Page 2 - Ensure Suitability Of Location; Check Gas Type; Before Installation
2 Ensure Suitability Of Location Before making any alterations to kitchen cabinetry, you should ensure that the proposed location for the cooktop is suitable: Electrical supply: there must be an earthed 240V 50 Hz 10Amp power socket within reach of the supplied electrical cable (approximately 850mm ...
Page 3 - Clearances
3 Clearances Overhead Clearances Rangehoods and overhead exhaust fans must be installed with at least the clearances recommended by the manufacturer’s instructions, but in all cases the clearance from the top of the highest burner to a rangehood must be at least 650mm, and to an exhaust fan must be ...
Page 4 - Installation Details; Lay The Rubber Seal; Attach The Duplicate Data Label
4 Installation Details Lay The Rubber Seal Rubber sealing material has been provided to help seat the edges of the cooktop neatly onto the benchwork.The cooktop must not be bonded to the benchwork with any adhesive or permanent sealant, as this will prevent future servicing and maintenance work to b...
Page 5 - Connect The Gas; Attach The Burner Head And Burner Cap
5 Connect The Gas For gas appliances, the fi nal gas connection must be made using a fl exible hose or annealed copper tubing of suf fi cient length to permit the insertion and removal of the appliance. The gas Inlet fi tting is ½ “ BSP (male) thread. If a fl exible hose is used. Install with a hose...
6 Check For Leaks Once the appliance is installed, conduct a full gas soundness check according to the requirements of AS5601. Whenever any change to the installation is made that may affect gas soundness (eg adjustments involving any disconnection and reconnection), then follow the following leak t...
Page 7 - Check Turn Down Settings And Adjust If Necessary; Gas Conversion; Change The Injectors
7 Connect The Appropriate Regulator For natural gas installations, use only the regulator supplied with the cooktop. ULPG installations that have pressure control regulators at the supply cylinder do not require a separate appliance regulator. However, a test point adaptor must be connected to the g...
Page 8 - Basic Servicing; Removing The Hob
8 St George Appliances3-5 Birmingham Ave Chester Hill NSW 2162ph 1300-305-366www.sga.com.au 556xx00_instal_0106 Basic Servicing Ensure all gas and electricity is completely disconnected from the appliance, and all components have cooled down from any previous use.Remove the trivets, burner caps and ...