Page 2 - PACKAGING; Millivolt; Use Only These Approved Vent Components:; GENERAL INfORMATION; Les enfants et les adultes devraient; WARNING; TABLE Of CONTENTS
SUPERIOR ® B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS Packaging .........................................Page 2Introduction ......................................Page 2General Information ..........................Page 2Gas Pressure Requirements ..............Page 4O...
Page 3 - Ne pas utiliser cet appareil s’il a été
SUPERIOR ® B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS Note: Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be requir...
Page 4 - Sea Level to High Altitude; deration
SUPERIOR ® B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS Figure 2 - Dexen Electronic Gas Valve Pilot Stage Terminal Pressure-Tap (Inlet) Pilot Gas Outlet Supply Gas Inlet Pressure-Tap (Manifold) Burner Stage Terminal Ground (TP) PILOT OUT VENT LO TH TP TH TP HI IN IN Re...
Page 5 - COLd CLIMATE INSULATION; When the unit is installed with one side
SUPERIOR ® B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS COLd CLIMATE INSULATION For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside...
Page 6 - VENT TERMINATION; Multiple Terminations; provided that any discharge opening on; Figure 4; Minimum Height from Roof to; Gas Vent Rule; Table 5
Termination Heights for Vents Above flat Or Sloped Roofs Ref. NfPA 54 / ANSI z223.1 Roof Pitch * feet * Meters Flat to 6/12 1.0 0.3 6/12 to 7/12 1.25 0.38 7/12 to 8/12 1.5 0.46 8/12 to 9/12 2.0 0.61 9/12 to 10/12 2.5 0.76 10/12 to 11/12 3.25 0.99 11/12 to 12/12 4.0 1.22 12/12 to 14/12 5.0 1.52 14/12...
Page 7 - MINIMUM CLEARANCES TO COMBUSTIBLES; Appliance and Vent Clearances; on all sides (as detailed in; Hearth Extension; is used, do not block the lower control compartment door. Any hearth
5 (127) 8-1/4 (209) 14 (356) 12 (305) 19 (483) 8 (203) 2 (51) 4 (102) 6 (152) 8 (203) 10 (254) 12 (305) 10 (254) 14 (356) 18 (457) 16 (406) 12 (305) Top of Appliance inches (millimeters) Mantel depth Note - Hood shown as positioned. Figure 6 - Minimum Mantel Clearances Header Figure 5 - Minimum Dist...
Page 8 - PRE-INSTALLATION STEPS; To remove the glass enclosure panel:; safe location to protect it from inadvertent; TYPICAL INSTALLATION; a. Millivolt Appliances: Install the; dETAILEd INSTALLATION STEPS; Step 1. Construct Appliance; fireplace secured to framing; Bend up the
PRE-INSTALLATION STEPS (Remove Glass Enclosure Panel) The appliance is shipped with all gas controls and components installed and pre-wired. Note: Remove the glass enclosure panel before installing the fireplace. To remove the glass enclosure panel: 1. Remove the shipping carton, and then re- move t...
Page 9 - fIREPLACE ANd fRAMING SPECIfICATIONS; photographs are not to scale. Product; Natural & Propane Gas; framing dimensions; fIREPLACE fRAMING SPECIfICATIONS; Construct framing with 2x4 or larger lumber.; Corner framing dimensions; CORNER fRAMING dIMENSIONS
SUPERIOR ® B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS fIREPLACE ANd fRAMING SPECIfICATIONS NOTE: Diagrams, illustrations and photographs are not to scale. Product designs, materials, dimensions, specifications, colors, and prices are subject to change or discontinuan...
Page 10 - VERTICAL VENTING THROUGH CEILING; fIREPLACE SPECIfICATIONS
SUPERIOR ® B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS VERTICAL VENTING THROUGH CEILING frame Ceiling Opening: To locate the center of the vertical run, use a plumb line from the ceiling above the appliance. Model No. in. mm SLBV-35 32-1/4 819 28-1/8 714 23-1/4 590 32...
Page 11 - Proper Sizing of Gas Line; Also see; Left Side Front; Step 2. Route the Gas Line; Step 3. Install Venting System; Required Pipe diameter; WARNING: EDGES OF SHEET METAL ARE; • Sheet Metal-resistant Gloves
Note: • All appliances are factory-equipped with a flexible gas line connector and 1/2 inch shutoff valve (see Figure 17 on Page 15 ). • See Massachusetts Requirements on Page 4 for additional requirements for installa- tions in the state of Massachusetts in the USA. • The gas supply line should NOT...
Page 12 - Step 4. Install field Wiring; CAUTION; Verify proper operation after installing.
SUPERIOR ® B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS 12 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Step 4. Install field Wiring CAUTION Ground supply lead must be con- nected to the wire attached to the green ground screw located on the outlet box. See Fig...
Page 13 - MILLIVOLT WIRING dIAGRAM; ELECTRONIC IGNITION WIRING dIAGRAM; Schematic Representation Only
SUPERIOR ® B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS 13 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 12 MILLIVOLT WIRING dIAGRAM CAUTION: WHEN SERVICING CONTROLS, LABEL ALL WIRES PRIOR TO dISCONNECTION. WIRING ERRORS CAN CAUSE IMPROPER ANd dANGEROUS O...
Page 14 - Install Outside; at right; INSTALLATION ACCESSORIES; Outside Combustion Air Kits; do not operate the shutoff lever; Left Side of; IMPORTANT: Do NOT move Air Control
SUPERIOR ® B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS Step 5. [OPTIONAL] Install Outside Combustion Air Kit An optional outside combustion air kit (model FOAK-4, FOAK-4LD, or DK-4) may be used with these appliances (see "Installation Acces- sories," at right ...
Page 15 - Step 6. Connect the Gas Line; Figure; Gas; Turn valve handle
SUPERIOR ® B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS Figure 17 Step 6. Connect the Gas Line All codes require a shut-off valve mounted in the supply line. The orientation of the shut- off valve should face the front. Figure 16 illustrates two methods for connecting ...
Page 16 - A. Light the appliance (refer to the lighting; Never use an open flame to; Step 7. Verify Appliance; Electronic Appliance Checkout
SUPERIOR ® B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS Turn on gas supply and test for gas leaks, us- ing a gas leak test solution (also referred to as bubble leak solution). Note: Using a soapy water solution is an effective leak test solution but it is not recom- me...
Page 17 - Place the glowing ember material; Separate into individual; and Logs; Remove the front glass enclosure panel
SUPERIOR ® B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS WARNING • dO NOT attempt to install the logs until the appliance installation has been completed, the gas line connected and tested for leaks and the initial burner operation has been checked out. • The size and p...
Page 18 - SLBV-35 LOG PLACEMENT INSTRUCTIONS; To prevent sooting, make sure logs do not cover any burner openings.
SUPERIOR ® B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS SLBV-35 LOG PLACEMENT INSTRUCTIONS Figure 23 Left Rear Brackets Step 1 Right Rear Bracket Glowing Embers (Do not place Glowing Embers over burner slots.) Step 2 Align hole at the bottom of left front log (1) over ...
Page 19 - SLBV-40 LOG PLACEMENT INSTRUCTIONS
SLBV-40 LOG PLACEMENT INSTRUCTIONS Figure 24 Left Rear Log Right Rear Log Ember Chunk Left front Log Right front Log 5 4 2 3 1 SLBV firebox Accessories/Parts Cat. No. Model No. description H7245 — SLBV-40 Log Set Assembly 88L53 fGE Bag of Glowing Embers (Rockwool) 80L42 fdVS Bag of decorative Volcan...
Page 20 - Only doors certified with the appliance; • Handle this glass with extreme; . To access the spring; Step 9. Install the Glass Enclosure; Step 10. Burner Air Shutter
SUPERIOR ® B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS Only doors certified with the appliance shall be used. Seules des portes certifiées pour cet appareil doivent être utilisées. CAUTION: dO NOT abuse glass enclosure panel by striking or slamming shut. Installing th...
Page 21 - Main Burner factory Air Shutter; Locate adjustment rod and adjust air shutter to the standard set-; Move the adjustment rod DOWN to decrease air; When satisfied that the burner flame appearance is normal, re-; Burner Air Shutter Adjustment Procedure
SUPERIOR ® B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS Main Burner factory Air Shutter Opening Setting - Inches (millimeter) Model Nat.Gas Propane Gas SLBV-35 1/32 (0.794) 1/16" (1.587) SLBV-40 1/32 (0.794) 3/16" (4.763) Adjustment Rod Up (fully Open Position)...
Page 22 - Step 11. Perform Spillage Test; Manually-Reset Safety Limit Switch; low to access the switch (also see; is between the
pull the switch/bracket assembly (with low voltage wires attached) through the side panel slot into the firebox. 8 - Replace the switch, if necessary..9 - Reinstall the scoop and lintel.10 - Reinstall the glass enclosure panel and control compartment access panel. The appliance should then relight a...
Page 23 - Step 12. Install Hood; NOTE: All models must have a hood installed; Step 13. finishing Requirements; Wall details; Top of Appliance; Figure 30: Combustible Wall Framing; Combustible finished; Combustible material; Hood; Bend up standoffs; Header
Step 12. Install Hood NOTE: All models must have a hood installed prior to operating. Refer to Figure 30 . Install hood by sliding it into the slots on the lower edge of the cabinet top . Step 13. finishing Requirements Wall details Complete finished interior wall. To install the appliance facing fl...
Page 24 - WARNINGS; ). To properly complete the installation of; Figure A; APPOSITION dES MISES EN GARdE RELATIVES
SUPERIOR ® B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS 24 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Step 14. Attach Safety-In-Operation Warnings It is the installer’s responsibility to ensure these warning labels are properly affixed during installation. Th...
Page 25 - GAS CONVERSION KITS; Gas Conversion Kit Installation; Electronic; assume les responsabilités liées à la conversion.
Millivolt SIT Systems Propane Gas to Natural Gas Conversion Kits Models Catalog No. SLBV-35 H8271 SLBV-40 H7675 Millivolt SIT Systems Natural Gas To Propane Gas Conversion Kits Models Catalog No. SLBV-35 H8270 SLBV-40 H7673 Electronic dEXEN Systems Propane Gas To Natural Gas Conversion Kits Models C...
Page 26 - Electronic Appliances; All Models
Electronic Appliances Step 8. dexen Electronic Valves: Refer to Figure 34 and the instructions pro- vided with the kit. a. Remove and discard the two pres- sure regulator mounting screws. b. Remove the pressure regulator and diaphragm. c. discard all removed components. d. Make sure the provided dia...
Page 27 - Notes
Notes SUPERIOR ® B-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS 27 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 28 - LENNOX HEARTH PROdUCTS
Printed in U.S.A. © 2010 Lennox Hearth Products P/N 506009-02 Rev. B 06/2011 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fir...