Page 2 - DO NOT; leave this guide inside of the cover of the water heater, as it may; Notice to Victorian Customers from the
RHEEM AUSTRALIA PTY LTD - ABN 21 098 823 511 1 Alan Street (PO Box 6) Rydalmere NSW 2116 Australia PATENTS This system may be protected by one or more patents or registered designs in the name of Rheem Australia Pty Ltd or Paloma Industries Ltd. TRADEMARKS ® Registered trademark of Rheem Australia P...
Page 3 - CONTENTS
3 CONTENTS EZ-Link System ............................................................................ 3 Dual Installation ........................................................................... 6 Labels ........................................................................................... ...
Page 5 - Two continuous flow water heaters manifolded together with an; must not; be fitted to a water heater as part of a solar
EZ-LINK SYSTEM 5 Notes: Only two continuous flow gas water heaters can be installed with an Ez-Link system. The Ez-Link system will vary the start up sequence of the two water heaters. The two continuous flow water heaters must be of the same model. The performance of two different model water heate...
Page 6 - Dual Installation; plumbing arrangement. The installation must
EZ-LINK SYSTEM 6 Dual Installation The two continuous flow water heaters can be installed side by side with minimal clearance between them. The AGA has approved the installation of two water heaters with an exemption from the 300 mm minimum clearance requirements between flue terminals, as stated in...
Page 7 - Labels; „Label Positioning‟; Temperature Controller; efer to “Installation – Controllers” in the Owner‟s Guide and; Label Positioning
EZ-LINK SYSTEM 7 Labels A warning label (121109) and an AGA approval label (121901) are supplied in the Ez-Link kit. Where the two water heaters are installed close together and the warning label and AGA approval label on the inside face of the right hand water heater cannot be read, it is necessary...
Page 9 - Ez-Link Cable Connection
EZ-LINK SYSTEM 9 Ez-Link Cable Connection The references in steps 5 to 8 are to the: „Control Board M16, 018, 020 models with Ez-Link Connection‟ diagram on page 14, and „Control Board 612, E16, 618, 620 models with Ez-Link Connection‟ diagram on page 15, and „Control Board 024, 027 models with Ez-L...
Page 13 - dip switch settings; Refit the front panel and screws to each water heater.
EZ-LINK SYSTEM 13 1 2 3 4 ON DIP2 OFF ON 1 2 3 4 Water Heater no.2 SK6668-46REV_AD 2/12 Temperature Controller(s) Connected No Temperature Controller(s) DIP SWITCHES - EZ LINK INSTALLATION CONTINUOUS FLOW WATER HEATER 86,87 SERIES, 627 MODELS DIP1 OFF ON 1 2 3 4 1 2 3 4 1 2 3 4 ON ON DIP2 OFF ON 1 2...
Page 14 - Both Water Heaters; DIP; ON; OFF
EZ-LINK SYSTEM 14 1 2 3 4 1 2 3 4 ON OF F ON D IP 1 SW1 SW2 REMOTE CONTROLLER TERMINAL Both Water Heaters Dip Switch 4 in the on (up) position Ez-Link Cable Securecable with cable clamp &screw Controller Cable (one water heater only) Ez-Link Cable Connection E E 874, 876 SERIES 012 - 020 MODELS ...
Page 15 - DIP SWITCH SETTINGS; Ez-link Cable Connection
EZ-LINK SYSTEM 15 1 2 3 4 1 2 3 4 ON OFF ON D IP 1 SW1 SW2 REMOTE CONTROLLER TERMINAL Ez-Link Cable Secure cable withcable clamp & screw Optional Controller Cables(first water heater only) E E EZ-link cable drawn through cable grommet on undersideof each water heater 1 2 3 4 1 2 3 4 ON 1 2 3 4 1...
Page 16 - FF; CABLE; Control Board 024, 027 models with Ez-Link Connection
EZ-LINK SYSTEM 16 EZ-LINK CABLE CONNECTION CONTINUOUS FLOW WATER HEATER 86,87 SERIES, 022,024,027 MODELS 1 2 3 4 O FF ON DI P1 ON 1 2 3 4 EZ-LINK CABLE DIP SWITCH 4 OF DIP1 SET OF DIP SWITCHES IN THE ON (UP) POSITION SECURE CABLE WITH CABLE CLAMP AND SCREW PLUG INEZY-LINKCABLEINTOCONNECTOR Control B...
Page 17 - Control Board 627 models with Ez-Link Connection
EZ-LINK SYSTEM 17 EZ-LINK CABLE CONNECTION CONTINUOUS FLOW WATER HEATER 86,87 SERIES, 627 MODELS SK6668-47 REV_AD2/12 1 2 3 4 OFF ON D IP1 ON 1 2 3 4 (WITH OR WITHOUT CONTROLLER) BOTH WATER HEATERS DIP SWITCH 4 OF DIP1 SET OF DIP SWITCHES IN THE ON (UP) POSITION SECURE CABLE WITH CABLE CLAMP AND SCR...
Page 18 - MANIFOLD INSTALLATION - EZ LINK CONNECTION; Typical Two Unit Manifold with Ez-Link Connection
EZ-LINK SYSTEM 18 Typical Two Unit Manifold with Ez-Link Connection MANIFOLD INSTALLATION - EZ LINK CONNECTION TWO CONTINUOUS FLOW WATER HEATERS - 874, 876 SERIES 012 - 020 & 612 - 620 MODELS 350 eaves, balconies& other projections 300 MIN no minimum distance requirement to return wall &...
Page 22 - This page is intentionally blank.