Page 2 - IM; st
P A G E 2 /2 2 TA N D B E R G Telepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 TA N D B E R G Telepresence T3 S Y S T E M d IM E N S IO N S 1658 65 1 4 " T3 sy st em dimensions 2800 110 1 4 " 1650 65 " 1650 65 " 1500 59 " 2500 65 3 8 " 120 4 3 4 " 724 28 ...
Page 3 - Telepresence T3; IR
P A G E 3 /2 2 TA N D B E R G Telepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 R O O M d E P T H R E Q U IR E M E N T S O P T IM A l A N d M A x IM A l d E P T H 140 5 1 2 " 4600 181 1 8 " 4880 192 1 8 " 1015 40" 1000 39 3 8 " 1300 51 1 8 " Centerline Baselin...
Page 4 - IN; Observe that if the room gets smaller
P A G E 4 /2 2 TA N D B E R G Telepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 TA N D B E R G Telepresence T3 M IN IM U M R O O M d E P T H R E Q U IR E M E N T S 140 5 1 2 " 4120 162 1 4 " 4400 173 1 4 " 1015 40" 1000 39 3 8 " 1300 51 1 8 " Centerline Baseli...
Page 5 - Observe that the room should not have a smaller width than shown
P A G E 5 /2 2 TA N D B E R G Telepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 M IN IM U M R O O M W Id T H R E Q U IR E M E N T S Centerline Min room width 4800 189 " 6645 261 " 5 8 922,5 36 " 3 8 922,5 36 " 3 8 85 3 8 3 " 6815 268 " 1 4 85 3 8 3 " Obser...
Page 6 - optimal r
P A G E 6 /2 2 TA N D B E R G Telepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 TA N D B E R G Telepresence T3 O P T IM U M A N d M A x IM U M R O O M H E IG H T 2360 92 7 8 " 190 7 1 2 " 2550 100 3 8 " optimal r oom heigh t Note that the room is shown with the T eleprese...
Page 7 - minimum r
P A G E 7 /2 2 TA N D B E R G Telepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 M IN IM U M R O O M H E IG H T R E Q U IR E M E N T S 2360 92 7 8 " 40 1 5 8 " 2400 94 1 2 " minimum r oom heigh t Note that the room is shown with the T elepresence T3 system installed.
Page 8 - maximum r
P A G E 8 /2 2 TA N D B E R G Telepresence T3 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 M A x IM U M R O O M H E IG H T 2360 92 7 8 " 290 11 3 8 " 2650 104 3 8 " maximum r oom heigh t Note that the room is shown with the T elepresence T3 system installed.
Page 9 - TA N D B E R G; H VA C R E Q U I R E M E N T S; Power consumption System: 1725 W
PA G E 9 / 2 2 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 TA N D B E R G Telepresence T3 H VA C R E Q U I R E M E N T S The following HVAC (heating, ventilation, air-conditioning) requirements apply to the TANDBERG Telepresence T3: • Power consumption System: 1725 W • Power consumption Table:...
Page 11 - A C O U S T I C S R E Q U I R E M E N T S; REQUIREMENTS IN GENERAl; All walls around the room should have a sound insulation of R’w; REQUIREMENTS SPECIfIC fOR IMMERSIVE ROOMS; Absorptive ceiling should have an absorption factor α; REQUIREMENTS SPECIfIC fOR NON-IMMERSIVE ROOMS; The ceiling is recommended to have an absorption factor
PA G E 1 1 / 2 2 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 TA N D B E R G Telepresence T3 A C O U S T I C S R E Q U I R E M E N T S It is essential to have a good acoustic environment for the system to provide the true telepresence experience. This means that there should be sufficient sound...
Page 12 - P O W E R O U T l E T f U S E
PA G E 1 2 / 2 2 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 TA N D B E R G Telepresence T3 P O W E R O U T l E T f U S E R E Q U I R E M E N T S The following minimum power outlet fuse requirements apply to the TANDBERG Telepresence T3: ITEM WATT PlACEMENT fUSE ON/Off SWITCH T1 Module × 3 240...
Page 13 - E l E C T R O N I C V E R S I O N S O f; The following drawings are available:
PA G E 1 3 / 2 2 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 TA N D B E R G Telepresence T3 E l E C T R O N I C V E R S I O N S O f T E C H N I C A l d R AW I N G S The technical drawings on the following pages are also available in electronic formats as pdf, dwg and dxf. To obtain copies of t...
Page 14 - TANDBERG
P A G E 1 4 /2 2 119076.02 TELEPRESENCE T3 ROOM REQUIREMENTS 12.08 320 12 1 2 " 2247 88 1 2 " 2100 82 1 2 " 150 6" 2025 79 1 2 " 675 26 1 2 " 1000 39 1 2 " 1000 39 1 2 " 4930 194" 2240 88" Centerline Area where installation of aircondition should be avoided In...