Cheetah NS 10K.2 FC Product Manual, Rev. B i Contents 1.0 Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2.0 Standards, compliance and reference documents . . . . . . . . . . . . . . . . . . . . ...
ii Cheetah NS 10K.2 FC Product Manual, Rev. B 6.4.2 Relative humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 6.4.3 Effective altitude (sea level) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 6.4.4 Shock...
Cheetah NS 10K.2 FC Product Manual, Rev. B iii 9.5.12 Device control codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 9.6 Signal characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Cheetah NS 10K.2 FC Product Manual, Rev. B 1 1.0 Scope This manual describes Seagate Technology ® LLC, Cheetah NS 10K.2 FC (Fibre Channel) disk drives. Cheetah NS 10K.2 FC drives support the Fibre Channel Arbitrated Loop and SCSI Fibre Channel Protocol specifications to the extent described in this ...
Cheetah NS 10K.2 FC Product Manual, Rev. B 3 2.0 Standards, compliance and reference documents The drive has been developed as a system peripheral to the highest standards of design and construction. The drive depends upon its host equipment to provide adequate power and environment in order to achi...
4 Cheetah NS 10K.2 FC Product Manual, Rev. B 2.2 Compliance 2.2.1 Electromagnetic compliance Seagate uses an independent laboratory to confirm compliance with the directives/standards for CE Marking and C-Tick Marking. The drive was tested in a representative system for typical applications. The sel...
Cheetah NS 10K.2 FC Product Manual, Rev. B 5 2.3 Reference documents SCSI Commands Reference Manual Seagate part number: 100293068 Fibre Channel Interface Manual Seagate part number: 100293070 ANSI Fibre Channel Documents X3.230-1994 FC Physical and Signaling Interface (FC-PH) X3.297.1997 FC-PH-2 Fi...
Cheetah NS 10K.2 FC Product Manual, Rev. B 7 3.0 General description Cheetah NS 10K.2 FC drives provide high performance, high capacity data storage for a variety of systems including engineering workstations, network servers, mainframes, and supercomputers. Cheetah NS 10K.2 FCdrives support 4-Gbit ...
8 Cheetah NS 10K.2 FC Product Manual, Rev. B 3.1 Standard features Cheetah NS FC drives have the following standard features:• Perpendicular recording technology• 4-Gbit Fibre Channel interface• Integrated dual port FC-AL controller• Concurrent dual port transfers• Support for FC arbitrated loop, pr...
Cheetah NS 10K.2 FC Product Manual, Rev. B 9 3.3 Performance • Programmable multi-segmentable cache buffer • 800 Mbytes/sec maximum instantaneous data transfers per port• 10k RPM spindle. Average latency = 2.98 msec• Command queuing of up to 128 commands • Background processing of queue• Supports st...
10 Cheetah NS 10K.2 FC Product Manual, Rev. B 3.6 Programmable drive capacity Using the Mode Select command, the drive can change its capacity to something less than maximum. See the Mode Select Parameter List table in the SCSI Commands Reference Manual . Refer to the Parameter list block descriptor...
Cheetah NS 10K.2 FC Product Manual, Rev. B 11 4.0 Performance characteristics This section provides detailed information concerning performance-related characteristics and features of Cheetah NS 10K.2 FC drives. 4.1 Internal drive characteristics ST3600002FC ST3450802FC ST3300602FC Drive capacity* 6...
12 Cheetah NS 10K.2 FC Product Manual, Rev. B 4.2.2 Format command execution time (minutes) ST3600002FC ST3450802FC ST3300602FC Maximum (with verify) 182 129 83 Maximum (without verify) 101 68 43 Execution time measured from receipt of the last byte of the Command Descriptor Block (CDB) to the reque...
Cheetah NS 10K.2 FC Product Manual, Rev. B 13 4.4 Prefetch/multi-segmented cache control The drive provides a prefetch (read look-ahead) and multi-segmented cache control algorithms that in many cases can enhance system performance. Cache refers to the drive buffer storage space when it is used in c...
14 Cheetah NS 10K.2 FC Product Manual, Rev. B 4.5.1 Caching write data Write caching is a write operation by the drive that makes use of a drive buffer storage area where the data to be written to the medium is stored while the drive performs the Write command. If read caching is enabled (RCD=0), th...
Cheetah NS 10K.2 FC Product Manual, Rev. B 15 5.0 Reliability specifications The following reliability specifications assume correct host and drive operational interface, including all inter-face timings, power supply voltages, environmental requirements and drive mounting constraints. 5.1 Error rat...
16 Cheetah NS 10K.2 FC Product Manual, Rev. B 5.1.3 Seek errors A seek error is defined as a failure of the drive to position the heads to the addressed track. After detecting an initial seek error, the drive automatically performs an error recovery process. If the error recovery process fails, a se...
Cheetah NS 10K.2 FC Product Manual, Rev. B 17 The Pass-through state is disabled while the drive performs self test of the FC interface. The control line for an external port bypass circuit remains in the Enable Bypass state while self test is running. If the bypass circuit is present, loop operatio...
Cheetah NS 10K.2 FC Product Manual, Rev. B 19 be used to set this trip point. The default value for this drive is 68°C, however, you can set it to any value in the range of 0 to 68°C. If you specify a temperature greater than 68°C in this field, the temperature is rounded down to 68°C. A sense code ...
20 Cheetah NS 10K.2 FC Product Manual, Rev. B A Drive Not Ready condition is reported by the drive under the following conditions:• Motor will not spin• Motor will not lock to speed• Servo will not lock on track• Drive cannot read configuration tables from the disk In these conditions, the drive res...
Cheetah NS 10K.2 FC Product Manual, Rev. B 23 6.0 Physical/electrical specifications This section provides information relating to the physical and electrical characteristics of the drive. 6.1 AC power requirements None. 6.2 DC power requirements The voltage and current requirements for a single dri...
Cheetah NS 10K.2 FC Product Manual, Rev. B 25 Measured with average reading DC ammeter. Instantaneous +12V current peaks will exceed these values. Power supply at nominal voltage. N (number of drives tested) = 6, 35 Degrees C ambient.[4] For +12 V, a –10% tolerance is allowed during initial spindle ...
Cheetah NS 10K.2 FC Product Manual, Rev. B 29 6.3 Power dissipation ST3600002FC Typical power dissipation under idle conditions in 4 Gbit operation is 6.55 watts (22.33 BTUs per hour). To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure 4)....
32 Cheetah NS 10K.2 FC Product Manual, Rev. B 6.4 Environmental limits Temperature and humidity values experienced by the drive must be such that condensation does not occur on any drive part. Altitude and atmospheric pressure specifications are referenced to a standard day at 58.7°F (14.8°C). Maxim...
Cheetah NS 10K.2 FC Product Manual, Rev. B 33 6.4.3 Effective altitude (sea level) a. Operating –1,000 to +10,000 feet (–305 to +3,048 meters) b. Non-operating –1,000 to +40,000 feet (–305 to +12,192 meters) 6.4.4 Shock and vibration Shock and vibration limits specified in this document are measured...
Cheetah NS 10K.2 FC Product Manual, Rev. B 35 6.4.4.2 Vibration a. Operating—normal The drive as installed for normal operation, shall comply with the complete specified performance while subjected to continuous vibration not exceeding 10 - 300 Hz 1 G RMS (0 to peak) 301 - 500 Hz 0.5 G RMS (0 to pea...
Cheetah NS 10K.2 FC Product Manual, Rev. B 37 6.5 Mechanical specifications Refer to Figure 9 for detailed physical dimensions. See Section 8.4, “Drive mounting.” Figure 9. Mounting configuration dimensions Height (max): 1.013 in 25.73 mm Width (max): 3.999 in 101.57 mm Depth (max): 5.769 in 146.53 ...
Cheetah NS 10K.2 FC Product Manual, Rev. B 39 7.0 Defect and error management Seagate continues to use innovative technologies to manage defects and errors. These technologies are designed to increase data integrity, perform drive self-maintenance, and validate proper drive operation. SCSI defect an...
40 Cheetah NS 10K.2 FC Product Manual, Rev. B The drive firmware error recovery algorithms consists of 11 levels for read recoveries and five levels for write. Each level may consist of multiple steps, where a step is defined as a recovery function involving a single re-read or re-write attempt. The...
Cheetah NS 10K.2 FC Product Manual, Rev. B 41 7.3 FC-AL system errors Information on the reporting of operational errors or faults across the interface is given in the Fibre Channel Interface Manual . The FCP Response returns information to the host about numerous kinds of errors or faults. The Rece...
Cheetah NS 10K.2 FC Product Manual, Rev. B 43 8.0 Installation Cheetah NS 10K.2 FC disk drive installation is a plug-and-play process. There are no jumpers, switches, or terminators on the drive. Simply plug the drive into the host’s 40-pin Fibre Channel backpanel connector (FC-SCA) — no cables are ...
44 Cheetah NS 10K.2 FC Product Manual, Rev. B If forced air is necessary, possible air-flow patterns are shown in Figure 10. The air-flow patterns are created by fans either forcing or drawing air as shown in the illustrations. Conduction, convection, or other forced air-flow patterns are acceptable...
Cheetah NS 10K.2 FC Product Manual, Rev. B 45 8.5 Grounding Signal ground (PCBA) and HDA ground are connected together in the drive and cannot be separated by the user. The equipment in which the drive is mounted is connected directly to the HDA and PCBA with no electri-cally isolating shock mounts....
Cheetah NS 10K.2 FC Product Manual, Rev. B 47 9.0 Interface requirements This section partially describes the interface requirements as implemented on Cheetah NS 10K.2 FC drives. Additional information is provided in the Fibre Channel Interface Manual (part number 100293070). 9.1 FC-AL features This...
Cheetah NS 10K.2 FC Product Manual, Rev. B 49 9.1.4 Fibre Channel port login Table 9 identifies the required content of the N_Port Login (PLOGI) payload from an initiator. Table 9: N_Port login (PLOGI) payload Bytes 0-15 03 00 00 00 09 09 BB BB CF XX FS FS XX XX XX XX Common 16-31 XX XX XX XX PN PN ...
50 Cheetah NS 10K.2 FC Product Manual, Rev. B 9.1.5 Fibre Channel port login accept Table 10 identifies the N_Port Login access payload values. 9.1.6 Fibre Channel Process Login Table 11 lists the process login payload data. XX Indicates fields that are not used. Table 10: N_Port Login Accept (ACC) ...
Cheetah NS 10K.2 FC Product Manual, Rev. B 51 9.1.7 Fibre Channel Process Login Accept Table 12 lists Cheetah NS 10K.2 FC process login accept payload data. 9.1.8 Fibre Channel fabric login Table 13 lists the fabric login payload from the drive. Table 12: Process Login Accept (ACC) payload Bytes 0-1...
52 Cheetah NS 10K.2 FC Product Manual, Rev. B 9.1.9 Fibre Channel fabric accept login Table 14 lists the required content of the Fabric Login Accept (ACC) payload from the fabric. Table 14: Fabric Login Accept (ACC) payload Bytes 0-15 02 00 00 00 09 09 BB BB CF XX FS FS R_ A_ T0 V_ Common 16-31 E_ D...
Cheetah NS 10K.2 FC Product Manual, Rev. B 53 9.1.10 Fibre Channel Arbitrated Loop options Table 15 lists the FC-AL options supported by Cheetah NS 10K.2 FC drives. 9.2 Dual port support Cheetah NS 10K.2 FC drives have two independent FC-AL ports. These ports may be connected on indepen-dent loops o...
54 Cheetah NS 10K.2 FC Product Manual, Rev. B 9.3 SCSI commands supported Table 16 lists the SCSI commands supported by Cheetah NS 10K.2 FC drives. Table 16: Supported commands Command code Supported [4] Command name 00h Y Test unit ready 01h Y Rezero unit 03h Y Request sense Y Extended sense Y Fiel...
58 Cheetah NS 10K.2 FC Product Manual, Rev. B 9.3.1 Inquiry data Table 17 lists the Inquiry command data that the drive should return to the initiator per the format given in the Fibre Channel Interface Manual . * Copyright year (changes with actual year). ** SCSI Revision support. Refer to the appr...
Cheetah NS 10K.2 FC Product Manual, Rev. B 63 9.4 Miscellaneous operating features and conditions Table 21 lists various features and conditions. A “Y” in the support column indicates the feature or condition is supported. An “N” in the support column indicates the feature or condition is not suppor...
64 Cheetah NS 10K.2 FC Product Manual, Rev. B 9.5 FC-AL physical interface Figure 11 shows the location of the J1 Fibre Channel single connection attachment (FC-SCA). Figure 13 pro-vides the dimensions of the FC-SCA connector. Details of the physical, electrical, and logical characteristics are prov...
Cheetah NS 10K.2 FC Product Manual, Rev. B 65 9.5.2 Connector requirements The FC-AL SCA device connector is illustrated in Figure 13. Figure 13. FC-AL SCA device connector dimensions 9.5.3 Electrical description Fibre Channel drives use the FC-SCA connector for:• DC power• FC-AL interface• Drive se...
66 Cheetah NS 10K.2 FC Product Manual, Rev. B Table 23: FC-SCA pin descriptions Pin Signal name Signal type Pin Signal name Signal type 1* -EN bypass port A Low Voltage TTL output 21 12 Volts charge 2* 12 Volts 22 Ground 3* 12 Volts 23 Ground 4* 12 Volts 24* +Port A_in FC Diff. input pair 5* -Parall...
Cheetah NS 10K.2 FC Product Manual, Rev. B 69 9.5.11 SEL_6 through SEL_0 ID lines The SEL_6 through SEL_0 ID lines determine drive address, and, optionally, for an Enclosure Services Inter-face. When the Parallel ESI line is high, the enclosure backpanel must provide address information on the SEL l...
Cheetah NS 10K.2 FC Product Manual, Rev. B 71 9.5.12 Device control codes The drive inputs a Device Control Code on the DEV_CTRL_CODE lines at power up to determine the link rate on the Fibre Channel ports. Both ports run at the same rate. If the backpanel does not connect to these lines, the drive ...
72 Cheetah NS 10K.2 FC Product Manual, Rev. B 9.6.2 LED driver signals Fault and Active LED signals are located in the FC-SCA connector (J1). See Table 29 for the output character-istics of the LED drive signals. 9.6.3 FC Differential output The serial output signal voltage characteristics are provi...
Cheetah NS 10K.2 FC Product Manual, Rev. B 73 Figure 16 provides the data valid eye diagram for typical and minimum requirements to recover data at the specified interface error rate. The inputs are AC coupled on the drive. Figure 16. Receive eye diagram Table 32: Eye diagram data values Link rate 1...
Cheetah NS 10K.2 FC Product Manual, Rev. B 75 10.0 Seagate Technology support services Internet For information regarding Seagate products and services, visit www.seagate.com . Worldwide support is available 24 hours daily by email for your questions. Presales Support: [email protected] Technical...
76 Cheetah NS 10K.2 FC Product Manual, Rev. B Customer Service Operations Warranty Service Seagate offers worldwide customer support for Seagate products. Seagate distributors, OEMs and other direct customers should contact their Seagate Customer Service Operations (CSO) representative for warranty-...
Cheetah NS 10K.2 FC Product Manual, Rev. B 77 Index Numerics 12 volt pins 67 3rd party reserve command 57 5 volt pins 67 A Abort Sequence (ABTS) 47 abort task set function 48 AC coupling 66 AC power requirements 23 ACA active status 63 ACA active, faulted initiator status 63 Accept (ACC) 47 acoustic...
82 Cheetah NS 10K.2 FC Product Manual, Rev. B single-unit shipping pack kit 10 SMART 9 , 17 SMP = 1 in Mode Select command 63 SO 49 , 52 spindle brake 8 Stacked connection req. 49 , 52 standards 3 Start unit/stop unit command 55 start/stop time 12 support services 75 Supported diagnostics pages comm...
SEAGATE Manuals
-
SEAGATE ST9235AG
Manual
-
SEAGATE ST9250610NS
Manual
-
SEAGATE ST43401N/ND
Manual
-
SEAGATE STBM2000100
Manual
-
SEAGATE ST1000NM0033
Manual
-
SEAGATE ST34571N/W/WC/WD/DC
Manual
-
SEAGATE ST9250311CS
Manual
-
SEAGATE ST98823AS
Manual
-
SEAGATE ST9750420AS
Manual
-
SEAGATE ST1000NX0363
Manual
-
SEAGATE ST336752LW/LC
Manual
-
SEAGATE 100665905
Manual
-
SEAGATE ST5000VX0001
Manual
-
SEAGATE ST2000VN0001
Manual
-
SEAGATE ST600MP0094 - 512E
Manual
-
SEAGATE ST9300503SS
Manual
-
SEAGATE ST3300007FC/FCV
Manual
-
SEAGATE ST980313ASG
Manual
-
SEAGATE ST9120315ASG
Manual
-
SEAGATE ST500NM0001
Manual