentation Rate When setting up a call with H.323 the bandwidth can be controlled by the user. The Presentation Rate is expressed in percent of the Call Rate and shall reflect the H.323 Presentation Rate settings of the sender. The settings are 25%, 50% and 75% of ...
TANDBERG 7000 MXP 160 5.4.1 Video Algorithm The system will automatically select the best video algorithm based on the video source and the capabilities of the remote system. Use this menu to disable video algorithms in case you have interoperability issues calling other systems. H.264 Bandwidth eff...
Administrator Settings 163 5.4.4 Natural Video Choosing Natural Video will enable 60 fields* per second true interlaced picture for high motion video. The use of Natural Video requires the H.263+ and H.263++ video protocols. Natural video will be disabled in H.323 MultiSite calls and in H.320 Contin...
Administrator Settings 165 5.4.6 Video Quality The different video sources need different Video Quality Settings. Main Camera, VCR, AUX and Split Screen have Motion as default. PC, Document Camera and VNC have Sharpness as default. Motion* Optimized for smooth motion video (CIF/SIF or 288p for low b...
TANDBERG 7000 MXP 168 5.4.7 Default Call Settings Default Call Settings are connected with Call Settings in the call menu. If you leave Call Settings unchanged when making a call, the system will use the default Call Settings in the call. In addition to the Call Settings Call Type, Net, Bandwidth an...
TANDBERG 7000 MXP 182 5.5.6 Alert Tones and Volume Video Call Alert Tone and Telephone Alert Tone To help distinguish between incoming video calls and ordinary telephone calls, it is recommended to use different ringing tones for video calls and telephone calls. Alert Volume You may change the volum...
Administrator Settings 183 5.5.7 Graphical View Graphical View The graphical view is a visual presentation of the audio inputs and audio outputs. • The Inputs + Far End In are listed on the left, showing the name of the input sources. • The outputs + Far End Out are listed on the bottom, showing the...
TANDBERG 7000 MXP 186 5.6.2 MCU Status Line On The MultiSite / MCU / DuoVideo indicators will be displayed and provide information about the conference. Off The MultiSite / MCU / DuoVideo indicators will not be displayed. Auto The MultiSite / MCU / DuoVideo indicators will be displayed for a few sec...
Administrator Settings 187 5.6.3 Floor to Full Screen When "Floor to Full Screen" is enabled, someone who requests floor will be seen by all participants as full screen. When "Floor to Full Screen" is "Off", someone who request floor in a MultiSite conference using the 5+1 la...
TANDBERG 7000 MXP 188 5.6.4 Web Snapshots The system is able to generate JPEG snapshots and provide them when requested (as ‘http get’ or via ftp). See Appendix 6 for descriptions of the possible snapshot files. On Snapshots generation is enabled. Off Snapshots generation is disabled. Note that web ...
Administrator Settings 189 5.6.5 MultiSite Picture Mode MultiSite* Picture Mode determines the default layout of a MultiSite call. Available layouts are: Auto Split, 4 Split, 5+1 Split, and Voice Switched. You can change the layout during a call using the layout option in MultiSite Services. Auto Sp...
TANDBERG 7000 MXP 194 5.7.2 Encryption Mode Auto The system will try to use the most secure encryption - AES, dependent on the capabilities of the other sites. For sites that do not support AES encryption, DES encryption will be tried. AES The system will try to use AES with 128 bits encryption when...
TANDBERG 7000 MXP 196 5.7.4 Camera Standby Mode There is a setting to the Security menu called Camera Standby mode On (default)/Off. When Camera Standby mode is On, the camera turns away when standby is activated. When the system is activated the camera turns back to normal position. On The camera w...
Administrator Settings 199 5.8.1.1 ISDN-BRI Settings To make sure your system will work properly using ISDN-BRI, make the following settings: 1. Set ISDN switch type 2. Enter ISDN line numbers (+ SPIDs if required) 3. Disable unused lines Some software versions do not support 6 ISDN lines, therefore...
TANDBERG 7000 MXP 200 Advanced ISDN Settings Sub address Using a sub address enables you to connect up to eight ISDN terminals to the same ISDN telephone number and line. The terminals are addressed by using different sub addresses. To call a terminal with a sub address, separate the ISDN telephone ...
Administrator Settings 201 5.8.1.2 ISDN-PRI Settings To make sure your system will work properly using ISDN-PRI, configure the following settings: 1. Set PRI switch type 2. Enter PRI line number Note that the T1 format is predefined to ESF and the line code is B8ZS. This is not configurable. Number ...
TANDBERG 7000 MXP 202 Example: Max Channels may be used for PRIs that are provisioned for a lower number of channels. High Channel, Low Channel and Search may be used for PRIs provisioned with specific requirements for B-channel usage. In the example above, the system will start searching for availa...
Administrator Settings 203 Advanced ISDN-PRI Settings NSF is a non standard facility. Your network provider may require a service selection in your ISDN configuration. Enter the Service code here. Valid NSF service codes are from 1 to 31. Enter 0 to disable NSF service codes. Example: AT&T offer...
Administrator Settings 211 DNS Settings DNS Server 1-5 DNS Server defines the network addresses for DNS servers. Up to 5 addresses may be specified. If the network addresses are unknown, please contact your administrator or Internet Service Provider. DNS Domain Name DNS Domain Name is the default do...
Administrator Settings 213 Gatekeeper Settings Gatekeeper Discovery Auto The system will automatically try to register to any available gatekeeper. If a gatekeeper responds to the request sent from the codec within 30 seconds this specific gatekeeper will be used. This requires auto discovery on the...
Administrator Settings 215 CallManager Settings CallManager IP This is the CallManager IP-address that is used if you specify H.323 Call Setup: CallManager.
TANDBERG 7000 MXP 216 Advanced H.323 Settings The Advanced H.323 Settings only have an effect if they are supported by your IP infrastructure. NAT NAT, Network Address Translation, is used when a PC and a videoconferencing system are connected to a router with NAT support. NAT support in the videoco...
TANDBERG 7000 MXP 218 5.8.2.3 SIP Settings Mode On Setting the SIP mode to on will enable the system for incoming and outgoing SIP calls. Off Setting the SIP mode to off will disable incoming and outgoing SIP calls from the system. Display Name The Display name part of the SIP Address (URI) is usual...
Administrator Settings 219 Server Address The Server Address is the manually configured address for the outbound proxy and registrar. It is possible to use a fully qualified domain name, or an IP address. The default port is 5060 for TCP and UDP, but another one can be provided. Server Address: <...
TANDBERG 7000 MXP 220 RFC 2032 RTP Payload Format for H.261 Video Streams Draft-ietf-avt-rfc2032-bis-06.txt - Draft for advanced video signaling including resolution and mpi. RFC 2190 RTP Payload Format for H.263 Video Streams RFC 2429 RTP Payload Format for the 1998 Version of ITU-T Rec. H....
TANDBERG 7000 MXP 226 5.8.3 Network Profiles This menu consists of 7 network profiles; a prefix and a suffix can be added for each profile. If you add a prefix/suffix to a profile, this prefix/suffix will automatically be added in front/back of the number being dialed. Example: 0 is added as a Call ...
Administrator Settings 227 5.8.4 Data Port The system provides up to two standard RS232 serial ports to allow a computer to be connected for data transfer and control purposes. Note that when connecting to a PC the connecting cable must be a straight through RS232 cable. Baud Rate, Parity, Data bits...
TANDBERG 7000 MXP 228 5.8.5 Restore Default Settings Restore Default Settings will restore all system settings. Note that this will not affect your Call Directory information, Network Type, Line Setup numbers or your SPID numbers.
6 Peripheral Equipment Using the optional peripheral devices outlined in this chapter and the many others available, you will be able to build your own applications for use with the system, thereby better integrating the system into your business environment. This chapter will explain how to connect...
TANDBERG 7000 MXP 240 6.1.4 Data port The data port(s) are implemented as Data Communications Equipment (DCE). The connector used are female 9-pin D-subs. NOTE! Data port 2 is used by both Wave II Camera and Precision HD Camera and has different pin-out scheme for the different use. The TANDBERG mai...
Peripheral Equipment 243 6.4 Additional Cameras Extra fixed Cameras You can connect extra fixed cameras to your system, for example, a whiteboard camera. Connect the video output of the additional camera to one of the available Video inputs on the system. Multiple controllable Cameras Attaching mult...
TANDBERG 7000 MXP 244 6.5 Additional Microphones If your environment is such that you require more than one microphone for your room, e.g. you have a whiteboard at a distance from your table microphone, it is possible to connect additional microphones to your system. See Appendix 4 for more informat...
Peripheral Equipment 249 TANDBERG 3000 MXP Profile: The TANDBERG Mini-DNAM*: The Mini-DNAM audio system is built on two specially designed and separate modules; the Mini-DNAM amplifier and the Mini-DNAM loudspeaker cabinet. The Mini-DNAM loudspeaker cabinet is stereo-configured and based on two vers...
TANDBERG 7000 MXP 250 6.7 Stereo Speaker Kit Note that the following applies only for systems with a stereo S/PDIF output. The Stereo Speaker Kit provides an pair of floor-standing loudspeakers in addition to the built-in DNAM . Using these speakers will enable stereo functionality in your system an...
TANDBERG 7000 MXP 254 6.10 XGA Monitors and Projectors (Optional) Some TANDBERG systems can be delivered with optional single or dual TV/XGA monitors. It can also be connected to any DVI/VGA/PAL or NTSC display. Note that this requires a system with minimum one DVI-I output.
Peripheral Equipment 257 6.13 Extended Display Identification Data (EDID) Extended Display Identification Data (EDID) is a VESA standard data format that will allow the system to communicate its capabilities, including vendor information like the supported VGA-formats and frequency range limits to a...
7 Appendices Appendices: Appendix 1: Technical Specification Appendix 2: Bandwidth Information Appendix 3: Environmental considerations Appendix 4: Guidelines for setting up rooms for video meetings Appendix 5: Security Appendix 6: Using the file system Appendix 7: Web Interface Appe...
TANDBERG 7000 MXP 260 Appendix 1: Technical Specifications Technical Specification UNIT DELIVERED COMPLETE WITH: 2 x 30" widescreen LCD monitors, wireless remote control, Tracker, W.A.V.E. II camera, microphone, Audio ModuleTM, integrated cabling and stand MONITORS Dual 30" LCD monitors 16:9...
Glossary 263 Appendix 2: Bandwidth Information for TANDBERG Endpoints Bandwidth information for TANDBERG endpoints Model 8000MXP, 7000MXP 6000MXP, Maestro Bandwidth Point to point ISDN / IP Standard: 768 / 3072 Option: 1920 / 4096 Standard: 768 / 3072 Option: 1920 / 4096 MultiSite Total: 3072kbps 4x...
Glossary 265 Appendix 3: Environmental Considerations Environmental considerations This section explains how to carry out basic adjustments and simple tests to ensure that you send and receive the best possible image and audio quality when using your system. Iris control and lighting By default the ...
TANDBERG 7000 MXP 266 Appendix 4: Guidelines for Setting up Rooms for Video Meetings Guidelines for setting up rooms for video meetings The following are a set of guidelines to consider when either building a video meeting room, or using an existing room for video meetings. Lighting: Low Contrast ...
TANDBERG 7000 MXP 268 Appendix 5: Security Security The system has several features both to protect from unauthorized use and system access: Access Code: When Access Code is enabled, the user will be asked to enter an access code before he/she is able to make a call. The system will verify if the en...
Glossary 271 Appendix 6: Using the File System Using the file system It is possible to access a file system within the TANDBERG system by using ftp: DOS-window: ftp <IP-address of system>, or Web-browser: ftp:// <IP-address of system> Description of the different files: all.prm all setti...
TANDBERG 7000 MXP 272 Appendix 7: Web Interface Web Interface It is possible to access and maintain the system remotely via a local area network (LAN) using a standard Web-browser. Connect your system to a LAN with a Network cable. How to configure your system for web interface: 1. Open Control Pane...
Glossary 273 Appendix 8: Connecting the System to PRI/T1 (Not available on all TANDBERG systems) Connecting the system to PRI/T1 Using CSU adapter Connecting the system to the ISDN network via the E1/T1-interface using an Adtran T1 ESF CSU ACE or equivalent CSU, will allow up to 1.54 Mbps connection...
TANDBERG 7000 MXP 274 Appendix 9: Connecting the System to the Switched 56 Network Connecting the system to the Switched 56 network Using Telesync TS-256 SW56/ISDN adapter Connecting the system to the SW56 network using a Telesync Adapter is described below. There are different Telesync Adapters for...
Glossary 277 Appendix 11: TANDBERG Cameras TANDBERG Precision HD Camera (Available to TANDBERG 8000 MXP, 6000 MXP Profile, 3000 MXP Profile*, Maestro MXP and Edge 75/85/95 MXP) Pin-outs and Connectors
Glossary 287 Appendix 13: Cisco CallManager Registration Cisco CallManager registration Configuring an H.323 client on the CallManager 4.0 The registration of a H.323 client in CallManager is supported on the CallManager (CCM) 4.0 software and forward. 1. To configure the CallManager with an H.323 c...
TANDBERG 7000 MXP 288 Appendix 14: Diagnostics Tools for IP Diagnostic Tools for IP To use these tools, will require using a PC and setting up a telnet session towards the system. Q.931 To show Q.931 trace during a call you need to issue the command ‘syslog on’.One can get traces for RAS, Q.931 and ...
TANDBERG 7000 MXP 290 Appendix 15: System Upgrade System Upgrade Before starting the software upgrade of the TANDBERG MXP system, please make sure to have the new software file, (for instance s050000F30.pkg) and the Release Key for this software available. Your TANDBERG Partner will provide this for...
TANDBERG 7000 MXP 296 Appendix 16: Declaration of Conformity EC DECLARATION OF CONFORMITY MANUFACTURER: TANDBERG Telecom AS PRODUCT NAME: TANDBERG 7000MXP TYPE NUMBER: TTC60-05 DESCRIPTION: Video Conferencing Equipment This product complies with Commission Directives: • LVD 73/23/EEC • EMC 89/336/EE...
TANDBERG 7000 MXP 298 Appendix 18: Protocols Supported PROTOCOLS SUPPORTED TCP/IP - Transmission Control Protocol/Internet Protocol A set of networking protocols that provides connectivity over LAN/WAN to any network computer. HTTP - Hypertext Transfer Protocol A protocol used to transfer informatio...
TANDBERG 7000 MXP 300 Appendix 19: Cable Specifications TANDBERG MXP and Classic Endpoints that support External Network External Network Pinout With respect to signals on the NET port: • For balanced signals a “0”=low voltage is defined as terminal A positive with respect to terminal B. • For unbal...
TANDBERG 7000 MXP 308 8 Glossary # 199 AV1: External input for the TANDBERG/LOEWE monitor. 2nd monitor: The second monitor of your videoconferencing system. The second monitor is normally placed on the right side of the first monitor. 4CIF: 4 times CIF, 704x576 pixels 4SIF: 4 times SIF, 704x480 pixe...
Index 317 9 Index A Access Code....................................100, 123 Additional microphone .............................244 Administrator Password...........................139 Alert Speaker ...........................................182 Alert Tones and Volume ..........................182 Al...
TANDBERG Manuals
-
TANDBERG 7000
Manual
-
TANDBERG EX90
Manual
-
TANDBERG E5740
Manual
-
TANDBERG D11624
Manual
-
TANDBERG MXP
Manual
-
TANDBERG Intern MXP
Manual
-
TANDBERG D13922.06
Manual
-
TANDBERG 2000MXP
Manual
-
TANDBERG 1500MXP
Manual
-
TANDBERG 880 MXP
Manual
-
TANDBERG MSE 8510
Manual
-
TANDBERG D14306.01
Manual
-
TANDBERG Utility
Manual
-
TANDBERG 6000 MXP
Manual
-
TANDBERG D1440902
Manual
-
TANDBERG D13751.01
Manual
-
TANDBERG D12809
Manual
-
TANDBERG D1392602
Manual
-
TANDBERG MPS 200
Manual
-
TANDBERG TC2.1
Manual