Page 3 - Contents
Momentus 5400.3 SATA Blade Server Product Manual, Rev. E i Contents 1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 About the Serial ATA interface . . . . . . . . . . . . . . . . . . . . . . ...
Page 4 - ii
ii Momentus 5400.3 SATA Blade Server Product Manual, Rev. E
Page 5 - iii; List of Figures
Momentus 5400.3 SATA Blade Server Product Manual, Rev. E iii List of Figures Figure 1. Typical +5V startup and operation current profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Figure 2. Serial ATA connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 7 - Introduction; Momentus
Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 1 1.0 Introduction This manual describes the functional, mechanical and interface specifications for the following Seagate Momentus ® 5400.3 SATA Blade Server model drives: • ST9160821SB • ST9120822SB • ST9100828SB • ST980815SB • ST960815SB • ...
Page 8 - About the Serial ATA interface; ers or other configuration options.
2 Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 1.1 About the Serial ATA interface The Serial ATA interface provides several advantages over the traditional (parallel) ATA interface. The primary advantages include: • Easy installation and configuration with true plug-and-play connectivity...
Page 9 - Specification summary table; Drive specifications
Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 3 2.0 Drive specifications Unless otherwise noted, all specifications are measured under ambient conditions, at 25°C, and nominal power. For convenience, the phrases the drive and this drive are used throughout this manual to indicate the ST91...
Page 11 - Formatted capacity; Default logical geometry; LBA mode; Model
Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 5 *One Gbyte equals one billion bytes when referring to hard drive capacity. Accessible capacity may vary depending on operating environment and formatting. **Typical notebooks will pull power to the drive when entering S3 and S4; while in the...
Page 12 - Drive model
6 Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 2.4 Physical organization 2.5 Recording and interface technology 2.6 Physical characteristics Drive model Read/write heads Number of discs ST9160821SB 4 2 ST9120822SB 3 2 ST9100828SB 3 2 ST980815SB 2 1 ST960815SB 2 1 ST9402116SB 1 1 Interfac...
Page 13 - Power consumption; Read; Average; Time to ready
Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 7 2.7 Seek time Seek measurements are taken with nominal power at 25°C ambient temperature. All times are measured using drive diagnostics. The specifications in the table below are defined as follows: • Track-to-track seek time is an average ...
Page 14 - Figure 1. Typical +5V startup and operation current profile; DC power; Power dissipation
8 Momentus 5400.3 SATA Blade Server Product Manual, Rev. E • Idle mode power Idle mode power is measured with the drive up to speed, with servo electronics active and with the heads in a random track location. • Standby mode During Standby mode, the drive accepts commands, but the drive is not spinn...
Page 15 - • SATA 1.0 design guides; Conducted noise
Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 9 2.9.2 Deferred spinup Momentus 5400.3 SATA drives provide a deferred spinup feature which storage subsystem controllers can use to sequence disc drive initialization. This is beneficial to systems which include multiple Serial ATA hard disc ...
Page 16 - Environmental specifications
10 Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 2.10 Environmental specifications 2.10.1 Ambient temperature Ambient temperature is defined as the temperature of the environment immediately surrounding the drive. Duty 50%, power-on hours (POH) of 8,750 per year (24 hours per day, 7 days ...
Page 18 - Acoustics; Electromagnetic immunity; Drive level acoustics
12 Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 2.11 Acoustics Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All mea-surements are consistent with ISO document 7779. Sound power measurements are taken under essentially free-field conditio...
Page 19 - Safety certification; Measurement type; Nonrecoverable read errors
Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 13 2.13 Reliability 2.14 Agency certification 2.14.1 Safety certification The drives are recognized in accordance with UL 1950 and CSA C22.2 (950) and meet all applicable sections of IEC950 and EN 60950 as tested by TUV North America. 2.14.2 E...
Page 20 - Korean RRL; • Trade name or applicant: Seagate Technology; FCC verification; • Reorient the receiving antenna.
14 Momentus 5400.3 SATA Blade Server Product Manual, Rev. E Korean RRL If these drives have the Korea Ministry of Information and Communication (MIC) logo, they comply with para-graph 1 of Article 11 of the Electromagnetic Compatibility control Regulation and meet the Electromagnetic Compatibility (...
Page 21 - Environmental protection; European Union Restriction of Hazardous Substances (RoHS); Corrosive environment
Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 15 2.15 Environmental protection Seagate designs its products to meet environmental protection requirements worldwide, including regulations restricting certain chemical substances. 2.15.1 European Union Restriction of Hazardous Substances (Ro...
Page 23 - Configuring and mounting the drive; Handling and static-discharge precautions; • Handle the drive only by its edges or frame.
Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 17 3.0 Configuring and mounting the drive This section contains the specifications and instructions for configuring and mounting the drive. 3.1 Handling and static-discharge precautions After unpacking, and before installation, the drive may b...
Page 24 - Configuring the drive; Figure 2. Serial ATA connectors; Serial ATA cables and connectors; Figure 3. Attaching SATA cabling; Each cable is keyed to ensure correct orientation.; Jumper block
18 Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 3.2 Configuring the drive Each drive on the Serial ATA interface connects in a point-to-point configuration with the Serial ATA host adapter. There is no master/slave relationship because each drive is considered a master in a point-to-poin...
Page 25 - Drive mounting; • Use only M3 UNC mounting screws.; Figure 4. Mounting dimensions—top, side and end view
Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 19 3.4 Drive mounting You can mount the drive using four screws in the side-mounting holes or four screws in the bottom-mounting holes. See Figure 4 for drive mounting dimensions. Follow these important mounting precautions when mount-ing the ...
Page 27 - Serial ATA connector pin definitions; Segment
Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 21 4.0 Serial ATA (SATA) interface These drives use the industry-standard Serial ATA interface that supports FIS data transfers. It supports ATA programmed input/output (PIO) modes 0–4; multiword DMA modes 0–2, and Ultra DMA modes 0–6. The dri...
Page 29 - Supported ATA commands; Command name
Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 23 4.3 Supported ATA commands The following table lists Serial ATA standard commands that the drive supports. For a detailed description of the ATA commands, refer to the Serial ATA: High Speed Serialized AT Attachment specification. See “S.M....
Page 32 - Identify Device command; The Identify Device command (command code EC; Word; xxxx
26 Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 4.3.1 Identify Device command The Identify Device command (command code EC H ) transfers information about the drive to the host following power up. The data is organized as a single 512-byte block of data, whose contents are shown in the t...
Page 34 - Bit
28 Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 93 Hardware reset value (see description following this table) xxxx H 94 Auto acoustic management setting xxxx H 95–99 ATA-reserved 0000 H 100–103 Total number of user-addressable LBA sectors available (see Section 2.2 for related informati...
Page 35 - Set Features command; Set Features command values
Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 29 4.3.2 Set Features command This command controls the implementation of various features that the drive supports. When the drive receives this command, it sets BSY, checks the contents of the Features register, clears BSY and generates an in...
Page 36 - Code in features register
30 Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 4.3.3 S.M.A.R.T. commands S.M.A.R.T. provides near-term failure prediction for disc drives. When S.M.A.R.T. is enabled, the drive moni-tors predetermined drive attributes that are susceptible to degradation over time. If self-monitoring det...
Page 37 - Seagate Technology support services; Internet; For information regarding Seagate products and services, visit; Seagate Service Centers; Presales Support; Seagate technical support is available to assist you online at
Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 31 5.0 Seagate Technology support services Internet For information regarding Seagate products and services, visit www.seagate.com . Worldwide support is available 24 hours daily by email for your questions. Presales Support: Presales@Seagate....
Page 38 - Customer Service Operations; Warranty Service; USA/Canada/Latin America support services; Direct dial; and Mexico; Europe, the Middle East and Africa Support Services
32 Momentus 5400.3 SATA Blade Server Product Manual, Rev. E Customer Service Operations Warranty Service Seagate offers worldwide customer support for Seagate products. Seagate distributors, OEMs and other direct customers should contact their Seagate Customer Service Operations (CSO) representative...
Page 39 - Index
Momentus 5400.3 SATA Blade Server Product Manual, Rev. E 33 Index A ACA 14 acoustics 4 , 12 Address 23 Agency certification 13 Altitude 10 Altitude, nonoperating 4 Altitude, operating 4 Ambient temperature 4 , 10 ambient temperature 7 Annualized Failure Rate (AFR) 4 Areal density 3 , 6 areal density...