TANDBERG 700 MXP - Manuals
TANDBERG 700 MXP – Manual in PDF format online.
Manuals:
Manual TANDBERG 700 MXP
Summary
User Manual iii Trademarks and Copyright All rights reserved. This document contains information that is proprietary to TANDBERG. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, electronically, mechanically, by photocopying, ...
TANDBERG 7000 MXP vi Environmental Issues TANDBERG visual communication products significantly reduce the need for travel and thereby help reduce various types of pollution. TANDBERG recommends the use of low energy peripherals, such as EnergyStar™ monitors. Thank you for buying a TANDBERG product. ...
User Manual vii Operator Safety Summary For your protection, please read these safety instructions completely before operating the equipment and keep this manual for future reference. The information in this summary is intended for operators. Carefully observe all warnings, precautions and instructi...
User Manual ix Contact us If you have any questions, comments or suggestions, please see the Online Support section at www.tandberg.net . It is also possible to send a fax or mail to the attention of: Product and Sales Support TANDBERG P.O. Box 92 1325 Lysaker Norway Tel: +47 67 125 125 Fax: +47 67 ...
TANDBERG 7000 MXP x Table of Contents 1 Introduction ............................................................................................................................... 1 1.1 At a Glance ........................................................................................................
1 Introduction The TANDBERG 7000 MXP provides high-end performance features, large monitors and precision audio. This creates a collaborative meeting environment for medium to large-sized meeting rooms. Audio Quality High-performance audio provides a richer, more complete visual communication experi...
2 Installation Precautions: Never install communication wiring during a lightning storm. Never install jacks for communication cables in wet locations unless the jack is specifically designed for wet locations. Never touch uninstalled communication wires or terminals unless the telephone line ...
Installation 11 2.1 Unpacking and Mounting 1 Unpacking The TANDBERG 7000 MXP is delivered in one transport case with all components inside as shown in figure 1: Figure 1 Foot Column Monitor Frame with built-in LCD monitors Monitor Rear Cover W.A.V.E. II Camera Accessories box which will ...
TANDBERG 7000 MXP 14 2.2 Connecting Cables 1. Power cable Connect the system power cable to the correct country variant of the power cable. Connect this cable to an electrical distribution socket. 2. Microphone cable Connect the microphone cables to the microphones. 3. DNAM Audio Module - audio cabl...
Installation 15 2.3 Monitor Configuration Power on Switch the system on by connecting the power cable to an electrical distribution socket. After the system has performed a self-test routine, the main menu will be displayed on the monitor.
TANDBERG 7000 MXP 16 2.4 System Configuration The system must be configured for each installation. Configuration settings can be made via the system menu. If an external IMUX or non-standard network is being used it may be necessary to configure any associated external equipment. Navigate through th...
3 General Use Wake up the system When the system is not in use, it is in standby mode and the screens are black. Wake up the system by picking up the remote control. An incoming call or pressing any key on the remote control will also wake up the system. If the system does not respond: Make sure t...
TANDBERG 7000 MXP 20 3.1 The Welcome Screen When the system is switched on, the welcome screen will be displayed. The welcome screen presents the menu and displays your main camera image in the background (display main camera is the default setting). The ISDN/IP numbers and the system name are displ...
General Use 21 3.2 Using the Remote Control The system is controlled with a remote control. Think of the remote control as a mobile phone with number keys and call keys. Use the arrow keys and press OK to navigate through the menus. The system’s most commonly used functions are also accessible direc...
TANDBERG 7000 MXP 26 3.2.2 Selfview The term “Selfview” means the outgoing image. In a normal call using the main camera, this is the image of yourself. The Selfview button toggles the images between Far End, Selfview and Dual Video (if any). How to use Selfview: 1. Outside a call, pressing the Self...
TANDBERG 7000 MXP 28 3.2.3 Layout The layout of the screen can either be shown as Picture in Picture (PIP) or Picture outside Picture (POP) when displaying more than one video image. The behavior of the Layout button is dependent on the Picture Layout setting in Screen Settings . 3.2.3.1 Picture in ...
General Use 29 3.2.4 Mic Off To mute the microphone during a call, press the Mic off button. An on-screen indicator appears in the upper right corner when the microphone is off. In a call, if audio is detected, the on-screen symbol will start to flash. Pressing the Mic off button one more time will ...
General Use 31 3.2.6 Number and Letter keys Pressing a number key when outside a call will bring up the call menu. When in a call, the number keys are used for Camera Presets. Press a number and go to the corresponding Camera Preset (see Camera Presets ). However, when accessing an input field where...
TANDBERG 7000 MXP 32 3.2.7 Touch Tones To activate dialing touch tones during a call, press the Touch tones button. Otherwise the number keys will activate the corresponding camera presets. An indicator will let you know that Touch tones are enabled. Finish with OK to exit Touch tone mode.
TANDBERG 7000 MXP 38 3.5.1 Place Video Call In the Make a Call menu enter the Dial Number either: 1. Manually, or 2. Select the book symbol in order to display the Phone Book and select a conference participant. When dialing manually, toggle between ABC/abc by pressing the # button on the remote con...
General Use 39 3.5.2 Place Telephone Call In the Make a Call menu enter the Dial Number either: 1. Manually, or 2. Select the book symbol in order to display the Phone Book and select a conference participant, see Phone Book for details. When entering a Dial Number manually, toggle between abc/123 b...
TANDBERG 7000 MXP 40 3.5.3 Add Call (Optional feature) Conference systems with built-in MultiSite can handle up to 6 video calls and 5 telephone calls simultaneously. It is possible to both set up a conference with many participants and also add participants during a conference. Set up a conference ...
TANDBERG 7000 MXP 42 3.5.4 Call Settings The Call Settings specifies the quality of the call. Each call will be set up with the Default Call Settings if the settings are not altered. In this case the field is labeled Default Call Settings. If the settings for some reason are altered for the current ...
General Use 43 3.5.5 Streaming Streaming lets you broadcast your meeting to participants on the web. The web participants can listen to the meeting, see snapshots, but not participate themselves. Snapshots of current stream (if MultiSite), selfview, far end and DuoVideo streams are accessible via ht...
General Use 45 3.6 Answer an incoming call How to answer an incoming call: To accept an incoming call, press the OK button or the green Call button on the remote control. How to reject an incoming call: To reject an incoming call, select the Reject icon and press the OK button, or press the End ...
TANDBERG 7000 MXP 48 3.8.1 Delay Standby for 1 hour Delay Standby for 1 hour postpones the system from entering standby mode for 1 hour. This function is useful when using the monitors for a local presentation to prevent the system from automatically blanking the monitors. It is also possible to pos...
General Use 49 3.8.2 Delay Standby for 3 hours Delay Standby for 3 hours postpones the automatic standby mode for 3 hours. This function is useful when using the monitors for a local presentation to prevent the system from automatically blanking the monitors. It is also possible to postpone the syst...
TANDBERG 7000 MXP 50 3.8.3 Do Not Disturb To prevent the system from accepting any incoming calls, activete the Do Not Disturb function. The caller will hear a busy tone when calling the system. The monitor will be black when Do Not Disturb is active, see figure below. This is useful when using the ...
TANDBERG 7000 MXP 52 3.9.1 Call Log The Call Log lists Placed Calls, Missed Calls and Received Calls. That allows the user to see which calls that are made in the past. The lists contain a maximum of 30 numbers and the numbers are stored in these lists until the system is restarted. If the contacts ...
General Use 53 3.9.2 My Contacts My Contacts are the locally stored contacts on the system. This means that it is possible to add new contacts and edit or delete existing contacts. My Contacts can store up to 200 contacts. How to make a call using My Contacts: 1. Find the desired contact using the a...
General Use 55 3.9.2.1 Add New Contact The New Contact function is available from My Contacts . Add a new contact to My Contacts by: 1. Select the New Contacts button to open the New Contacts dialog box. 2. Enter Name by using the letter keys on the remote control. Input will automatically be interp...
TANDBERG 7000 MXP 56 3.9.2.2 New MultiSite Contact (Optional feature*) The New MultiSite Contact function is available from My Contacts . It is possible to pre-define the participants of a conference meeting as a MultiSite Contact. All participants in the MultiSite Contact will then be connected aut...
TANDBERG 7000 MXP 58 3.9.2.3 Edit Contact The Edit Contact function is available from My Contacts . How to edit a contact in the Local Phone Book: 1. Select the contact that is to be edited. 2. Press the left arrow on the remote control, followed by the down arrow until the Edit Contact icon is sele...
General Use 59 3.9.2.4 Delete Contact The Delete Contact function is available from My Contacts . How to delete a contact: 1. Select the contact that is to be deleted. 2. Press the left arrow on the remote control, followed by the down arrow until the Delete Contact icon is selected. The Delete Cont...
TANDBERG 7000 MXP 62 3.9.3.2 Search The phone book can contain an unlimited amount of global contacts. Using search makes it easier to find the wanted contact. How to search in the Global Phone Book: 1. Select the Search icon. 2. Enter search text in the dialogue box that appears and press the OK bu...
General Use 63 3.9.3.3 Copy Contact to My Contacts The Copy Contact to My Contacts function is available from the Placed Calls, Missed Calls, Received Calls and Global Contacts folders, see Phone Book for details. It may be wise to copy contacts that are often used to My Contacts. Note that the loca...
General Use 65 3.10.1 Move Camera It is possible to move the camera with the remote control or via the menu. Moving the camera directly with the remote control When the menu is hidden, the arrow keys will work on the camera. If the menu is displayed, press the Cancel button on the remote control to ...
TANDBERG 7000 MXP 66 3.10.2 Far End Control Far End Control allows you to control your conference partner’s camera. An example of when this feature could be especially helpful is if it is not possible to see what a participant at the far end is writing on their white board. Use Far End Control to mo...
General Use 67 3.10.3 Camera Presets Use camera presets to easily vary between predefined near end camera angles. This is useful when pictures from many different camera angles have to be sent to the far end. E.g. in a meeting there is a white board, a PC and a small meeting table. Use camera preset...
TANDBERG 7000 MXP 68 3.10.4 TANDBERG Tracker How to save presets for the TANDBERG Tracker: 1. Select which camera preset is to be used on the TANDBERG Tracker. 2. Move the camera to the desired position to store on the tracker. 3. Select Move Camera - Save New Preset in the menu. 4. All camera prese...
General Use 69 3.10.5 Picture Control Focus, Brightness and White balance are set for auto focus, auto brightness and auto white balance by default. If you need to set focus, brightness and white balance manually, go to Picture Control in the Camera Control menu. Focus Auto Auto focus continuously u...
TANDBERG 7000 MXP 70 3.10.6 Camera Tracking Through Camera Tracking and the use of two or three microphones, the camera can automatically position itself on the current speaker. Before using camera tracking, the camera positions used must be stored at Preset 7 (Mic1), Preset 8 (Mic2) and/or Preset 9...
TANDBERG 7000 MXP 72 3.11.1 Presentation Key The quickest way to show a presentation is to use the presentation key on the remote control. The presentation key is used to start and stop a presentation. The presentation key will display PC (default*). When holding the presentation key for 1 second, t...
General Use 73 3.11.2 Presentation Menu The Presentation menu offers you all available video sources; Main Camera, PC, Document Camera, VCR, AUX and VNC. All these sources can be used as Main Video Stream or Dual Video Stream (Duo Video / H.239). Not all systems has all video sources available, see ...
General Use 75 3.11.4 PC Soft Presenter and VNC (Optional feature) PC SoftPresenter is used to display PC images on your system without using a VGA cable (PC Presenter). The system and your PC must be connected to the same LAN. In addition, VNC (Virtual Network Computing) server software must be ins...
General Use 77 3.11.6 Take New Snapshot The system can take a snapshot of your live video. Snapshot is handy when you are in a call with a system that does not support Dual Stream. Use Snapshot to show a snapshot of your presentation and continue the meeting with main camera. How to use snapshot: Yo...
TANDBERG 7000 MXP 78 3.11.7 Display Snapshot The system stores the last sent or received Snapshot. The snapshot is deleted automatically after the call. How to display snapshots: 1. To view a stored snapshot, first choose the Snapshot header. 2. Select Display Snapshot in the Presentation menu. 3. P...
General Use 79 3.12 Conference Services A Multipoint Control Unit (MCU) enables several sites to participate in the same conference. During an MCU conference, the status line will provide information about the conference. You can make a multipoint conference in different ways. The Conference Service...
TANDBERG 7000 MXP 82 3.12.1 Request Floor and Release Floor When requesting floor, your video will be broadcasted in full screen to all other participants in the conference. Request Floor is useful when you want to speak or display something in front of all participants. Release Floor when you are d...
General Use 83 3.12.2 Conference Layout (Only supported by TANDBERG MultiSite*) With a TANDBERG MultiSite you can choose between the layouts: Auto Split, 4 Split, 5+1 Split and Voice Switched view. Auto Split displays all participants on the screen simultaneously. 4 Split displays the 4 last speakin...
TANDBERG 7000 MXP 84 3.12.3 Terminal Names Choose Terminal Names to see a list of the participants of the MultiSite conference. Press Cancel to go back.
General Use 85 3.12.4 Chair Control (Not supported by TANDBERG MCU or MultiSite) As chairman, you have access to more MultiSite Services. Select Chair Control to assume the role of chairman of the conference. Select Release Chair to end the role as chairman. A Chair indicator appears when you have C...
General Use 87 3.12.6 View Site and End View (Not supported by TANDBERG MCU or MultiSite) View Site allows you to view any participant in the conference regardless of who has the floor and chair. Choose End View to go back to normal.
TANDBERG 7000 MXP 88 3.12.7 Disconnect Participant Disconnect Participant allows the chairman to disconnect any participant in the conference. In a multipoint call, this is equivalent to disconnecting a participant from the end call menu.
General Use 89 3.12.8 Terminate Meeting Terminate Meeting allows the chairman to terminate the conference altogether. In a MultiSite call, this is equivalent to pressing End All Calls from the end call menu.
TANDBERG 7000 MXP 94 3.13.2 System Information Select System Information to view system numbers, line status, software version, hardware serial number and other useful information. Press arrow key up and down to scroll in the System Information list. System Information contains: System Name My ISDN ...
General Use 95 3.13.3 Channel Status Comprehensive information about the call progress is available through the Channel Status window. This window indicates the various stages each B-channel goes through whilst establishing a connection. Status - BRI Comments Idle Calling Connected Sync Active Relea...
TANDBERG 7000 MXP 98 3.13.5 System Selftest The system performs a check to determine internal hardware integrity. System Selftest is useful when you want to check if your network connection is active.
General Use 99 3.13.6 View Administrator Settings This window displays all the system settings. Use the arrow key on the remote control to scroll through the list. View Administrator Settings may contain*: General Settings System Name Language Dual Monitor Auto answer Max Call Length Access Code Inc...
General Use 103 3.13.7 IP Address Conflict Check The system will give a warning if there is an IP conflict. The user may initiate this check by selecting IP Address Conflict Check.
TANDBERG 7000 MXP 106 3.13.9 Text Chat While in an ISDN or IP call to another system supporting Text Chat (T.140), select Text Chat from the Control Panel. Enter text in the displayed window. How to use Text Chat: 1. Choose Text Chat from the Control Panel to open the Text Chat window. 2. Enter text...
4 Administrator Settings Administrator Settings contain all the settings of the system. Making changes to Administrator Settings will change the behavior of the system. It is recommended to password protect the access to Administrator Settings to prevent occasional users from making crucial changes ...
TANDBERG 7000 MXP 112 4.1 General Settings When installing the system, go through the General Settings menu to ensure that you have the right settings for your system, see System Configuration. General Settings contain: Language System Name / International Name* Autoanswer Phone Book Setting...
TANDBERG 7000 MXP 114 4.1.2 System Name System Name identifies the system: On the welcome page. During an MCU conference call. When using the Web-interface. When the codec is acting as an SNMP Agent. Towards a DHCP server. H323 ID. Other systems can call in using this name instead of IP-...
TANDBERG 7000 MXP 116 4.1.4 Auto Answer The auto answer setting decides whether an incoming call is put through automatically or manually. On The system will automatically answer all incoming calls. On+Mic Off The system will automatically answer all incoming calls and switch the microphone off when...
Administrator Settings 117 4.1.5 Phone Book Settings Corporate Directory On The Corporate Directory is available in the menu. Off The Corporate Directory is hidden from the menu and is unavailable for users. IP address Enter the IP address of the management system that provides the Phone Book. Path ...
TANDBERG 7000 MXP 118 4.1.6 External Services Settings External Services On When set to On External Services are available. Off When set to Off External Services are unavailable. IP address Enter the IP address of the service provider for External Services. Path Enter the Path to the External Servic...
Administrator Settings 127 4.1.9 Software Options The system requires a valid option key to activate MultiSite and/or Presenter functionality. In order to activate additional bandwidth, you need to enter a bandwidth key. A restart of the system is required after entering a new option and/or bandwidt...
TANDBERG 7000 MXP 128 4.1.10 Date and Time Settings NTP IP This is the NTP time server address from which the system can get updated time information. See IP Services for more details. Auto The NTP IP address is set automatically. Manual The NTP IP address is set manually. IP Address The IP Address ...
TANDBERG 7000 MXP 130 4.2.1 Input Editor Language When the Input Editor Language is set to Chinese, Korean or Japanese the user will be able to enter Chinese / Korean / Japanese characters into an input field like the System Name or Phone Book, using the remote control.
Administrator Settings 131 4.2.2 Menu Timeout In Call The Main menu appears on the bottom line of the screen. Set Menu Timeout In Call to On if you want the menu to time out automatically when you are in a call. On The menu will time out automatically after 15 seconds if there is no activity on the ...
Administrator Settings 133 4.2.4 Menu on PC The Menu on PC setting decides if the menu shall be displayed on the PC (VGA screen) screen or not. For optimal layout of the menu, Menu on TV should be Off if Menu on PC is On and vice versa. On The menu is available on the PC screen. Off The menu is not ...
TANDBERG 7000 MXP 134 4.2.5 Balloon Help It is possible to enable / disable the balloon help window. On Choose On if you want help text windows to appear. Off There will be no help text window.
Administrator Settings 135 4.2.6 Administrator Password It is recommended to put an Administrator Password on the system. The Administrator Password can be maximum 5 digits long. The Administrator Password dialog box will pop up when you choose Administrator Settings from the Control Panel. This wil...
TANDBERG 7000 MXP 136 4.2.7 Kiosk Mode Settings Kiosk Mode In Kiosk Mode the system is set to a simplified state where it can be controlled with just the four arrow keys and OK. You will get a simplified on-screen menu with only basic functionality available: make calls (using predefined contacts ...
TANDBERG 7000 MXP 142 4.3 Presentation Settings Presentation Settings contain: Presentation Start H.239 Startup Video Source Presentation Source Snapshot Source Auto-Display Snapshot PIP Appearance PIP Placing VNC Settings
Administrator Settings 143 4.3.1 Presentation Start If your system has Dual Stream capabilities, you can show two video streams at the same time (see also Dual Stream ). Presentation Start is Auto by default. This means that you will start Dual Stream (a second video stream) automatically when start...
Administrator Settings 145 4.3.3 Startup Video Source The Startup Video Source is the video source on display when the system wakes up from standby mode. If you use Main Camera as start up source, the system will start with Main Camera every time the system wakes up from standby, regardless of what ...
TANDBERG 7000 MXP 146 4.3.4 Presentation Source The Presentation Source is connected to the Presentation button on the remote. Pressing the Presentation button will put the Presentation Source on display. Presentation Source is PC by default*. You can change the Presentation Source to any video sour...
TANDBERG 7000 MXP 148 4.3.6 Auto-Display Snapshot Select Auto to automatically display a received snapshot. Turn Auto-Display Snapshot Manual if you wish not to have them displayed on the screen when they are sent or received. The snapshots will be sent and received, but not displayed. With Auto-Dis...
Administrator Settings 149 4.3.7 PIP Appearance A Picture in Picture (PIP) is a smaller picture placed in one of the corners of the screen. The PIP enables you to see an extra picture in your video conference. Auto PIP Auto means that Picture In Picture will appear automatically when it is suitable....
TANDBERG 7000 MXP 150 4.3.8 PIP Placing PIP Placing lets you decide where the PIP shall appear. You can of course move the PIP with the Layout button on the remote anytime. Top Right PIP is placed in the Top Right corner. Bottom Right PIP is placed in the Bottom Right corner. Bottom Left PIP is plac...
Administrator Settings 153 4.4.1 Video Algorithm The system will automatically select the best video algorithm based on the video source and the capabilities of the remote system. Use this menu to disable video algorithms in case you have interoperability issues calling other systems. H.264 Bandwidt...
TANDBERG 7000 MXP 156 4.4.4 Natural Video Choosing Natural Video will enable 60 fields* per second true interlaced picture for high motion video. The use of Natural Video requires the H.263+ and H.263++ video protocols. Natural video will be disabled in H.323 MultiSite calls and in H.320 Continuous ...
TANDBERG 7000 MXP 158 4.4.6 Video Quality The different video sources need different Video Quality Settings. Main Camera, VCR, AUX and Split Screen have Motion as default. PC, Document Camera and VNC have Sharpness as default. Motion* Optimized for smooth motion video (CIF/SIF or 288p for low bandwi...
Administrator Settings 175 4.5.6 Alert Tones and Volume Video Call Alert Tone and Telephone Alert Tone To help distinguish between incoming video calls and ordinary telephone calls, it is recommended to use different ringing tones for video calls and telephone calls. Alert Volume You may change the ...
TANDBERG 7000 MXP 178 4.6.2 MCU Status Line On The MultiSite / MCU / DuoVideo indicators will be displayed and provide information about the conference. Off The MultiSite / MCU / DuoVideo indicators will not be displayed. Auto The MultiSite / MCU / DuoVideo indicators will be displayed for a few sec...
Administrator Settings 179 4.6.3 Floor to Full Screen When "Floor to Full Screen" is enabled, someone who requests floor will be seen by all participants as full screen. When "Floor to Full Screen" is "Off", someone who request floor in a MultiSite conference using the 5+1 la...
TANDBERG 7000 MXP 180 4.6.4 Web Snapshots The system is able to generate JPEG snapshots and provide them when requested (as ‘http get’ or via ftp). See Appendix 6 for descriptions of the possible snapshot files. On Snapshots generation is enabled. Off Snapshots generation is disabled. Note that web ...
Administrator Settings 181 4.6.5 MultiSite Picture Mode MultiSite* Picture Mode determines the default layout of a MultiSite call. Available layouts are: Auto Split, 4 Split, 5+1 Split, and Voice Switched. You can change the layout during a call using the layout option in MultiSite Services. Auto Sp...
TANDBERG 7000 MXP 186 4.7.2 Encryption Mode Auto The system will try to use the most secure encryption - AES, dependent on the capabilities of the other sites. For sites that do not support AES encryption, DES encryption will be tried. AES The system will try to use AES with 128 bits encryption when...
Administrator Settings 191 Advanced ISDN Settings Sub address Using a sub address enables you to connect up to eight ISDN terminals to the same ISDN telephone number and line. The terminals are addressed by using different sub addresses. To call a terminal with a sub address, separate the ISDN telep...
TANDBERG 7000 MXP 192 4.8.1.2 ISDN-PRI Settings To make sure your system will work properly using ISDN-PRI, configure the following settings: 1. Set PRI switch type 2. Enter PRI line number Note that the T1 format is predefined to ESF and the line code is B8ZS. This is not configurable. Number Range...
Administrator Settings 193 Example: Max Channels may be used for PRIs that are provisioned for a lower number of channels. High Channel, Low Channel and Search may be used for PRIs provisioned with specific requirements for B-channel usage. In the example above, the system will start searching for a...
TANDBERG 7000 MXP 194 Advanced ISDN-PRI Settings NSF is a non standard facility. Your network provider may require a service selection in your ISDN configuration. Enter the Service code here. Valid NSF service codes are from 1 to 31. Enter 0 to disable NSF service codes. Example: AT&T offers sev...
TANDBERG 7000 MXP 202 DNS Settings DNS Server 1-5 DNS Server defines the network addresses for DNS servers. Up to 5 addresses may be specified. If the network addresses are unknown, please contact your administrator or Internet Service Provider. DNS Domain Name DNS Domain Name is the default domain ...
TANDBERG 7000 MXP 204 Gatekeeper Settings Gatekeeper Discovery Auto The system will automatically try to register to any available gatekeeper. If a gatekeeper responds to the request sent from the codec within 30 seconds this specific gatekeeper will be used. This requires auto discovery on the gate...
Administrator Settings 205 CallManager Settings CallManager IP This is the CallManager IP-address that is used if you specify H.323 Call Setup: CallManager.
TANDBERG 7000 MXP 206 Advanced H.323 Settings The Advanced H.323 Settings only have an effect if they are supported by your IP infrastructure. NAT NAT, Network Address Translation, is used when a PC and a videoconferencing system are connected to a router with NAT support. NAT support in the videoco...
TANDBERG 7000 MXP 208 4.8.2.3 SIP Settings Mode On Setting the SIP mode to on will enable the system for incoming and outgoing SIP calls. Off Setting the SIP mode to off will disable incoming and outgoing SIP calls from the system. Display Name The Display name part of the SIP Address (URI) is usual...
Administrator Settings 209 Server Address The Server Address is the manually configured address for the outbound proxy and registrar. It is possible to use a fully qualified domain name, or an IP address. The default port is 5060 for TCP and UDP, but another one can be provided. Server Address: <...
TANDBERG 7000 MXP 210 Draft-ietf-avt-rfc2032-bis-06.txt - Draft for advanced video signaling including resolution and mpi. RFC 2190 RTP Payload Format for H.263 Video Streams RFC 2429 RTP Payload Format for the 1998 Version of ITU-T Rec. H.263 Video (H.263+) Draft-ietf-avt-rfc2429-bis-05.txt...
TANDBERG 7000 MXP 216 4.8.3 Network Profiles This menu consists of 7 network profiles; a prefix can be added for each profile. If you add a prefix to a profile, this prefix will automatically be added in front of the number being dialed. Example: 0 is added as a Call Prefix to the 2nd profile, ISDN....
Administrator Settings 217 4.8.4 Data Port The system provides up to two standard RS232 serial ports to allow a computer to be connected for data transfer and control purposes. Note that when connecting to a PC the connecting cable must be a straight through RS232 cable. Baud Rate, Parity, Databits ...
TANDBERG 7000 MXP 218 4.8.5 Restore Default Settings Restore Default Settings will restore all administrator settings. Note that this will not affect your Call Directory information, Network Type, Line Setup numbers or your SPID numbers.
5 Peripheral Equipment Using the optional peripheral devices outlined in this chapter and the many others available, you will be able to build your own applications for use with the system, thereby better integrating the system into your business environment. This chapter will explain how to connect...
TANDBERG 7000 MXP 230 All balanced inputs and outputs (A and B) use balanced line signals according to V.11 (RS422) and single ended signals in accordance with V.10 (RS423). For balanced signals a "0"=low voltage is defined as terminal A positive with respect to terminal B. For unbalanced si...
Peripheral Equipment 233 5.4 Additional Cameras Extra fixed Cameras You can connect extra fixed cameras to your system, for example, a whiteboard camera. Connect the video output of the additional camera to one of the available Video inputs on the system. Multiple controllable Cameras Attaching mult...
TANDBERG 7000 MXP 234 5.5 Additional Microphones If your environment is such that you require more than one microphone for your room, e.g. you have a whiteboard at a distance from your table microphone, it is possible to connect additional microphones to your system. See Appendix 4 for more informat...
TANDBERG 7000 MXP 238 The DNAM Loudspeaker Cabinet (Center Speakers)*: 3-way Center Speaker system Frequency range 50Hz - 20kHz 2 x 130mm low- and midrange loudspeakers, 8 ohms nominal, high quality 1 x 25mm dome tweeter, 6 ohms nominal, high quality Crossover filtered audio signals receiv...
TANDBERG 7000 MXP 240 5.7 Stereo Speaker Kit Note that the following applies only for systems with a stereo S/PDIF output. The Stereo Speaker Kit provides an pair of floor-standing loudspeakers in addition to the built-in DNAM . Using these speakers will enable stereo functionality in your system an...
TANDBERG 7000 MXP 244 5.10 XGA Monitors and Projectors (Optional) Some TANDBERG systems can be delivered with optional single or dual TV/XGA monitors. It can also be connected to any DVI/VGA/PAL or NTSC display. Note that this requires a system with minimum one DVI-I output.
Peripheral Equipment 247 5.13 Extended Display Identification Data (EDID) Extended Display Identification Data (EDID) is a VESA standard data format that will allow the system to communicate its capabilities, including vendor information like the supported VGA-formats and frequency range limits to a...
6 Appendices Appendices: Appendix 1: Technical Specification Appendix 2: Bandwidth Information Appendix 3: Environmental considerations Appendix 4: Guidelines for setting up videoconferencing rooms Appendix 5: Security Appendix 6: Using the file system Appendix 7: Web Interface Appen...
TANDBERG 7000 MXP 250 6.1 Appendix 1 Technical Specification SYSTEM COMPONENTS 2 x 30" widescreen LCD monitors, wireless remote control, Tracker, W.A.V.E. II camera, microphone, Audio ModuleTM, integrated cabling and stand MONITORS Dual 30" LCD monitors 16:9 high resolution widescreen format...
Glossary 253 6.2 Appendix 2 Bandwidth information for TANDBERG endpoints Model 8000MXP, 7000MXP 6000MXP, Maestro Bandwidth Point to point ISDN / IP Standard: 768 / 3072 Option: 1920 / 4096 Standard: 768 / 3072 Option: 1920 / 4096 MultiSite Total: 3072kbps 4x768 video + 4 audio 3x1536 video + no audi...
TANDBERG 7000 MXP 256 6.3 Appendix 3 Environmental considerations This section explains how to carry out basic adjustments and simple tests to ensure that you send and receive the best possible image and audio quality when using your system. Iris control and lighting By default the system camera wil...
Glossary 257 6.4 Appendix 4 Guidelines for setting up videoconferencing rooms The following are a set of guidelines to consider when either building a videoconferencing room, or using an existing room for videoconferencing. Lighting: Low Contrast desired for light intensity. No dark spots. Inten...
TANDBERG 7000 MXP 262 6.6 Appendix 6 Using the file system It is possible to access a file system within the TANDBERG system by using ftp: DOS-window: ftp <IP-address of system>, or Web-browser: ftp:// <IP-address of system> Description of the different files: all.prm all settings in the...
Glossary 263 6.7 Appendix 7 Web Interface It is possible to access and maintain the system remotely via a local area network (LAN) using a standard Web-browser. Connect your system to a LAN with a Network cable. How to configure your system for web interface: 1. Open Administrator Settings and choos...
TANDBERG 7000 MXP 264 6.8 Appendix 8 (Not available on all TANDBERG systems) Connecting the system to PRI/T1 Using CSU adapter Connecting the system to the ISDN network via the E1/T1-interface using an Adtran T1 ESF CSU ACE or equivalent CSU, will allow up to 1.54 Mbps connection. The E1/T1-interfac...
Glossary 265 6.9 Appendix 9 Connecting the system to the Switched 56 network Using Telesync TS-256 SW56/ISDN adapter Connecting the system to the SW56 network using a Telesync Adapter is described below. There are different Telesync Adapters for different configurations of SW56 networks. The network...
TANDBERG 7000 MXP 272 6.13 Appendix 13 Cisco CallManager registration Configuring an H.323 client on the CallManager 4.0 The registration of a H.323 client in CallManager is supported on the CallManager (CCM) 4.0 software and forward. 1. To configure the CallManager with an H.323 client, log on to t...
Glossary 273 6.14 Appendix 14 Diagnostic Tools for IP To use these tools, will require using a PC and setting up a telnet session towards the system. Q.931 To show Q.931 trace during a call you need to issue the command ‘syslog on’.One can get traces for RAS, Q.931 and H.245 with this command. It is...
Glossary 275 6.15 Appendix 15 System Upgrade Before starting the software upgrade of the TANDBERG MXP system, please make sure to have the new software file, (for instance s050000F30.pkg) and the Release Key for this software available. Your TANDBERG Partner will provide this for you. All options an...
Glossary 283 7 Glossary # 199 AV1: External input for the TANDBERG/LOEWE monitor. 2nd monitor: The second monitor of your videoconferencing system. The second monitor is normally placed on the right side of the first monitor. 4CIF: 4 times CIF, 704x576 pixels 4SIF: 4 times SIF, 704x480 pixels A AACL...
TANDBERG 7000 MXP 292 8 Index A Access Code......................................94, 119 Add Another Call........................................40 Additional microphone .............................234 Administrator Password...........................135 Alert Speaker .................................
TANDBERG Manuals
-
TANDBERG 7000
Manual
-
TANDBERG EX90
Manual
-
TANDBERG E5740
Manual
-
TANDBERG D11624
Manual
-
TANDBERG MXP
Manual
-
TANDBERG Intern MXP
Manual
-
TANDBERG D13922.06
Manual
-
TANDBERG 2000MXP
Manual
-
TANDBERG 1500MXP
Manual
-
TANDBERG 880 MXP
Manual
-
TANDBERG MSE 8510
Manual
-
TANDBERG D14306.01
Manual
-
TANDBERG Utility
Manual
-
TANDBERG 6000 MXP
Manual
-
TANDBERG D1440902
Manual
-
TANDBERG D13751.01
Manual
-
TANDBERG D12809
Manual
-
TANDBERG D1392602
Manual
-
TANDBERG MPS 200
Manual
-
TANDBERG TC2.1