Page 2 - PATENTS; in the name of Rheem Australia Pty Ltd.; TRADEMARKS; Registered trademark of Rheem Australia Pty Ltd.; Trademark of Rheem Australia Pty Ltd.
PATENTS This water heater may be protected by one or more patents or registered designs in the name of Rheem Australia Pty Ltd. TRADEMARKS ® Registered trademark of Rheem Australia Pty Ltd. TM Trademark of Rheem Australia Pty Ltd. Note: Every care has been taken to ensure the accuracy in preparation...
Page 3 - CONTENTS; HOUSEHOLDER - We recommend you read pages 4 to 17.
CONTENTS About Your Water Heater ......................................................... .. .. 4 Regular Care ......................................................................... .. ....... 9 Water Supplies ........................................................................... 11 Save A ...
Page 4 - ABOUT YOUR WATER HEATER; MODEL TYPE; “Single Element Model”; MAINS PRESSURE; “Temperature Adjustment”
4 ABOUT YOUR WATER HEATER MODEL TYPE The Rheem ® water heater you have chosen is an Optima™ m odel. The Optima model has a temperature adjusting knob on the lower front of the water heater. Optima models are available with either a single heating unitor with twin heating units. (refer to “Single Ele...
Page 5 - HOTTER WATER INCREASES THE RISK OF SCALD INJURY
ABOUT YOUR WATER HEATER 5 HOTTER WATER INCREASES THE RISK OF SCALD INJURY This water heater can deliver water at temperatures which can cause scalding. Check the water temperature before use, such as when entering a shower or filling a bath or basin, to ensure it is suitable for the application and ...
Page 6 - WARNING; wner‟
ABOUT YOUR WATER HEATER 6 WARNING This water heater is only intended to be operated by persons who have the experience or the knowledge and the capabilities to do so. This water heater is not intended to be operated by persons with reduced physical, sensory or mental capabilities i.e. the infirm, or...
Page 8 - you must read page; described on
ABOUT YOUR WATER HEATER 8 TO TURN OFF THE WATER HEATER If you plan to be away from home for only a few nights, we suggest you leave the water heater switched on. If it is necessary to turn off the water heater: Switch off the electrical supply at the isolating switch to the water heater. Unplug the ...
Page 9 - REGULAR CARE; TEMPERATURE PRESSURE RELIEF VALVE; “Temperature Pressure Relief Valve; It is very important; m S
9 REGULAR CARE TEMPERATURE PRESSURE RELIEF VALVE This valve is near the top of the water heater and is essential for its safe operation. It is possible for the valve to release a little water through the drain line during each heating period. This occurs as the water is heated and expands by approxi...
Page 10 - TEMPERATURE LIMITING VALVE; “Water Supplies”; EXPANSION CONTROL VALVE; relief valve on the water heater.; It is very important you raise and lower the lever gently.; The
REGULAR CARE 10 TEMPERATURE LIMITING VALVE The valve should be checked for performance every twelve months. This can be performed by measuring the water temperature from a hot tap with a thermometer. If the water is being delivered at a temperature exceeding 55°C, phone a Rheem Service Centre. The v...
Page 11 - WATER SUPPLIES; covered by the warranty.; Anode Selection chart
11 WATER SUPPLIES This water heater must be installed in accordance with this advice to be covered by the warranty. This water heater is manufactured to suit the water conditions of most public reticulated water supplies. However, there are some known water chemistries which can have detrimental eff...
Page 12 - ANODE INSPECTION; Optima; CAUTION; of the water heater during long periods of no use.
WATER SUPPLIES 12 CONDUCTIVITY - µS/cm TOTAL DISSOLVED SOLIDS & CONDUCTIVITY (vitreous enamel lined water heater cylinder) 40 150 400 600 TOTAL DISSOLVED SOLIDS (TDS) - mg/L ANODE SELECTION warranty applies to a vitreous enamel lined water heater cylinder if the correct coloured anode is used fo...
Page 13 - water‟
WATER SUPPLIES 13 SATURATION INDEX The saturation index is used as a measure of the water‟ s corrosive or scaling properties. In a corrosive water supply, the water can attack copper parts and cause them to fail. Where the saturation index is less than –1.0, the water is very corrosive and warranty ...
Page 14 - CHANGE OF WATER SUPPLY
WATER SUPPLIES 14 CHANGE OF WATER SUPPLY The changing or alternating from one water supply to another can have a detrimental effect on the operation and / or life expectation of a water heater cylinder, a temperature pressure relief valve and a heating unit. Where there is a changeover from one wate...
Page 15 - SAVE A SERVICE CALL; “Off-Peak Electricity Supply”
15 SAVE A SERVICE CALL Check the items below before making a service call. You will be charged for attending to any condition or fault that is not related to the manufacture or failure of a part. NOT ENOUGH HOT WATER (OR NO HOT WATER) Is the electricity switched on? Inspect the isolating switch mark...
Page 16 - “Temperature Pressure Relief Valve”
SAVE A SERVICE CALL 16 Water heater size Do you have the correct size water heater for your requirements? The sizing guide in the Rheem sales literature and on the Rheem website (www.rheem.co.nz) suggests average sizes that may be needed. TEMPERATURE PRESSURE RELIEF VALVE RUNNING Normal Operation It...
Page 17 - EXPANSION CONTROL VALVE RUNNING
SAVE A SERVICE CALL 17 EXPANSION CONTROL VALVE RUNNING If an expansion control valve is fitted in the cold water line to the water heater (refer to page 27 ) it may discharge a small quantity of water instead of the temperature pressure relief valve on the water heater. The benefit is that energy is...
Page 18 - INSTALLATION; THIS WATER HEATER IS NOT SUITABLE FOR POOL HEATING
18 INSTALLATION THIS WATER HEATER IS NOT SUITABLE FOR POOL HEATING The installation must comply with the requirements of AS/NZS 3500.4, AS/NZS 3000 and all local codes and regulatory authority requirements. In New Zealand, the installation must conform with the New Zealand Building Code. All packagi...
Page 19 - SAFE TRAY; (refer to diagram on page; Model; TANK WATER SUPPLY
INSTALLATION 19 Remember all local authorities have regulations about putting water heaters into roof spaces. SAFE TRAY It is a requirement of AS/NZS 3500.4 that for a new installation, a water heater be installed in a safe tray where in the event of a leak, property may otherwise be damaged. Constr...
Page 20 - Feet for Rheem Externally Mounted Cylinders; Feet are 50mm in from edge of cylinder
INSTALLATION Feet for Rheem Externally Mounted Cylinders Optima 180, 300 and 400L Mains Pressure Water Heaters (3 pieces) Outside diameters 180 model – 488mm 300 model – 580mm 400 model – 690mm Feet are 50mm in from edge of cylinder Installation options: 1. Push tags into soft concrete at correct po...
Page 21 - HOT WATER DELIVERY; bathroom, ensuite or other ablution area.; Two Temperature Zones Using a Temperature Limiting Device
INSTALLATION 2 1 HOT WATER DELIVERY This water heater can deliver water at temperatures which can cause scalding. It is necessary and we recommend that a temperature limiting device be fitted between a Rheemglas or Optima water heater and the hot water outlets in any ablution area such as a bathroom...
Page 22 - CIRCULATED HOT WATER FLOW AND RETURN SYSTEM; diagram on page; Temperature Limiting Device
INSTALLATION 2 2 CIRCULATED HOT WATER FLOW AND RETURN SYSTEM If a Rheem water heater is to be installed as part of a circulated hot water flow and return system, a storage water heater able to provide a hot water outlet temperature of at least 60°C must be used. Note: The thermostat must always be a...
Page 23 - Circulated Hot Water Flow and Return; will be significantly reduced.; REDUCING HEAT LOSSES; to the heat loss that occurs through the pipework.
INSTALLATION 2 3 Circulated Hot Water Flow and Return Continuous Electric Water Heater Off-Peak or Time Controlled Electricity Supply A single or twin element electric water heater connected to an Off-Peak electricity supply should not be installed as part of a circulated hot water flow and return s...
Page 24 - ANODE
INSTALLATION 2 4 ANODE The vitreous enamel lined cylinder of the water heater is only covered by warranty when the total dissolved solids (TDS) content in the water is less than 2500 mg/L and when the correct colour coded anode is installed. The use of an incorrect colour coded anode will void the c...
Page 25 - DIMENSIONS AND TECHNICAL DATA
INSTALLATION 2 5 DIMENSIONS AND TECHNICAL DATA Optima Single Element Optima Twin Element 913 180 - - - 913 300 9 13 40 0 Hot Water Delivery Litres 18 0 3 0 0 400 Boost Capacity Litres - 50 90 Dimensions A mm 1 720 1 825 1840 B mm 488 580 690 C mm 554 646 755 D mm 1 482 1 569 1479 E mm 7 4 74 121 F m...
Page 26 - TYPICAL INSTALLATION – OUTDOOR LOCATION; IN; Seismic strapping
INSTALLATION 26 TYPICAL INSTALLATION – OUTDOOR LOCATION TYPICAL INSTALLATION – INDOOR LOCATION OUTDOOR LOCATIONS IN DOOR LOCATIONS Seismic strapping must conform with G12 NZ Building Code Plastic feet supplied must be fitted to base of cylinder.
Page 27 - CONNECTIONS – PLUMBING; CONNECTION SIZES; “Hot
2 7 CONNECTIONS – PLUMBING CONNECTION SIZES Optima Hot water connection: RP ¾/20 Cold water connection: RP ¾/20 Relief valve connection: RP ½/15 All plumbing work must be carried out by a qualified person and in accordance with the Plumbing Standard AS/NZS 3500.4 and local authority requirements. WA...
Page 28 - PIPE SIZES; (refer to the installation diagram on; (refer to diagram on
CONNECTIONS – PLUMBING 2 8 PIPE SIZES To achieve true mains pressure operation, the cold water line to the water heater should be the same size or bigger than the hot water line from the water heater. The pipe sizing for hot water supply systems should be carried out by persons competent to do so, c...
Page 29 - RELIEF VALVE DRAIN; A drain line must be comply with AS/NZS 3500 or G12 NZ Building code.
CONNECTIONS – PLUMBING 2 9 RELIEF VALVE DRAIN DN15 copper drain lines must be fitted to the temperature pressure relief valve and expansion control valve (if one is installed) to carry the discharge clear of the water heater. Connect the drain lines to the valves using disconnection unions. The drai...
Page 30 - CONNECTIONS – ELECTRICAL; water heater is filled with water; twin element model; THERMOSTAT SETTING
30 CONNECTIONS – ELECTRICAL The power supply to the water heater must not be switched on until the water heater is filled with water and a satisfactory megger reading is obtained. All electrical work and permanent wiring must be carried out by a qualified person and in accordance with the Wiring Rul...
Page 31 - ASSEMBLY OF ADJUSTER MECHANISM ON OPTIMA MODEL
CONNECTIONS – ELECTRICAL 31 For reasons of safety and economy, we advise the thermostat be set at the lowest temperature that will provide sufficient hot water. Dishwasher running costs can be adversely affected if the thermostat is set below 65°C. Discuss the thermostat setting requirements with th...
Page 32 - WIRING DIAGRAM TWIN ELEMENT ELECTRIC WATER HEATERS; connected to the bottom heating unit circuit.
CONNECTIONS – ELECTRICAL 3 2 WIRING DIAGRAM TWIN ELEMENT ELECTRIC WATER HEATERS NON-SIMULTANEOUS OPERATION OFF-PEAK CONNECTION Electrical Circuit for Twin Element Models – Robertshaw “ST” Thermostats The active from the continuous supply must be connected to the top heating unit circuit and the acti...
Page 33 - COMMISSIONING; TO FILL AND TURN ON THE WATER HEATER; and a satisfactory megger reading is; TO TURN OFF THE WATER HEATER; such as on a building site or where the premises is vacant, then
3 3 COMMISSIONING TO FILL AND TURN ON THE WATER HEATER The power supply to the water heater must not be switched on until the water heater is filled with water and a satisfactory megger reading is obtained. Open all of the hot water taps in the hous e (don‟ t forget the shower). Open the cold water ...
Page 34 - DRAINING THE WATER HEATER; To drain the water heater:
3 4 DRAINING THE WATER HEATER To drain the water heater: Turn off the water heater (refer to “To Turn Off The Water Heater” on page 3 3 ). Close all hot water taps. Operate the relief valve release lever - do not let the lever snap back or you will damage the valve seat. Operating the lever will rel...
Page 35 - WARRANTY CONDITIONS; WARRANTY EXCLUSIONS
3 5 RHEEM ELECTRIC DOMESTIC MAINS PRESSURE WATER HEATER WARRANTY WARRANTY CONDITIONS 1. This warranty is applicable only to water heaters manufactured from 1 st Oct 2010. 2. The water heater must be installed in accordance with the water heater installation instructions, supplied with the water heat...
Page 36 - WARRANTY
RHEEM ELECTRIC DOMESTIC MAINS PRESSURE WATER HEATER WARRANTY WARRANTY In addition to your legal rights, Rheem New Zealand makes the following promise to the customer. We will repair, or if necessary, replace a defective domestic water heater, or part, which has failed due to faulty manufacture on th...