SEAGATE ST3450802SS - Manuals
SEAGATE ST3450802SS – Manual in PDF format online.
Manuals:
Manual SEAGATE ST3450802SS
Summary
Copyright © 2009 Seagate Technology LLC. All rights reserved. Printed in U.S.A. Publication number: 100516228, Rev. C, November 2009 Seagate, Seagate Technology and the Wave logo are registered trademarks of Seagate Technology LLC in the United States and/or other countries. Cheetah, SeaTools and Se...
Cheetah NS 10K.2 SAS Product Manual, Rev. C i Contents 1.0 Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2.0 Standards, compliance and reference documents . . . . . . . . . . . . . . . . . . . ....
ii Cheetah NS 10K.2 SAS Product Manual, Rev. C 6.4.2 Relative humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 6.4.3 Effective altitude (sea level) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 6.4.4 Shoc...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 1 1.0 Scope This manual describes Seagate Technology ® LLC, Cheetah ® NS 10K.2 SAS (Serial Attached SCSI) disk drives. Cheetah drives support the SAS Protocol specifications to the extent described in this manual. The SAS Inter- face Manual (part number 10...
2 Cheetah NS 10K.2 SAS Product Manual, Rev. C 2.0 Standards, compliance and reference documents The drive has been developed as a system peripheral to the highest standards of design and construction. The drive depends on its host equipment to provide adequate power and environment for optimum perfo...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 3 2.2 Compliance 2.2.1 Electromagnetic compliance Seagate uses an independent laboratory to confirm compliance with the directives/standards for CE Marking and C-Tick Marking. The drive was tested in a representative system for typical applications. The se...
4 Cheetah NS 10K.2 SAS Product Manual, Rev. C 2.3 Reference documents SCSI Commands Reference Manual Seagate part number: 100293068 SAS Interface Manual Seagate part number: 100293071 Applicable ANSI SAS documents SFF-8323 3.5” Drive Form Factor with Serial Connector SFF-8460 HSS Backplane Design Gu...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 5 3.0 General description Cheetah ® NS 10K.2 SAS drives provide high performance, high capacity data storage for a variety of systems including engineering workstations, network servers, mainframes, and supercomputers. The Serial Attached SCSI interface is...
6 Cheetah NS 10K.2 SAS Product Manual, Rev. C 3.1 Standard features Cheetah NS SAS drives have the following standard features: • Perpendicular recording technology• 1.5 / 3 / 6 Gb Serial Attached SCSI (SAS) interface• Integrated dual port SAS controller• Support for SAS expanders and fanout adapter...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 7 3.5 Formatted capacities Standard OEM models are formatted to 512 bytes per block. The block size is selectable at format time and must be a multiple of 4 bytes. Users having the necessary equipment may modify the data block size before issuing a format ...
8 Cheetah NS 10K.2 SAS Product Manual, Rev. C 4.0 Performance characteristics This section provides detailed information concerning performance-related characteristics and features of Cheetah NS SAS drives. 4.1 Internal drive characteristics ST3600002SS ST3450802SS Drive capacity 600 450 GB (formatt...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 9 4.2.2 Format command execution time (minutes) ST3600002SS ST3450802SS Maximum (with verify) 182 129 Maximum (without verify) 101 68 Execution time measured from receipt of the last byte of the Command Descriptor Block (CDB) to the request for a Status By...
10 Cheetah NS 10K.2 SAS Product Manual, Rev. C 4.4 Prefetch/multi-segmented cache control The drive provides a prefetch (read look-ahead) and multi-segmented cache control algorithms that in many cases can enhance system performance. Cache refers to the drive buffer storage space when it is used in ...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 11 The buffer segmentation scheme is set up or changed independently, having nothing to do with the state of RCD. When a write command is issued, if RCD=0, the cache is first checked to see if any logical blocks that are to be written are already stored in...
12 Cheetah NS 10K.2 SAS Product Manual, Rev. C 5.0 Reliability specifications The following reliability specifications assume correct host and drive operational interface, including all inter-face timings, power supply voltages, environmental requirements and drive mounting constraints. 5.1 Error ra...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 13 a seek positioning error (Error code = 15h or 02h) will be reported with a Hardware error (04h) in the Sense Key. Recoverable seek errors are specified at Less than 10 errors in 10 8 seeks. Unrecoverable seek errors (Sense Key = 04h) are classified as d...
16 Cheetah NS 10K.2 SAS Product Manual, Rev. C The most thorough option is the extended test that performs various tests on the drive and scans every logical block address (LBA) of the drive. The short test is time-restricted and limited in length—it does not scan the entire media surface, but does ...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 17 Each test consists of three segments: an electrical test segment, a servo test segment, and a read/verify scan segment. Short test (Function Code: 001b) The purpose of the short test is to provide a time-limited test that tests as much of the drive as p...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 19 6.0 Physical/electrical specifications This section provides information relating to the physical and electrical characteristics of the drive. 6.1 AC power requirements None. 6.2 DC power requirements The voltage and current requirements for a single dr...
20 Cheetah NS 10K.2 SAS Product Manual, Rev. C transient response. [6] During idle, the drive heads are relocated every 60 seconds to a random location within the band from three-quarters to maximum track. Table 13: ST3450802SS DC power requirements Voltage +5V +12V [2] +5V +12V [2] +5V +12V [2] Reg...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 21 6.2.1 Conducted noise immunity Noise is specified as a periodic and random distribution of frequencies covering a band from DC to 10 MHz. Maximum allowed noise values given below are peak-to-peak measurements and apply at the drive power connector. 6.2....
Cheetah NS 10K.2 SAS Product Manual, Rev. C 23 6.3 Power dissipation ST3600002SS Typical power dissipation under idle conditions in 6Gb operation is 10.03W (34.23 BTUs per hour) To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure 3). Locate...
24 Cheetah NS 10K.2 SAS Product Manual, Rev. C 6.4 Environmental limits Temperature and humidity values experienced by the drive must be such that condensation does not occur on any drive part. Altitude and atmospheric pressure specifications are referenced to a standard day at 58.7°F (14.8°C). Maxi...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 25 6.4.2 Relative humidity The values below assume that no condensation on the drive occurs. a. Operating 5% to 95% non-condensing relative humidity with a maximum gradient of 20% per hour. b. Non-operating 5% to 95% non-condensing relative humidity. 6.4.3...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 27 6.4.4.2 Vibration a. Operating—normal The drive as installed for normal operation, shall comply with the complete specified performance while subjected to continuous vibration not exceeding 10 - 300 Hz 1.0 G RMS (0 to peak) 301 - 500 Hz 0.5 G RMS (0 to ...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 29 6.5 Mechanical specifications Refer to Figure 7 for detailed physical dimensions. See Section 8.3, “Drive mounting.” Figure 7. Physical dimensions Height: 1.013 in 25.73 mm Width: 3.999 in 101.57 mm Depth: 5.769 in 146.53 mm Weight: 1.482 lb 0.672 kg
30 Cheetah NS 10K.2 SAS Product Manual, Rev. C 7.0 Defect and error management Seagate continues to use innovative technologies to manage defects and errors. These technologies are designed to increase data integrity, perform drive self-maintenance, and validate proper drive operation. SCSI defect a...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 31 read or re-write attempt. The maximum level used by the drive in LBA recovery is determined by the read and write retry counts. Table 14 equates the read and write retry count with the maximum possible recovery time for read and write recovery of indivi...
32 Cheetah NS 10K.2 SAS Product Manual, Rev. C 7.3 SAS system errors Information on the reporting of operational errors or faults across the interface is given in the SAS Interface Manual . The SSP Response returns information to the host about numerous kinds of errors or faults. The Receive Diagnos...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 33 ations performed by the drive. When a write command is received for an LBA marked for DAR, the auto-reallo-cation process is invoked and attempts to rewrite the data to the original location. If a verification of this rewrite fails, the sector is re-map...
34 Cheetah NS 10K.2 SAS Product Manual, Rev. C 8.0 Installation Cheetah disk drive installation is a plug-and-play process. There are no jumpers, switches, or terminators on the drive. SAS drives are designed to be used in a host system that provides a SAS-compatible backplane with bays designed to ...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 35 8.2 Cooling The host enclosure must dissipate heat from the drive. You should confirm that the host enclosure is designed to ensure that the drive operates within the temperature measurement guidelines described in Section 6.4.1. In some cases, forced a...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 37 9.0 Interface requirements This section partially describes the interface requirements as implemented on Cheetah drives. Additional infor-mation is provided in the SAS Interface Manual (part number 100293071). 9.1 SAS features This section lists the SAS...
38 Cheetah NS 10K.2 SAS Product Manual, Rev. C 9.2 Dual port support Cheetah SAS drives have two independent ports. These ports may be connected in the same or different SCSI domains. Each drive port has a unique SAS address. The two ports run at the same link rate. The first port to successfully co...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 39 9.3 SCSI commands supported Table 17 lists the SCSI commands supported by Cheetah drives. Table 17: Commands supported by Cheetah ® NS 10K.2 SAS family drives Command name Command code Supported Change Definition 40h N Compare 39h N Copy 18h N Copy and ...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 43 9.3.1 Inquiry data Table 18 lists the Inquiry command data that the drive should return to the initiator per the format given in the SAS Interface Manual . Table 18: Inquiry data Bytes Data (hex) 0-15 00 00 xx** 12 8B 00 10 0A 53 45 41 47 41 54 45 20 Ve...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 45 9.3.2.1 ST3600002SS Mode Sense data HEADER DATA: 00 00 05 12 8B 00 10 02 MODE PAGES: DEF 80 06 00 80 0F 00 00 00 CHG 80 06 B7 C0 8F 00 00 00 DEF 81 0A C0 0B FF 00 00 00 05 00 FF FF CHG 81 0A FF FF 00 00 00 00 FF 00 FF FF DEF 82 0E 00 00 00 00 00 00 00 0...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 47 9.4 Miscellaneous operating features and conditions Table 19 lists various features and conditions. A “Y” in the support column indicates the feature or condition is supported. An “N” in the support column indicates the feature or condition is not suppo...
48 Cheetah NS 10K.2 SAS Product Manual, Rev. C 9.4.1 SAS physical interface Figure 10 shows the location of the SAS device connector J1. Figures 11 and 12 provide the dimensions of the SAS device. Details of the physical, electrical, and logical characteristics are provided within this section. The ...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 49 Figure 11. SAS connector dimensions C OF DATUM B L 5.08 1.27 (6X) 1.27 (14X) 15.875 0.35MIN 15.875 33.43 0.05 B 4.90 0.08 0.84 0.05 (22X) 0.15 B P15 P1 S7 S1 SEE Detail1 0.30 0.05 (4X) 4.00 0.08 0.15 D 0.30 0.05 (2X) 41.13 0.15 B B C C A A 0.20 B 42.73 ...
50 Cheetah NS 10K.2 SAS Product Manual, Rev. C Figure 12. SAS connector dimensions 9.4.2 Physical characteristics This section defines physical interface connector. 9.4.3 Connector requirements Contact your preferred connector manufacturer for mating part information. The SAS device connector is ill...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 51 9.4.4 Electrical description SAS drives use the device connector for: • DC power• SAS interface• Activity LED This connector is designed to either plug directly into a backpanel or accept cables. 9.4.5 Pin descriptions This section provides a pin-out of...
52 Cheetah NS 10K.2 SAS Product Manual, Rev. C 9.4.6 SAS transmitters and receivers A typical SAS differential copper transmitter and receiver pair is shown in Figure 13. The receiver is AC cou-pling to eliminate ground shift noise. Figure 13. SAS transmitters and receivers 9.4.7 Power The drive rec...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 53 The Ready LED Out signal is designed to pull down the cathode of an LED. The anode is attached to the proper +3.3 volt supply through an appropriate current limiting resistor. The LED and the current limiting resis-tor are external to the drive. See Tab...
54 Cheetah NS 10K.2 SAS Product Manual, Rev. C 9.5.2.1.2 Receive eye mask Figure 14 describes the receive eye mask. This eye mask applies to jitter after the application of a single pole high-pass frequency-weighting function that progressively attenuates jitter at 20 dB/decade below a frequency of ...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 55 The leading and trailing edge slopes of figure 14 shall be preserved. As a result the amplitude value of Z1 is less than that given in table 26 and Z1 TOL and Z1 OP shall be defined from those slopes by the following equa- tion: where: Z1 TOL is the val...
56 Cheetah NS 10K.2 SAS Product Manual, Rev. C 9.5.2.2 Transmitter signal characteristics Table 25 specifies the signal requirements at the transmitter end of a TxRx connection as measured into the zero-length test load. All specifications are based on differential measurements. The OOB sequence is ...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 57 9.5.2.3 Receiver signal characteristics Table 26 defines the compliance point requirements of the signal at the receiver end of a TxRx connection as measured into the test loads specified in figure 17 and figure 18. 9.5.2.3.1 Jitter Table 27 defines the...
58 Cheetah NS 10K.2 SAS Product Manual, Rev. C 9.5.2.3.2 Receiver jitter tolerance Table 28 defines the amount of jitter the receiver shall tolerate. 9.5.2.3.3 Compliant jitter test pattern (CJTPAT) The CJTPAT within a compliant protocol frame is used for all jitter testing unless otherwise specifie...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 59 9.5.2.4 Electrical TxRx connections TxRx connections may be divided into TxRx connection segments. In a single TxRx connection individual TxRx connection segments may be formed from differing media and materials, including traces on printed wir-ing boar...
62 Cheetah NS 10K.2 SAS Product Manual, Rev. C 9.5.2.5 Receiver characteristics The drive receiver is A.C. coupled. The receive network terminates the TxRx connection by a 100 ohm equiva-lent impedance as specified in table 29. The receiver operates within a BER of 10 -12 when a SAS signal with vali...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 63 10.0 Seagate Technology support services Internet For information regarding Seagate products and services, visit www.seagate.com . Worldwide support is available 24 hours daily by email for your questions. Presales Support: [email protected] Technica...
64 Cheetah NS 10K.2 SAS Product Manual, Rev. C Customer Service Operations Warranty Service Seagate offers worldwide customer support for Seagate products. Seagate distributors, OEMs and other direct customers should contact their Seagate Customer Service Operations (CSO) representative for warranty...
Cheetah NS 10K.2 SAS Product Manual, Rev. C 65 Index Numerics 12 volt pins 52 5 volt pins 52 6 Gbps 62 A abort task set function 37 AC coupling 52 AC power requirements 19 ACA active status 47 ACA active, faulted initiator status 47 acoustics 27 active LED Out signal 52 actuator assembly design 5 ad...
66 Cheetah NS 10K.2 SAS Product Manual, Rev. C environmental limits 24 requirements 12 environmental control 27 error management 30 rates 12 errors 30 EU RoHS directive 28 F FCC rules and regulations 2 features 6 interface 37 feed forward equalizer 62 FFE 62 firmware 6 corruption 42 flawed sector re...
68 Cheetah NS 10K.2 SAS Product Manual, Rev. C allowable for non-flat surface 36 switches 34 synchronized spindle operation 47 system chassis 36 T task management functions 37 Abort task set 37 Clear ACA 37 Clear task set 37 terminate task 37 task management response codes 37 Function complete 00 37...
SEAGATE Manuals
-
SEAGATE ST9235AG
Manual
-
SEAGATE ST9250610NS
Manual
-
SEAGATE ST43401N/ND
Manual
-
SEAGATE STBM2000100
Manual
-
SEAGATE ST1000NM0033
Manual
-
SEAGATE ST34571N/W/WC/WD/DC
Manual
-
SEAGATE ST9250311CS
Manual
-
SEAGATE ST98823AS
Manual
-
SEAGATE ST9750420AS
Manual
-
SEAGATE ST1000NX0363
Manual
-
SEAGATE ST336752LW/LC
Manual
-
SEAGATE 100665905
Manual
-
SEAGATE ST5000VX0001
Manual
-
SEAGATE ST2000VN0001
Manual
-
SEAGATE ST600MP0094 - 512E
Manual
-
SEAGATE ST9300503SS
Manual
-
SEAGATE ST3300007FC/FCV
Manual
-
SEAGATE ST980313ASG
Manual
-
SEAGATE ST9120315ASG
Manual
-
SEAGATE ST500NM0001
Manual