TANDBERG 6000 MXP Profile ii Trademarks and Copyright All rights reserved. This document contains information that is proprietary to TANDBERG. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, electronically, mechanically, by p...
User Manual iii Environmental Issues Thank you for buying a product, which contributes to a reduction in pollution, and thereby helps save the environment. Our products reduce the need for travel and transport and thereby reduce pollution. Our products have either none or few consumable parts (chemi...
TANDBERG 6000 MXP Profile iv Operator Safety Summary For your protection, please read these safety instructions completely before operating the equipment and keep this manual for future reference. The information in this summary is intended for operators. Carefully observe all warnings, precautions ...
TANDBERG 6000 MXP Profile vi Contact us If you have any questions, comments or suggestions, please see the Online Support service at www.tandberg.net . It is also possible to send a fax or mail to the attention of: Product and Sales Support TANDBERG P.O. Box 92 1325 Lysaker Norway Tel: +47 67 125 12...
User Manual vii Table of Contents 1 Introduction ............................................................................................................................. 11 1.1 At a Glance .............................................................................................................
1 Introduction The TANDBERG 6000 MXP Profile provides high-end performance features, large monitors and precision audio. This creates a collaborative meeting environment for medium to large-sized meeting rooms. Audio Quality High-performance audio provides a richer, more complete visual communicatio...
2 Installation Precautions: Never install communication wiring during a lightning storm. Never install jacks for communication cables in wet locations unless the jack is specifically designed for wet locations. Never touch uninstalled communication wires or terminals unless the telephone line ...
Installation 21 2.1 Unpacking and Mounting Unpacking To avoid damage to the unit during transportation the system is delivered as separate components: System Column and Foot Base, optional High quality monitor Wall Brackets Camera Camera stand The Accessories box contains the following...
Installation 23 2.2 Connecting Cables All cables needed in standard configuration are already connected to the codec. Connect these cables to their respective parts of the system. 1. Power cables Connect the power cable to an electrical distribution socket. 2. Monitor cables Connect the DVI cable to...
TANDBERG 6000 MXP Profile 24 2.3 Monitor Configuration The monitor is pre-configured and only needs to be switched on.
Installation 25 2.4 System Configuration The system must be configured for each installation. Configuration settings can be made via the system menu. If an external IMUX or non-standard network is being used it may be necessary to configure any associated external equipment. Navigate through the men...
3 General Use Wake up the system When the system is not in use, it is in standby mode and the screens are black. Wake up the system by picking up the remote control. An incoming call or pressing any key on the remote control will also wake up the system. If the system does not respond: Make sure t...
General Use 29 3.1 The Welcome Screen When the system is switched on, the welcome screen will be displayed. The welcome screen presents the menu and displays your main camera image in the background (main camera is system default). The ISDN/IP numbers and the system name are displayed in the upper r...
TANDBERG 6000 MXP Profile 30 3.2 Using the Remote Control The system is controlled with a remote control. Think of the remote control as a mobile phone with number keys and call keys. Use the arrow keys and OK to navigate the menu. The system ’ s most commonly used functions are also accessible dire...
TANDBERG 6000 MXP Profile 32 3.2.1 Navigation Arrow keys and OK Navigate in the menu with the arrow keys on the remote control. The orange selector on screen shows the selected item. Press OK to select. Cancel key In the main menu, pressing Cancel (X) will hide the menu. If the menu is hidden, bring...
General Use 35 3.2.3 Layout The layout of the screen can either be shown as Picture in Picture (PIP) or Picture outside Picture (POP) when displaying more than one video image. The behaviour of the Layout button is dependent on the Picture Layout setting in Screen Settings . 3.2.3.1 Picture in Pictu...
TANDBERG 6000 MXP Profile 36 3.2.4 Mic Off To mute the microphone during a call, press the Mic off button. An on-screen indicator appears in the upper right corner when the microphone is off. In a call, if audio is detected, the on-screen symbol will start to flash. Pressing the Mic off button one m...
TANDBERG 6000 MXP Profile 38 3.2.6 Number and Letter keys Pressing a number key when outside a call will bring up the call menu. W hen in a call, the number keys are used for Camera Presets. Press a number and go to the corresponding Camera Preset (see Camera Presets ). However, when having an input...
General Use 39 3.2.7 Touch Tones If wanting to dial extension numbers during a call, press the Touch tones button to activate the number keys, otherwise the number keys will activate the corresponding camera presets. An indicator will tell that Touch tones are enabled. Finish with OK to exit Touch t...
General Use 45 3.5.1 Place Video Call In the Make a Call menu enter the Dial Number either: 1. Manually, or 2. Select the book symbol in order to display the Phone Book and select a conference participant. When dialing manually, toggle between ABC/abc by pressing the # button on the remote control a...
TANDBERG 6000 MXP Profile 46 3.5.2 Place Telephone Call In the Make a Call menu enter the Dial Number either: 1. Manually, or 2. Select the book symbol in order to display the Phone Book and select a conference participant, see Phone Book for details. When entering a Dial Number manually, toggle bet...
General Use 47 3.5.3 Add Call (optional feature) Conference systems with built-in MultiSite can handle up to 6 video calls and 5 telephone calls simultaneously. It is possible to both set up a conference with many participants and also add participants during a conference. Set up a conference with t...
General Use 49 3.5.4 Call Settings The Call Settings specifies the quality of the call. Each call will be set up with the Default Call Settings if the settings are not altered. In this case the field is named Default Call Settings. If the settings for some reason are altered for the current particip...
TANDBERG 6000 MXP Profile 50 3.5.5 Streaming Streaming lets you broadcast your meeting to participants on web. The web participants can listen to the meeting, see snapshots, but not participate themselves. Snapshots of current stream (if MultiSite), selfview, far end and DuoVideo streams are accessi...
TANDBERG 6000 MXP Profile 52 3.6 Answer an incoming call How to answer an incoming call: To accept an incoming call, press the OK button or the green Call button on the remote control. How to reject an incoming call: To reject an incoming call, select the Reject icon and press the OK button, or ...
General Use 55 3.8.1 Delay Standby for 1 hour Delay Standby for 1 hour postpones the system from entering standby mode for 1 hour. This function is useful when using the monitors for a local presentation to prevent the system from automatically blanking the monitors. It is also possible to postpone ...
TANDBERG 6000 MXP Profile 56 3.8.2 Delay Standby for 3 hours Delay Standby for 3 hours postpones the automatic standby mode for 3 hours. This function is useful when using the monitors for a local presentation to prevent the system from automatically blanking the monitors. It is also possible to pos...
General Use 57 3.8.3 Do Not Disturb To prevent the system from accepting any incoming calls, the function Do Not Disturb has to be activated. The caller will hear a busy tone when calling the system. The monitor will be black when Do Not Disturb is active, see figure below. End Do Not Disturb by pre...
TANDBERG 6000 MXP Profile 60 3.9.1 Call Log The Call Log lists Last Number Dialed, Missed Calls and Call History allows the user to see which calls that are made in the past. The lists contain a maximum of 30 numbers and the numbers are stored in these lists until the system is restarted. If the con...
General Use 61 3.9.2 My Contacts My Contacts are the locally stored contacts on the system. This means that it is possible to add new contacts and edit or delete existing contacts. My Contacts can store up to 200 contacts. How to make a call using My Contacts: 1. Find the desired contact using the a...
General Use 63 3.9.2.1 Add New Contact The New Contact function is available from My Contacts . Add a new contact to My Contacts by: 1. Select the New Contacts button to open the New Contacts dialog box. 2. Enter Name by using the letter keys on the remote control. Input will automatically be interp...
TANDBERG 6000 MXP Profile 64 3.9.2.2 New MultiSite Contact (Optional feature*) The New MultiSite Contact function is available from My Contacts . It is possible to pre-define the participants of a conference meeting as a MultiSite Contact. All participants in the MultiSite Contact will then be conne...
TANDBERG 6000 MXP Profile 66 3.9.2.3 Edit Contact The Edit Contact function is available from My Contacts . How to edit a contact in the Local Phone Book: 1. Select the contact that is to be edited. 2. Press the left arrow on the remote control, followed by the down arrow until the Edit Contact icon...
General Use 67 3.9.2.4 Delete Contact The Delete Contact function is available from My Contacts . How to delete a contact: 1. Select the contact that is to be deleted. 2. Press the left arrow on the remote control, followed by the down arrow until the Delete Contact icon is selected. The Delete Cont...
TANDBERG 6000 MXP Profile 68 3.9.3 Global Contacts When selecting Phone Book the phone book opens showing the Global Contacts or the Corporate Directory, below the folders Last Number Dialled, Missed Calls, Call History and My Contacts. Global Contacts are available if the system is connected to an ...
TANDBERG 6000 MXP Profile 70 3.9.3.2 Search The phone book can contain an unlimited amount of global contacts. Using search makes it easier to find the wanted contact. How to search in the Global Phone Book: 1. Select the Search icon. 2. Enter search text in the dialogue box that appears and press t...
General Use 71 3.9.3.3 Copy Contact to My Contacts The Copy Contact to My Contacts function is available from the Last Number Dialed, Missed Calls, Call History and Global Contacts folders, see Phone Book for details. It may be wise to copy contacts that are often used to My Contacts. Note that the ...
General Use 73 3.10.1 Move Camera It is possible to move the camera with the remote control or via the menu. Moving the camera directly with the remote control When the menu is hidden, the arrow keys will work on the camera. If the menu is displayed, press the Cancel button on the remote control to ...
TANDBERG 6000 MXP Profile 74 3.10.2 Far End Control Far End Control allows you to control your conference partner ’ s camera. Far End Camera Control is useful if e.g. it is not possible to see what a participant at the far end is writing on their white board. Use Far End Control to move the far end ...
TANDBERG 6000 MXP Profile 76 preset on that number. 3.10.4 TANDBERG Tracker How to save presets for the TANDBERG Tracker: 1. Select which camera preset to be used on the TANDBERG Tracker. 2. Move the camera to the desired position to store on the tracker. 3. Select Move Camera - Save New Preset in t...
General Use 77 3.10.5 Picture Control Focus, Brightness and White balance are set for auto focus, auto brightness and auto white balance by default. If you need to set focus, brightness and white balance manually, go to Picture Control in the Camera Control menu. Focus Auto Auto focus continuously u...
TANDBERG 6000 MXP Profile 78 3.10.6 Camera Tracking Through Camera Tracking and the use of two or three microphones, the camera can automatically position itself on the current speaker. Before using camera tracking, the camera positions used must be stored at Preset 7 (Mic1), Preset 8 (Mic2) and/or ...
TANDBERG 6000 MXP Profile 80 3.11.1 Presentation Key The quickest way to show a presentation is to use the presentation key on the remote control. The presentation key is used to start and stop a presentation. The presentation key will display PC (default*) or the last used presentation source. When...
General Use 81 3.11.2 Presentation Menu The Presentation menu offers you all available video sources; Main Camera, PC, Document Camera, VCR, AUX and VNC. All these sources can be used as Main Video Stream or Dual Video Stream (Duo Video / H.239). Not all systems has all video sources available, see ...
General Use 83 3.11.4 PC Soft Presenter and VNC (Optional feature) PC SoftPresenter is used to display PC images on your system without using a VGA cable (PC Presenter). The system and your PC must be connected to the same LAN. In addition, VNC (Virtual Network Computing) server software must be ins...
General Use 85 3.11.6 Take New Snapshot The system can take a snapshot of your live video. Snapshot is handy when you are in a call with a system that does not support Dual Stream. Use Snapshot to show a snapshot of your presentation and continue the meeting with main camera. How to use snapshot: Yo...
TANDBERG 6000 MXP Profile 86 3.11.7 Display Snapshot The system stores the last sent or received Snapshot. The snapshot is deleted automatically after the call. How to display snapshots: 1. To view a stored snapshot, first choose the Snapshot header. 2. Select Display Snapshot in the Presentation me...
General Use 87 3.12 Conference Services A Multipoint Control Unit (MCU) enables several sites to participate in the same conference. During an MCU conference, the status line will provide information about the conference. You can make a multipoint conference in different ways. The Conference Service...
TANDBERG 6000 MXP Profile 90 3.12.1 Request Floor and Release Floor When requesting floor, your video will be broadcasted in full screen to all other participants in the conference. Request Floor is useful when you want to speak or display something in front of all participants. Release Floor when y...
General Use 91 3.12.2 Conference Layout (Only supported by TANDBERG MultiSite*) With a TANDBERG MultiSite you can choose between the layouts: Auto Split, 4 Split, 5+1 Split and Voice Switched view. Auto Split displays all participants on the screen simultaneously. 4 Split displays the 4 last speakin...
TANDBERG 6000 MXP Profile 92 3.12.3 Terminal Names Choose Terminal Names to see a list of the participants of the MultiSite conference. Press Cancel to go back.
General Use 93 3.12.4 Chair Control (Not supported by TANDBERG MCU, TANDBERG MPS or MultiSite) As chairman, you have access to more MultiSite Services. Select Chair Control to assume the role of chairman of the conference. Select Release Chair to end the role as chairman. A Chair indicator appears w...
General Use 95 3.12.6 View Site and End View (Not supported by TANDBERG MCU or MultiSite) View Site allows you to view any participant in the conference regardless of whom having floor and chair. Choose End View to go back to normal.
TANDBERG 6000 MXP Profile 96 3.12.7 Disconnect Participant Disconnect Participant allows the chairman to disconnect any participant in the conference. In a multipoint call, this is equivalent to disconnecting a participant from the end call menu.
General Use 97 3.12.8 Terminate Meeting Terminate Meeting allows the chairman to terminate the conference altogether. In a MultiSite call, this is equivalent to pressing End All Calls from the end call menu.
General Use 101 3.13.1 Diagnostics Diagnostics allows testing of individual system components and displays the current system settings. Diagnostics contain: System Information Channel Status Call Status System Selftest View Administrator Settings IP Address Conflict Check Warnings
TANDBERG 6000 MXP Profile 114 3.13.2 Text Chat While in an ISDN or IP call to another system supporting Text Chat (T.140), select Text Chat from the Control Panel. Enter text in the displayed window. How to use Text Chat: 1. Choose Text Chat from the Control Panel to open the Text Chat window. 2. En...
General Use 115 3.13.3 Audio Demo Note that the Audio demo will only appear in the User Guide if a Digital Natural Audio Module is connected to the codec.
General Use 117 3.13.5 Restart Restart the system by pressing the Restart button. You are prompted with a dialog box saying: Do you want to restart the system? Press OK to restart, press Cancel (X) to abort.
TANDBERG 6000 MXP Profile 118 3.13.6 User Guide The on screen user guide takes you through a quick step-by-step introduction to videoconferencing. It gives the user basic skills in how to use the system.
4 Administrator Settings Administrator Settings contain all the settings of the system. Making changes to Administrator Settings will change the behavior of the system. It is recommended to password protect the access to Administrator Settings to prevent occasional users from making crucial changes ...
TANDBERG 6000 MXP Profile 120 4.1 General Settings When installing the system, go through the General Settings menu to ensure that you have the right settings for your system, see System Configuration. General Settings contain: Language System Name Dual Monitor Autoanswer Max Call Length ...
Administrator Settings 121 4.1.1 Language The system supports 15 different languages for its on-screen menus; English, German, French, Norwegian, Swedish, Italian, Spanish, Portuguese, Chinese Simplified, Chinese Traditional, Japanese, Russian, Korean, Finnish and Thai. Select the preferred language...
TANDBERG 6000 MXP Profile 122 4.1.2 System Name System Name identifies the system: On the welcome page. During an MCU conference call. When using the Web-interface. When the codec is acting as an SNMP Agent. Towards a DHCP server. H323 ID. Other systems can call in using this name instea...
Administrator Settings 123 4.1.3 Dual Monitor TANDBERG systems can be used with both one and two monitors. If you use two monitors, make sure that Dual Monitor is set to "On". On Selfview, snapshots and Dual Stream will be displayed on the second monitor. Off The second monitor shows selfvie...
Administrator Settings 125 4.1.5 Max Call Length This feature will automatically end both incoming and outgoing calls when the call time exceeds the specified Max Call Length. Max Call Length can have the following values: 0-999 (minutes), where 0 means off.
TANDBERG 6000 MXP Profile 126 4.1.6 Phone Book Settings Corporate Directory On The Corporate Directory is available in the menu. Off The Corporate Directory is hidden from the menu and is unavailable for users. IP address Enter the IP address of the management system that provides the Phone Book. Pa...
Administrator Settings 127 4.1.7 Permissions Permissions contains settings for incoming MCU Calls, incoming telephone Calls, Far End Control, Remote Software Upgrade and Fallback to Telephony. Access Code An access code will help you control the use of the system. All users must enter a code to iden...
Administrator Settings 137 4.2.1 Menu Timeout In Call Main menu appears on the bottom line of the screen. Set Menu Timeout In Call to On if you want the menu to time out automatically when you are in a call. On The menu will time out automatically after 15 seconds if there is no activity on the remo...
TANDBERG 6000 MXP Profile 138 4.2.2 Welcome Menu The Welcome Menu contains the Main Menu, System Status, your System Name and dial in numbers. On The Welcome Menu is shown when the system wakes up from standby mode. Off The Welcome Menu is not shown when the system wakes up from standby mode. Press ...
Administrator Settings 139 4.2.3 Welcome Picture The Welcome Picture is what you see in the background of the welcome menu. Selfview Selfview is shown in the background of the welcome menu. In most cases this means that main camera is displayed and you can see the video image of yourself. Off No pic...
TANDBERG 6000 MXP Profile 140 4.2.4 Logo It is possible to upload a company logo to the system. For more information about how to upload a Logo, see Appendix 6 . Set the Logo settings to On to display the logo. On Choose On if you want the company logo to appear in the background of the welcome menu...
Administrator Settings 141 4.2.5 Menu on TV The Menu on TV setting decides if the menu shall be displayed on the TV screen or not. For optimal layout of the menu, Menu on TV should be Off if Menu on PC is On and vice versa. On The menu is available on the TV screen. Off The menu is not available on ...
TANDBERG 6000 MXP Profile 142 4.2.6 Menu on PC The Menu on PC setting decides if the menu shall be displayed on the PC (VGA screen) screen or not. For optimal layout of the menu, Menu on TV should be Off if Menu on PC is On and vice versa. On The menu is available on the PC screen. Off The menu is n...
Administrator Settings 143 4.2.7 Balloon Help It is possible to enable / disable the balloon help window. On Choose On if you want help text windows to appear. Off There will be no help text window.
TANDBERG 6000 MXP Profile 144 4.2.8 Display Welcome Text The welcome text displays your system name and dial in numbers by default. It is possible to hide this information by choosing Display Welcome Text Off. On Welcome text is displayed on the welcome menu. Off Welcome text is not displayed on the...
Administrator Settings 145 4.2.9 Welcome Text You can change the welcome text to any text you like, instead of the default text. Remember that Display Welcome Text must be On to be able to edit the welcome text.
TANDBERG 6000 MXP Profile 146 4.2.10 Administrator Password It is recommended to put an Administrator Password on the system. The Administrator Password can be maximum 5 digits long. The Administrator Password dialog box will pop up when you choose Administrator Settings from the Control Panel. This...
Administrator Settings 147 4.3 Presentation Settings Presentation Settings contain: Presentation Start H.239 Startup Video Source Presentation Source Snapshot Source Auto-Display Snapshot PIP Appearance PIP Placing VNC Settings
TANDBERG 6000 MXP Profile 148 4.3.1 Presentation Start If your system has Dual Stream capabilities, you can show two video streams at the same time (see also Dual Stream ). Presentation Start is Auto by default. This means that you will start Dual Stream (a second video stream) automatically when st...
TANDBERG 6000 MXP Profile 150 4.3.3 Startup Video Source The Startup Video Source is the video source on display when the system wakes up from standby mode. If you use Main Camera as start up source, the system will start with Main Camera every time the system wakes up from standby, regardless of wh...
Administrator Settings 151 4.3.4 Presentation Source The Presentation Source is connected to the Presentation button on the remote. Pressing the Presentation button will put the Presentation Source on display. Presentation Source is PC by default*. You can change the Presentation Source to any video...
TANDBERG 6000 MXP Profile 152 4.3.5 Snapshot Source When you take a Snapshot, you get a snapshot of the Snapshot Source. Current is the default Snapshot Source. This means that you take a snapshot of the video source that is currently active. You can change the Snapshot Source to any video source. I...
Administrator Settings 153 4.3.6 Auto-Display Snapshot Select Auto to automatically display a received snapshot. Turn Auto-Display Snapshot Manual if you wish not to have them displayed on the screen when they are sent or received. The snapshots will be sent and received, but not displayed. With Aut...
TANDBERG 6000 MXP Profile 154 4.3.7 PIP Appearance A Picture in Picture (PIP) is a smaller picture placed in one of the corners of the screen. The PIP enables you to see an extra picture in your video conference. Auto PIP Auto means that Picture In Picture will appear automatically when it is suitab...
Administrator Settings 155 4.3.8 PIP Placing PIP Placing lets you decide where the PIP shall appear. You can of course move the PIP with the Layout button on the remote anytime. Top Right PIP is placed in the Top Right corner. Bottom Right PIP is placed in the Bottom Right corner. Bottom Left PIP is...
TANDBERG 6000 MXP Profile 156 4.3.9 VNC Settings VNC Settings is necessary when using a VNC presentation. See chapter PC Soft Presenter and VNC for more information on how to use VNC. Address The IP-address of the PC with the VNC software installed. To find the IP-address of the PC, place the mouse ...
TANDBERG 6000 MXP Profile 158 4.4.1 Video Algorithm The system will automatically select the best video algorithm based on the video source and the capabilities of the remote system. Use this menu to disable video algorithms in case you have interoperability issues calling other systems. H.264 Bandw...
Administrator Settings 159 4.4.2 Audio Algorithm The system will automatically select the best audio algorithm based on the call rate and the capabilities of the remote system. Use this menu to disable audio algorithms in case you want to remove “ low quality ” audio, or if you have interoperability...
Administrator Settings 161 4.4.4 Natural Video Choosing Natural Video will enable 60 fields* per second true interlaced picture for high motion video. The use of Natural Video requires the H.263+ and H.263++ video protocols. Natural video will be disabled in H.323 MultiSite calls and in H.320 Contin...
Administrator Settings 163 4.4.6 Video Quality The different video sources need different Video Quality Settings. Main Camera, VCR, AUX and Split Screen have Motion as default. PC, Document Camera and VNC have Sharpness as default. Motion Optimized for smooth motion video (CIF/SIF for low bandwidths...
Administrator Settings 169 4.5.1 Inputs Mic 1- 3 and Audio input 4-6 By default, all inputs are enabled. Just plug in an audio source and it is active. Audio inputs that are On will automatically be mixed. Unconnected inputs will automatically be muted. Select Off to prevent audio/noise from connect...
Administrator Settings 171 4.5.2 Outputs Audio out 1 - 3 Audio out 1 is intended for connection to TANDBERG Digital Natural Audio Module, televisions or audio amplifiers. Audio out 2 is intended for connection to audio recording equipment or to a telephone add-on hybrid. The signal is a mix of audio...
TANDBERG 6000 MXP Profile 172 4.5.3 Echo Control Mic 1-3 and Audio 4 Each of the 3 microphone inputs and Audio input 4 has a separate acoustic echo canceller. One echo canceller per input provides more sophisticated control than having one common canceller for all microphones. In addition to echo ca...
Administrator Settings 177 4.5.6 Alert Tones and Volume Video Call Alert Tone and Telephone Alert Tone To help distinguish between incoming video calls and ordinary telephone calls, it is recommended to use different ringing tones for video calls and telephone calls. Alert Volume You may change the ...
TANDBERG 6000 MXP Profile 180 4.6.2 MCU Status Line On The MultiSite / MCU / DuoVideo indicators will be displayed and provide information about the conference. Off The MultiSite / MCU / DuoVideo indicators will not be displayed. Auto The MultiSite / MCU / DuoVideo indicators will be displayed for a...
Administrator Settings 181 4.6.3 Floor to Full Screen When "Floor to Full Screen" is enabled, someone who requests floor will be seen by all participants as full screen. When "Floor to Full Screen" is "Off", someone who request floor in a MultiSite conference using the 5+1 la...
TANDBERG 6000 MXP Profile 182 4.6.4 Web Snapshots The system is able to generate JPEG snapshots and provide them to the world outside by request (as ‘ http get ’ or via ftp). See Appendix 6 for descriptions of the possible snapshot files. On Snapshots generation is enabled. Off Snapshots generation ...
Administrator Settings 183 4.6.5 MultiSite Picture Mode MultiSite* Picture Mode decides the default layout of a MultiSite call. Choose between the layouts: Auto Split, 4 Split, 5+1 Split, and Voice Switched. You can change the layout during a call using the layout option in MultiSite Services. Auto ...
Administrator Settings 185 4.6.6 Video Name As a default, the video inputs are given the names Main Cam, PC, Doc Cam, VCR, AUX or VNC, dependent on what video sources are available on your system. The video names cannot exceed eight characters. The names correspond to the video names in the Presenta...
Administrator Settings 187 4.7.1 Encryption (Country specific) Auto The system will try to set up calls using encryption. Point to point calls: If the far end system supports encryption (AES or DES), the call will be encrypted. If not, the call will proceed without encryption. MultiSite calls*: In o...
TANDBERG 6000 MXP Profile 188 4.7.2 Encryption Mode Auto The system will try to use the most secure encryption - AES, dependent on the capabilities of the other sites. For sites that do not support AES encryption, DES encryption will be tried. AES The system will try to use AES with 128 bits encrypt...
Administrator Settings 189 4.7.3 Passwords Administrator Password, IP Access Password, Streaming Password, VNC Password, Access Code and Remote Software Upgrade password are duplicated from their respective menus. Using the Security menu gives you a quick way to change all passwords of the system.
Administrator Settings 193 Advanced ISDN Settings Sub address Using a sub address enables you to connect up to eight ISDN terminals to the same ISDN telephone number and line. The terminals are addressed by using different sub addresses. To call a terminal with a sub address, separate the ISDN telep...
TANDBERG 6000 MXP Profile 194 4.8.1.2 ISDN-PRI Settings To make sure your system will work properly using ISDN-PRI, configure the following settings: 1. Set PRI switch type 2. Enter PRI line number Note that the T1 format is predefined to ESF and the line code is B8ZS. This is not configurable. Numb...
Administrator Settings 195 Example: Max Channels may be used for PRIs that are provisioned for a lower number of channels. High Channel, Low Channel and Search may be used for PRIs provisioned with specific requirements for B-channel usage. In the example above, the system will start searching for a...
TANDBERG 6000 MXP Profile 196 Advanced ISDN-PRI Settings NSF is a non standard facility. Your network provider may require a service selection in your ISDN configuration. Enter the Service code here. Valid NSF service codes are from 1 to 31. Enter 0 to disable NSF service codes. Example: AT&T of...
TANDBERG 6000 MXP Profile 200 4.8.2 LAN Settings LAN Settings contain: IP Settings H.323 Settings SIP Settings SNMP Settings IP Services Quality of Service
Administrator Settings 203 DNS Settings DNS Server 1-5 DNS Server defines the network addresses for DNS servers. Up to 5 addresses may be specified. If the network addresses are unknown, please contact your administrator or Internet Service Provider. DNS Domain Name DNS Domain Name is the default do...
Administrator Settings 205 Gatekeeper Settings Gatekeeper Discovery Auto The system will automatically try to register on any available gatekeeper. If a gatekeeper responds to the request sent from the codec within 30 seconds this specific gatekeeper will be used. This requires auto discovery on the...
TANDBERG 6000 MXP Profile 206 CallManager Settings CallManager IP This is the CallManager IP-address that is used if you specify H.323 Call Setup: CallManager.
Administrator Settings 207 Advanced H.323 Settings The Advanced H.323 Settings only have an effect if they are supported by your IP infrastructure. NAT NAT, Network Address Translation, is used when a PC and a videoconferencing system are connected to a router with NAT support. NAT support in the vi...
Administrator Settings 209 4.8.2.3 SIP Settings Mode On Setting the SIP mode to on will enable the system for incoming and outgoing SIP calls. Off Setting the SIP mode to off will disable incoming and outgoing SIP calls from the system. Display Name The Display name part of the SIP Address (URI) is ...
Administrator Settings 211 Draft-ietf-avt-rfc2429-bis-05.txt - Draft for advanced video signaling including resolution, mpi, annexes and custom formats. RFC 3047 RTP Payload Format for ITU-T Recommendation G.722.1 Media Capabilities supported in SIP: Audio: PCMU (G.711 u-law) PCMA (G.711 a-law) ...
TANDBERG 6000 MXP Profile 216 4.8.3 Network Profiles This menu consists of 7 network profiles; a prefix can be added for each profile. If you add a prefix to a profile, this prefix will automatically be added in front of the number being dialed. Example: 0 is added as a Call Prefix to the 2nd profil...
Administrator Settings 217 4.8.4 Data Port The system provides up to two standard RS232 serial ports to allow a computer to be connected for data transfer and control purposes. Note that when connecting to a PC the connecting cable must be a straight through RS232 cable. Baud Rate, Parity, Databits ...
TANDBERG 6000 MXP Profile 218 4.8.5 Restore Default Settings Restore Default Settings will restore all administrator settings. Note that this will not affect your Call Directory information, Network Type, Line Setup numbers or your SPID numbers.
5 Peripheral Equipment Using the optional peripheral devices outlined in this chapter and the many others available, you will be able to build your own applications for use with the system, thereby better integrating the system into your business environment. This chapter will explain how to connect...
TANDBERG 6000 MXP Profile 220 5.1 Interfaces 5.1.1 Video 5 Video Inputs: 2 video inputs supporting S-Video through Mini-DIN connectors. 2 video inputs supporting composite signals through RCA connectors. 1 VGA/DVI-I (DVI = Digital Video Interface, I = Integrated Digital & Analog) input sup...
TANDBERG 6000 MXP Profile 230 5.1.4 Data port The data port(s) are implemented as Data Communications Equipment (DCE). The connector used are female 9-pin D-subs. The TANDBERG main camera is normally connected to data port 2 and pin number 4 provides 12V DC / 1 Amps to the main camera. Otherwise the...
TANDBERG 6000 MXP Profile 234 5.4 Additional Cameras Extra fixed Cameras You can connect extra fixed cameras to your system, for example, a whiteboard camera. Connect the video output of the additional camera to one of the available Video inputs on the system. Multiple controllable Cameras Attaching...
Peripheral Equipment 235 5.5 Additional Microphones If your environment is such that you require more than one microphone for your room, e.g. you have a whiteboard at a distance from your table microphone, it is possible to connect additional microphones to your system. See Appendix 4 for more infor...
Peripheral Equipment 237 5.6 The TANDBERG DNAM and Speakers 5.6.1.1 TANDBERG 6000 MXP Profile, TANDBERG 6000 MXP, TANDBERG 7000 MXP, TANDBERG 8000 MXP and TANDBERG Maestro The TANDBERG Digital Natural Audio Module, DNAM*: The DNAM audiosystem is built on two specially designed and separate modules; ...
Peripheral Equipment 241 5.7 Stereo Speaker Kit Note that the following applies only for systems with a stereo S/PDIF output. The Stereo Speaker Kit provides an pair of floor-standing loudspeakers in addition to the built-in DNAM . Using these speakers will enable stereo functionality in your system...
Peripheral Equipment 245 5.10 XGA Monitors and Projectors (Optional) The system can be delivered with optional single or dual TV/XGA monitors. It can also be connected to any DVI/VGA/PAL or NTSC display. Note that this requires a system with minimum one DVI-I output.
Peripheral Equipment 247 5.12 Digital Monitor Power Management DMPM is monitor power management applied over the digital DVI interface. TANDBERG supports DMPM in software F2 and above. Six monitor power states are defined. Monitor On Power state: Transmitter (TANDBERG codec) and receiver (Monitor) a...
TANDBERG 6000 MXP Profile 248 5.13 Extended Display Identification Data (EDID) Extended Display Identification Data (EDID) is a VESA standard data format that will allow the system to communicate its capabilities, including vendor information like the supported VGA-formats and frequency range limits...
6 Appendices Appendices: Appendix 1: Technical Specification Appendix 2: Bandwidth Information Appendix 3: Environmental considerations Appendix 4: Guidelines for setting up videoconferencing rooms Appendix 5: Security Appendix 6: Using the file system Appendix 7: Web Interface Appen...
Appendices 251 6.1 Appendix 1 Technical Specification SYSTEM COMPONENTS 1 or 2 monitors, wireless remote control, Tracker, W.A.V.E. II camera, microphone, Audio ModuleTM, integrated cabling, cart MONITOR Pioneer 50" NTSC/PAL or Pioneer 43" NTSC/PAL Optional high-resolution monitors Other mon...
TANDBERG 6000 MXP Profile 254 6.2 Appendix 2 Bandwidth information for TANDBERG endpoints Model 8000MXP, 7000MXP 6000MXP, Maestro Bandwidth Point to point ISDN / IP Standard: 768 / 3072 Option: 1920 / 4096 Standard: 768 / 3072 Option: 1920 / 4096 MultiSite Total: 3072kbps 4x768 video + 4 audio 3x153...
Appendices 257 6.3 Appendix 3 Environmental considerations This section explains how to carry out basic adjustments and simple tests to ensure that you send and receive the best possible image and audio quality when using your system. Iris control and lighting By default the system camera will use a...
TANDBERG 6000 MXP Profile 260 6.5 Appendix 5 Security The system has several features both to protect from unauthorized use and system access: Access Code: When Access Code is enabled, the user will be asked to enter an access code before he/she is able to make a call. The system will verify if the ...
Appendices 263 6.6 Appendix 6 Using the file system It is possible to access a file system within the TANDBERG system by using ftp: DOS-window: ftp <IP-address of system>, or Web-browser: ftp:// <IP-address of system> Description of the different files: all.prm all settings in the system...
TANDBERG 6000 MXP Profile 264 6.7 Appendix 7 Web Interface It is possible to access and maintain the system remotely via a local area network (LAN) using a standard Web-browser. Connect your system to a LAN with a Network cable. How to configure your system for web interface: 1. Open Administrator S...
Appendices 265 6.8 Appendix 8 (Not available on all TANDBERG systems) Connecting the system to PRI/T1 Using CSU adapter Connecting the system to the ISDN network via the E1/T1-interface using an Adtran T1 ESF CSU ACE or equivalent CSU, will allow up to 1.54 Mbps connection. The E1/T1-interface must ...
TANDBERG 6000 MXP Profile 268 6.11 Appendix 11 (Not available with set top systems) WAVE II Camera Pinouts and Connectors 8-PIN RJ (shielded modular jack): This connector is used for the power and control signals to the main camera. Pin-8 +12V (presence when connected in daisy chain) Pin-7 GND Pin-6...
Appendices 273 6.13 Appendix 13 Cisco CallManager registration Configuring an H.323 client on the CallManager 4.0 The registration of a H.323 client in CallManager is supported on the CallManager (CCM) 4.0 software and forward. 1. To configure the CallManager with an H.323 client, log on to the admi...
TANDBERG 6000 MXP Profile 274 6.14 Appendix 14 Diagnostic Tools for IP To use these tools, will require using a PC and setting up a telnet session towards the system. Q.931 To show Q.931 trace during a call you need to issue the command ‘ syslog on ’ .One can get traces for RAS, Q.931 and H.245 with...
TANDBERG 6000 MXP Profile 276 6.15 Appendix 15 System Upgrade Before starting the software upgrade of the TANDBERG MXP system, please make sure to have the new software file, (for instance s050000F30.pkg) and the Release Key for this software available. Your TANDBERG Partner will provide this for yo...
Appendices 281 6.16 Appendix 16 Declaration of Conformity Please contact your TANDBERG representative for a Declaration of Conformity
TANDBERG 6000 MXP Profile 282 Appendix 17 Dimensions Front view, 50'' monitor
7 Glossary # 199 AV1: External input for the TANDBERG/LOEWE monitor. 2nd monitor: The second monitor of your videoconferencing system. The second monitor is normally placed on the right side of the first monitor. 4CIF: 4 times CIF, 704x576 pixels 4SIF: 4 times SIF, 704x480 pixels A AACLD: Advanced A...
8 Index A Access Code....................................102, 127 Add Another Call........................................ 47 Additional microphone ............................. 235 Administrator Password ........................... 146 Alert Speaker ........................................... 177 A...
TANDBERG Manuals
-
TANDBERG 7000
Manual
-
TANDBERG EX90
Manual
-
TANDBERG E5740
Manual
-
TANDBERG D11624
Manual
-
TANDBERG MXP
Manual
-
TANDBERG Intern MXP
Manual
-
TANDBERG D13922.06
Manual
-
TANDBERG 2000MXP
Manual
-
TANDBERG 1500MXP
Manual
-
TANDBERG 880 MXP
Manual
-
TANDBERG MSE 8510
Manual
-
TANDBERG D14306.01
Manual
-
TANDBERG Utility
Manual
-
TANDBERG 6000 MXP
Manual
-
TANDBERG D1440902
Manual
-
TANDBERG D13751.01
Manual
-
TANDBERG D12809
Manual
-
TANDBERG D1392602
Manual
-
TANDBERG MPS 200
Manual
-
TANDBERG TC2.1
Manual