Page 2 - Before You Call; FOR YOUR RECORDS; Write the model and serial numbers here:; You can find them on a label on the appliance.; READ THIS MANUAL; DANGER; READ THE SAFETY INFORMATION
Care and Cleaning Draining . . . . . . . . . . . . . . . . 26Maintenance . . . . . . . . . . . . . 26Vent System Inspection . . . . 27Burner Inspection . . . . . . . . 27Extended Shut-Down . . . . . .28 Safety Information Safety Precautions . . . . . . . 3–6LP Gas Models . . . . . . . . . . . 5 Inst...
Page 3 - INSTALL THE BLOWER ASSEMBLY AND PROPERLY VENT; W A R N I N G; of this manual for a list of error codes.
Be sure to read and understand the entire Use and Care Manual before attempting to install or operate this water heater. It may save you time and money. Pay particular attention to the Safety Instructions. Failure to follow these warnings could result in serious bodily injury or death. Should you ha...
Page 4 - Time/Temperature Relationship in Scalds; WATER TEMPERATURE SETTING; IMPORTANT SAFETY INFORMATION.
Time/Temperature Relationship in Scalds Water Temperature Time To Produce a Serious Burn 120°F More than 5 minutes 125°F 1 1 / 2 to 2 minutes 130°F About 30 seconds 135°F About 10 seconds 140°F Less than 5 seconds 145°F Less than 3 seconds 150°F About 1 1 / 2 seconds 155°F About 1 second Table court...
Page 5 - DANGER: If a gas leak is present or; Do not
5 LP and Natural gas have an odorant added to aid in detecting a gas leak. Some people may not physically be able to smell or recognize this odorant. If you are unsure or unfamiliar with the smell of LP or natural gas, ask the gas supplier. Other conditions, such as “odorant fade”, which causes the ...
Page 6 - FOR INSTALLATIONS IN THE STATE OF CALIFORNIA; Do not; SAFETY PRECAUTIONS; SAVE THESE INSTRUCTIONS
6 IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. ! WARNING! For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life. FOR INSTALLATIONS IN THE STATE O...
Page 7 - Installing the water heater.; Location
Combustion Air Inlet Openings Installing the water heater. This water heater must be installed in accordance with these instructions, local codes, utility company requirements, and/or in the absence of local codes, use the latest edition of the American National Standard/National Fuel Gas Code. A co...
Page 8 - Combustion and Ventilation Air
8 Installing the water heater. Combustion and Ventilation Air Ventilation (ambient) air temperature must be 100°F or less. Proper operation of the water heater requires air for combustion and ventilation. Provisions for combustion and ventilation air must comply with referenced codes and standards.D...
Page 10 - Relief Valve
10 Installing the water heater. A new combination temperature and pressure relief valve, complying with the Standard for Relief Valves and Automatic Gas Shut-Off Devices for Hot Water Supply Systems, ANSI Z21.22, is supplied and must remain in the opening provided and marked for the purpose on the w...
Page 12 - Venting; Additional installation infor-
12 Installing the water heater. The water heater must be installed with the factory supplied blower assembly in place. Venting The water heater must be vented to the outdoors as described in these instructions. DO NOT connect this water heater to an existing vent or chimney - it must be vented separ...
Page 13 - Maximum Venting information for 3” Vents; Maximum Venting information for 4” Vents**; Maximum and Minimum Vent Lengths for Residential
Installing the water heater. Number of 90° elbows with Vent Number of 45° Elbows Maximum Vent Pipe Length in Feet (ft) 0’ - 2,000’ Maximum Vent Pipe Length in Feet (ft) 2,001’ and above. See Maximum Altitude chart on left. One (1) None 45 35 One (1) One (1) 42.5 32.5 Two (2) None 40 30 Two (2) One (...
Page 15 - A 90° vent termination must be used and must be at least
15 NOTICE: All pipe, fittings, solvent cement, primers and procedures must conform to American National Standards Institute and American Society for Testing and Materials (ANSI/ASTM) standards. Vertical Vent Installation Once the vent terminal location has been determined, make a hole through the ro...
Page 16 - Cementing Joints
16 Installing the water heater. All joints in the vent piping must be properly sealed and the following materials are recommended:PVC materials should use ASTM D2564 grade cement.CPVC materials should use ASTM F493 grade cement.ABS materials should use ASTM D2235 grade cement. Cleaner-Primer and Med...
Page 17 - Wiring; dangerous operation. VERIFY PROPER OPERATION AFTER SERVICING!; SCHEMATIC
17 Wiring If local codes permit, the water heater may be connected to electric service with the power cord provided (DO NOT use an extension cord). A grounding receptacle is required.If local codes do not permit the use of cord connections, a 120 V, 50/60 Hz power supply, with suitable disconnecting...
Page 18 - Hot and Cold Pipe Insulation Installation
For increased energy efficiency, some water heaters have been supplied with two 24” sections of pipe insulation. Please install the insulation, according to the illustrations above, that best meets your requirements. Typical vertical piping arrangement Typical horizontal piping arrangement Hot and C...
Page 19 - Heat Trap
DO ❑ DO check inlet gas pressure to ensure that it is within the range specified on the rating plate. ❑ DO provide adequate air for combustion and ventilation as discussed in the Use and Care Manual and the National Fuel Gas Code. ❑ DO maintain proper clearances to combustibles as specified on the r...
Page 20 - Installation Checklist; A. Water Heater Location
Installation Checklist A. Water Heater Location B. Water Supply C. Gas Supply D. Relief Valve E. Venting ❑ Close to area of vent. ❑ Indoors and protected from freezing temperatures. ❑ Proper clearance from combustible surfaces observed and water heater not installed on carpeted floor. ❑ Sufficient f...
Page 21 - in this manual and take precedent over these instructions.; Combination Potable Water and Space Heating Application; Tee fitting must be installed as shown.; water heater to fan coil (developed length)
Tee fitting for vertical hot water supply lines. Hot water supply to house From HOT outlet on water heater Hot water supply to heating unit Supplemental instructions for gas water heaters installed in potable water/space heating applications. Local codes or plumbing authority requirements may vary f...
Page 22 - Lighting the water heater.; STOP, and get help from a qualified person.; FOR YOUR SAFETY READ BEFORE OPERATING
22 Lighting the water heater. Before operating this water heater, be sure to read and follow the instructions on the label pictured below and all other labels on the water heater, as well as the warnings printed in this manual. Failure to do so can result in unsafe operation of the water heater resu...
Page 23 - Safety Precautions; Operating the water heater.; Water Temperature Setting
Safety Precautions Do turn off manual gas shut-off valve if water heater has been subjected to over heating, fire, flood, physical damage or if the gas supply fails to shut off. Do Not turn on water heater unless it is completely filled with water. Do Not turn on water heater if cold water supply sh...
Page 24 - Water Temperature Setting...
24 Operating the water heater. Water Temperature Setting… Maximum water temperatures occur just after the burner has shut off. To determine the water temperature, turn on a hot water faucet and place a thermometer in the water stream.To avoid any unintentional changes in water temperature settings, ...
Page 25 - Sequence of Operation...
25 Sequence of Operation… During initial start-up or a call for heat, the control will verify the vacuum switch is open.Once the control verifies the blower vacuum switch is open, the control will energize the blower motor for the pre-purge sequence (approximately 5 seconds).The control will verify ...
Page 26 - Care and cleaning of the water heater.; Draining the Water Heater
26 Care and cleaning of the water heater. Draining the Water Heater ! CAUTION: Shut off gas to the water heater at the gas control (thermostat) gas cock or manual shut-off valve before draining water. ! DANGER: Before manually operating the temperature and pressure relief valve, make certain no one ...
Page 28 - Care and cleaning of the water heater
28 Vacation and Extended Shut-Down If the water heater is to remain idle for an extended period of time, the power and water to the appliance should be turned off to conserve energy and prevent a build-up of dangerous hydrogen gas.The water heater and piping should be drained if they might be subjec...
Page 29 - Before You Call For Service...; Problem
29 Before You Call For Service… Troubleshooting TipsSave time and money! Review the charts on the following pages first and you may not need to call for service. This water heater incorporates a combustion shut off device that shuts the operation of the water heater down if undesirable combustion co...
Page 31 - Gas Valve LED Codes; FV sensor detected presence of flammable vapors.
Gas Valve LED Codes 31 CAUTION: Make certain power to water heater is “OFF” before removing protective cover FOR ANY REASON. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. VERIFY PROPER OPERATION AFTER SERVICING. CAU...
Page 32 - For 75 gallon models using natural or LP gas.; Instructions For Placing a Parts Order; NOT attempt repair of gas piping,
32 Replacement Parts. For 75 gallon models using natural or LP gas. Instructions For Placing a Parts Order All parts orders should include: The model and serial number of the water heater from the rating plate. Specify type of gas (natural or LP) as marked on the rating plate. Part description (as n...
Page 36 - IF YOU NEED SERVICE; Service Department at the following address:; Important Instructions for the Commonwealth of Massachusetts
36 IF YOU NEED SERVICE 1. Should you have any questions about your new water heater, or if it requires adjustment, repair, or routine maintenance, it is suggested that you first contact your installer, plumbing contractor or previously agreed upon service agency. In the event the firm has moved, or ...