Page 2 - TABLE OF CONTENTS
Air Table of Contents R801S (UF/HZ) Series 2 TABLE OF CONTENTS Standard & Optional Equipment ......................................................................3 Model Features/Physical Data & Specifications..................................................4 Model Number Identification .....
Page 3 - WARNING; THIS FURNACE IS NOT APPROVED; STANDARD EQUIPMENT
Air Standard & Optional Equipment R801S (UF/HZ) Series 3 WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES DIRECT SPARK IGNITOR IN-SHOT BURNERS DRAFT INDUCER MOTOR PATENTED HEAT EXCHANGER INTEGRATED FURNACE CONTROL STANDARD EQUIPMENT Completely assembled and wired; indu...
Page 4 - Model Features
Air Model Features/Physical Data & Specifications R801S (UF/HZ) Series 4 MODEL NUMBERS R801S SERIES R801SA050314M*A R801SA075417M*A R801SA100521M*A R801SA125524M*A R801SA150524M*A Input-BTU/Hr [kW] ➁ 50,000 [15] 75,000 [22] 100,000 [29] 125,000 [37] 150,000 [44] Heating Capacity BTU/Hr [kW] ➀ 40...
Page 5 - Model Number Identification
R 80 1 S A 075 4 17 M S A Rheem 80 = 80% AFUE 1 = Single Stage S = PSC Standard Design Series A = 1st Design Input BTU/HR [kW] 050 = 50,000 [15]075 = 75,000 [22]100 = 100,000 [29]125 = 125,000 [37]150 = 150,000 [44] 3 = Up to 3 Ton 4 = Up to 4 Ton 5 = Up to 5 Ton Cabinet Width 14 = 14" .0 17 = 1...
Page 6 - Upflow Application
Air Dimensional Data R801S (UF/HZ) Series 6 Upflow Application MODELR801S- A B C D E F REDUCED CLEARANCE (IN.) [mm] SHIP WGTS. (LBS.) [kg] LEFT SIDE RIGHT SIDE BACK TOP FRONT VENT 050 14 1 / 2 [356] 12 27 / 32 [326] 10 5 / 8 [270] ➀ 11 1 / 2 [292] 1 7 / 8 [48] 0 4 [102] ➁ 0 1 [25] 3 [76] 6 [152] ➂ 8...
Page 7 - Dimensional Data: Horizontal Model
Air Dimensional Data R801S (UF/HZ) Series 7 MODELR801S- A B C D E F REDUCED CLEARANCE (IN.) [mm] SHIP WGTS. (LBS.) [kg] LEFT SIDE RIGHT SIDE BACK TOP FRONT VENT 050 14 1 / 2 [356] 12 27 / 32 [326] 10 5 / 8 [270] ➀ 11 1 / 2 [292] 1 7 / 8 [48] 0 4 [102] ➁ 0 1 [25] 3 [76] 6 [152] ➂ 85 [38.6] 075 17 1 /...
Page 8 - Blower Performance Data
Air Blower Performance Data R801S (UF/HZ) Series 8 MODEL MOTOR H.P. [W] BLOWER SIZE IN [mm] SPEED TAP CFM [L/s] AIR DELIVERY EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kPa] 0.1 [.02] 0.2 [.05] 0.3 [.07] 0.4 [.10] 0.5 [.12] 0.6 [.15] 0.7 [.17] 0.8 [.19] (-)801SA050314M*A 1/3 [249] 11 x 6 [279 x 15...
Page 9 - OPTION CODE FOR HIGH ALTITUDE:; HIGH ALTITUDE CONVERSION KITS:; NOT; INDOOR COIL CASINGS
Air Accessories R801S (UF/HZ) Series 9 FILTER RACK FILTER SIZES* INCHES [mm] MODEL RXGF-CB (UPFLOW/ HORIZONTAL) RXGF-CD (UPFLOW) SIDE RETURN R801SA050 12 1 / 4 x 25 [311 x 635] 15 3 / 4 x 25 [400 x 635] R801SA075 15 3 / 4 x 25 [400 x 635] 15 3 / 4 x 25 [400 x 635] R801SA100 19 1 / 4 x 25 [489 x 635]...
Page 10 - GENERAL TERMS OF LIMITED WARRANT Y*
Air Limited Warranty R801S (UF/HZ) Series 10 GENERAL TERMS OF LIMITED WARRANT Y* Rheem will furnish a replacement for any part of this productwhich fails in normal use and service within the applicableperiod stated, in accordance with the terms of the limited warranty. *For complete details of the L...