37AHB Series Hydronic Furnace

The optimum in hydronic technology, the newly
designed Rinnai® multi-position hydronic furnaces
offer a unique solution for a wide variety of small- and
medium-sized residential and light commercial
applications. They are compact and ready to fit in tight
spaces which may include, but not limited to, attics,
basements, closets, crawlspaces, and utility rooms.

Intelligent Microprocessor Controller

The 37AHB units are equipped with an intelligent
microprocessor control that allows for domestic hot
water priority and adapts to available hot water flow for
space heating by automatically regulating the pump
and fan sequence to maximize comfort.

Fine Tuned to Work with Rinnai Tankless
Water Heaters

These unique hydronic furnaces are designed to work
in combination with our line of Rinnai® tankless water
heaters to deliver heating capacities that cover a wide
spectrum of residential and light commercial heating
applications. When combined, the units form the Rinnai
Tankless Heating System, the first matched, tankless
hydronic heating solution in the industry!

PATENT PENDING

FEATURES

Specifications

Air Delivery

Four models covering a range of heating capacities

27,100 to 96,300 BTU/hour

Multi-position (upflow, downflow, horizontal left,

horizontal right) without modifications *

Modifiable for side-entry return air

Low-flow, high-head pump custom designed to work

with Rinnai's tankless water heaters

Integrated control board with learning algorithm

No combustion air infiltration losses when used with

a Rinnai tankless water heater

Four selectable heat blower off delay times

Multi-speed motors (ECM)

Strong 20-gauge steel cabinet

Galvanized, painted

Fully insulated cabinet

Low 34 inch profile

Multi-position control box

Designed for serviceability

Schrader valves to purge air from the system

Integral filter rack with filter

Fan motor with ECM technology

*

NOTE: The unit is not designed to be installed on its back or

face down.

37AHB Series Hydronic Furnace

† Tested in accordance with ANSI/ASHRAE Standard 37-Latest edition.
‡ Airflows shown are nominal (blower speeds are factory set). For air
delivery other than stated, refer to the Air Delivery & Performance table.
†† Required filter sizes shown are based on the larger of the AHRI (Air
Conditioning & Refrigeration Institute) rated cooling airflow or the heating
airflow velocity of 300 ft/min for throwaway type or 450 ft/min for
high-capacity type.

Side intake filter to be (1) 20”x20”x1” typical for all models.
Air filter pressure drop for non-standard filters must not exceed 0.08 in. wg.
This product is manufactured in a facility registered by UL to ISO 9001.
File No. A6887.

Part of the Rinnai Tankless Heating System

AHB90

AHB75

AHB60

AHB45

600000060 (7/2010)

UL recogniz ed

component

This product is manufactured in a
facility registered by UL to ISO
9001.

37AHB Series Hydronic Furnace

0

0.1

0.

2

0.3

0.

4

0.5

0.

6

0.7

0.

8

0.9

1.

0

TA

P

3 (

H

)

2.

0

948

921

891

868

841

819

795

772

701

596

567

TA

P

4 (

M

)

2.

0

921

891

864

836

812

788

768

742

699

594

559

TA

P

5 (

L)

1.

5

803

768

740

712

682

652

628

596

569

541

510

TA

P

1 (

H

)

3.

0

1343

1318

1296

1270

1248

1225

1197

1168

1109

1025

889

TA

P

2 (

M

H

)

2.

5

1148

1128

1103

1072

1045

1012

984

955

937

908

690

TA

P

4 (

M

L)

2.

0

971

942

911

880

847

817

784

751

715

680

642

TA

P

5 (

L)

1.

5

844

810

777

734

698

665

626

581

533

504

466

TA

P

1 (

H

)

4.

0

1700

1666

1635

1604

1576

1543

1518

1492

1465

1430

1402

TA

P

2 (

M

H

)

3.

5

1561

1524

1490

1456

1428

1396

1364

1330

1230

1265

1224

TA

P

3 (

M

L)

3.

0

1391

1350

1320

1281

1245

1209

1190

1131

1090

1064

1031

TA

P

4 (

L)

2.

5

1222

1174

1140

1100

1063

1014

979

937

887

829

777

TAP 1

(

H

)

5.

0

1934

1889

1857

1818

1784

1750

1715

1680

1568

1491

1377

TA

P

2 (

M

H

)

4.

0

1777

1732

1694

1650

1630

1592

1553

1517

1464

1441

1361

TA

P

3 (

M

L)

3.

5

1573

1530

1490

1448

1417

1372

1327

1293

1253

1221

1175

TAP 4

(

L)

3.

0

1400

1351

1317

1275

1225

1183

1134

1095

1053

1011

951

37A

H

B

090 w

ith

RC

98

HP

, RC

80

H

P

,

R

94LS

, or

R

75LS

37A

H

B

060 w

ith

RC

98

HP

, RC

80

H

P

,

R

94LS

, R

75LS

, or

V

53i

AI

R

F

LO

W

(

C

FM

)

N

O

M

IN

A

L

A

IR DE

L

IV

E

RY

C

H

A

R

T

(

B

O

T

T

O

M

O

R

S

IDE

RE

T

URN w/

F

IL

T

E

R

)

Ex

te

rn

al

St

at

ic

Pr

es

su

re

(

ESP)

UNI

T S

IZ

E

ECM

SPEED

TA

P

SU

PPO

R

TS

CO

O

LI

N

G

CAP.

R

A

N

G

E

(T

O

N

S

)

37A

H

B

045 w

ith

RC

98

HP

, RC

80

H

P

,

R

94LS

, R

75LS

, or

V

53i

37A

H

B

075 w

ith

RC

98

HP

, RC

80

H

P

,

R

94LS

, or

R

75LS

C

M

Y

CM

MY

CY

CMY

K

37AHB spec sheet cover (7-2010).ai 7/23/2010 10:16:37 AM

37AHB spec sheet cover (7-2010).ai 7/23/2010 10:16:37 AM

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Rinnai Models