Rheem 900 BTU Max input- Manual

Rheem 900 BTU Max input

Rheem 900 BTU Max input– Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
Page: / 28

Table of Contents:

  • Page 2 – Write the model and serial numbers here:; DANGER; READ THE SAFETY INFORMATION
  • Page 3 – PROPERLY INSTALL WATER HEATER...
  • Page 5 – camouflage a gas leak.; NATURAL GAS AND LIQUEFIED PETROLEUM MODELS; Notice: If a gas leak is present or suspected:; attempt to find the cause yourself.; Do not; try to light any appliance.; Do not; touch any electrical switch.; Do not; use any phone in your building.
  • Page 6 – SAFETY PRECAUTIONS; IMPORTANT SAFETY INFORMATION.; FOR INSTALLATIONS IN THE STATE OF CALIFORNIA; SAVE THESE INSTRUCTIONS
  • Page 7 – Installing the water heater.; Location
  • Page 8 – Combustion and Ventilation Air; NOTICE: The water heater; Inspect Shipment
  • Page 9 – Use approved plumbing materials only.
  • Page 10 – Relief Valve
  • Page 11 – an open flame to test for
  • Page 12 – Flue Terminal Location
  • Page 13 – Remote Control Installation
  • Page 15 – Electrical Connection; WIRING DIAGRAM
  • Page 16 – Typical Installation
  • Page 18 – A Water Heater Location; Installation Check List
  • Page 19 – Lighting the water heater.; and get help from a qualified person.
  • Page 20 – Time/Temperature Relationship in Scalds; Water Temperature Setting; turn off manual gas shut-off valve if water heater
  • Page 21 – Water Temperature Setting...; The factory setting allows; The water heater may not operate
  • Page 22 – Care and cleaning of the water heater.; Routine Preventative Maintenance
  • Page 23 – Burner Inspection; Vacation and Extended Shut-Down; DO NOT
  • Page 25 – Before You Call For Service...; Problem
  • Page 26 – Error Code Guide; Error Code; What To Do; Notice
  • Page 28 – IF YOU NEED SERVICE; to the front panel of the heater.
Loading the manual

AP13592 (06/04)

FOR YOUR SAFETY!

Do not store or use gasoline or other
flammable vapors or liquids or other
combustible materials in the vicinity of this or
any other appliance. To do so may result in an
explosion or fire.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not
use any phone in your building.

Immediately call your gas supplier from a
neighbor’s phone. Follow the gas
supplier’s instructions.

If you cannot reach your gas supplier, call
the fire department.

Do not return to your home until authorized
by the gas supplier or fire department.

Improper installation, adjustment,
alteration, service or maintenance can cause
property damage, personal injury, or death.
Refer to this manual. Installation and service
must be performed by a qualified installer,
service agency or the gas supplier.

!

WARNING: If the information in these instructions is not followed exactly,

a fire or explosion may result causing property damage, personal injury or death.

!

The purpose of this manual is twofold: one, to provide the installer with
the basic directions and recommendations for the proper installation and
adjustment of the water heater; and two, to the owner–operator, to
explain the features, operation, safety precautions, maintenance and
troubleshooting of the water heater. This manual also includes a parts
list.

It is imperative that all persons who are expected to install, operate or
adjust this water heater read the instructions carefully so they may
understand how to perform these operations. If you don’t understand
these instructions or any terms within it, seek professional advice.

Any questions regarding the operation, maintenance, service or
warranty of this water heater should be directed to the seller from whom
it was purchased. If additional information is required, refer to the
section on If You Need Service.

Do not destroy this manual. Please read carefully and keep in a safe
place for future reference.

Recognize this symbol as an indication of Important Safety
Information!

California Proposition 65 Warning: This product contains
chemicals known to the State of California to cause cancer, birth
defects or other reproductive harm.

!

!

Use & Care Manual

With Installation Instructions for the Installer

Printed in Japan

Tankless

Water Heater

DESIGN

CERTIFIED

®

Warning: This water heater is not suitable

for use in manufactured (mobile) homes!

!

31-51482

Residential Outdoor Gas

199,900 BTU Max Input

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Rheem 900 BTU Max input

Summary

Page 2 - Write the model and serial numbers here:; DANGER; READ THE SAFETY INFORMATION

Safety Information Safety Precautions . . . . . . . 3–6 LP Gas Models . . . . . . . . . . . 5 Installation Instructions Location . . . . . . . . . . . . . . . . . 7 Water Connections. . . . . . 9-10 Gas Supply . . . . . . . . . . . . . . 11 High Altitude . . . . . . . . . . . . 11 Venting . . . . . ...

Page 3 - PROPERLY INSTALL WATER HEATER...

Be sure to read and understand the entire Use and Care Manual before attempting to install or operatethis water heater. It may save you time and money. Pay particular attention to the Safety Instructions.Failure to follow these warnings could result in serious bodily injury or death. Should you have...

Page 5 - camouflage a gas leak.; NATURAL GAS AND LIQUEFIED PETROLEUM MODELS; Notice: If a gas leak is present or suspected:; attempt to find the cause yourself.; Do not; try to light any appliance.; Do not; touch any electrical switch.; Do not; use any phone in your building.

5 Both LP and natural gas have an odorant added to aid in detecting a gas leak. Some people may not physically be able to smell or recognize this odorant. If you are unsure or unfamiliar with the smell of LP or natural gas, ask the gas supplier. Other conditions, such as “odorant fade”, which causes...

Other Rheem Models