Page 4 - lue Terminal Position; Minimum Distances

F lue Terminal Position Dimen- sion Terminal Position Distance A Directly below an opening, air brick, opening windows, etc. 300mm B Above an opening, air brick , opening window, etc. 300mm C Horizontally to an opening, air brick , opening window, etc. 300mm D Below gutters, soil pipes or drain pipe...

Page 11 - Example of flue tube extension

Example of flue tube extension stop end Put grease on connecting O-rings.Use the same air inlet hose length as the length of the flue manifold. 21 22 Sleeve plate Terminal Body Concentric Port Connection Manifold Flue Tube of Unit Flue Tube of Unit Flue Tube of Unit stop end stop end

Page 13 - Purge air and sw arf f rom gas line.

W iring Diagram T esting the Unit 25 265 Purge air and sw arf f rom gas line. x Connect gas (1/2 inch BSP). Connection can be easilyreached from the top rear of the unit. x Check for escapes, using soapy water after turning gas on. x Remove fan filters. x Remove front covers, 2 screws at the bottom ...