Page ii 59060-05 A S QLogic Fibre Channel Switch Event Message Guide © 2008 QLogic Corporation. All Rights Reserved Worldwide. First Published: April 2004 QLogic Corporation, 26650 Aliso Viejo Parkway, Aliso Viejo, CA 92656, (800) 662-4471 or (949) 389-6000 Information furnished in this manual is be...
59060-05 A Page iii Table of Contents 1 Introduction Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Related Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Technical Support . . . ....
Page iv 59060-05 A QLogic Fibre Channel Switch Event Message Guide S Notes
59060-05 A 1-1 1 Introduction This manual describes the alarm messages for QLogic Fibre Channel switches. This manual is organized as follows: Section 1 describes the intended audience, related materials, and technical support. Section 2 describes event logging concepts, including definitions of...
1 – Introduction Technical Support 1-2 59060-05 A S Technical Support Customers should contact their authorized maintenance provider for technical support of their QLogic switch products. QLogic-direct customers may contact QLogic Technical Support; others will be redirected to their authorized main...
1 – Introduction Technical Support 59060-05 A 1-3 A Contact Information Support Headquarters QLogic Corporation4601 Dean Lakes BoulevardShakopee, MN 55379USA QLogic Web Site www.qlogic.com Technical Support Web Site http://support.qlogic.com Technical Support Email [email protected] Technical Train...
59060-05 A 2-1 2 Events and Event Logging Messages originate from the switch, from Enterprise Fabric Suite 2007, or from the QuickTools web applet in response to events that occur in the fabric. This chapter describes the following topics: Understanding Severity Levels Displaying Events using th...
2 – Events and Event Logging Displaying Events using the Event Browser 2-2 59060-05 A S Displaying Events using the Event Browser Both Enterprise Fabric Suite 2007 and QuickTools have an event browser that displays a list of events generated by the switches in the fabric and by the applications them...
2 – Events and Event Logging Displaying the Events Using the Command Line Interface 59060-05 A 2-3 A In the CLI, each message has the following format: [ordinal][time_stamp][severity][source][message_ID][message_text] Here is a sample of an informative-level message from the Switch source: [1][Wed M...
2 – Events and Event Logging Configuring the Event Log 2-4 59060-05 A S Configuring the Event Log You can customize what events are recorded in the switch event log using the Set Log command. With the Set Log command, you can filter the events to be recorded by component, specific ports, and severit...
2 – Events and Event Logging Configuring Port Alarm Thresholds 59060-05 A 2-5 A Configuring Port Alarm Thresholds You can configure the switch to generate alarms for selected events. Configuring an alarm involves choosing an event type, rising and falling triggers, a sample window, and finally enabl...
59060-05 A 3-1 3 Event Messages This section lists event messages from the command line interface and Enterprise Fabric Suite 2007 in message ID sequence by the following severity levels: Fault Events Alarm Events Critical Events Warning Events Informative Events You can look up a message ...
3 – Event Messages Alarm Events 3-4 59060-05 A S Alarm Events An alarm event requires action before you can proceed any further. The following lists each alarm event ID numbers and message displayed, and provides a description of the meaning of the message and recommended action to take. (A1000.000F...
3 – Event Messages Alarm Events 59060-05 A 3-5 A (A1003.0010) (Segmenting, zoneset zone_set_name not defined) Meaning: In non-interop mode, there is a conflict in the zoning configuration, causing the Inter-Switch Link (ISL) to isolate. The zone set is not found within the local zoning data base whi...
3 – Event Messages Alarm Events 3-8 59060-05 A S (A1003.002A) (No response received from switch with domain ID domain_ID) Meaning: A Staged Fabric Configuration (SFC) frame was sent to the switch given by domain_ID , but a response was not received. Action: Check the status of the remote switch at t...
3 – Event Messages Alarm Events 3-10 59060-05 A S (A1003.0038) (Merge failed, Total zones in zonesets limit would be exceeded.) Meaning: A fabric merge failed because the total number of zones in zone sets exceeds the zoning database limit. Action: Remove zones either from the local switch or the re...
3 – Event Messages Alarm Events 59060-05 A 3-11 A (A1003.0040) (Zone Member type member_type unsupported.) Meaning: An invalid zone member type was discovered in a zone. ACL hard zone membership must be defined by domain_ID and port number. Action: Correct the member type. (A1003.0041) (Zoning objec...
3 – Event Messages Alarm Events 3-12 59060-05 A S (A1003.004F) (No Zone Merge Response) Meaning: A merge request was sent out to all switches in the fabric but a response was not received from at least one switch. Action: Check other switches in fabric to determine why a response was not sent. (A100...
3 – Event Messages Alarm Events 59060-05 A 3-13 A (A1003.0058) (Active ZoneSet zone_set no longer in database, please deactivate zoneset if not already in progress or fabric will be inconsistent) Meaning: A zone set with the same name as the current active zone set no longer resides in the zoning da...
3 – Event Messages Alarm Events 3-14 59060-05 A S (A1003.0069) (Failing remote zoning configuration, invalid zone data received) Meaning: Zoning activation failed because the switch detected invalid zoning data that is not supported in the local interop mode. Action: Check your zoning configuration ...
3 – Event Messages Alarm Events 59060-05 A 3-15 A (A1004.000C) (Eport Isolating due to Domain ID Locked, Domain ID unavailable) Meaning: An E_Port isolated because the requested domain ID matches another in the fabric, and assigning an alternative is prohibited by the domain ID Lock parameter. Actio...
3 – Event Messages Alarm Events 3-16 59060-05 A S (A1004.0013) (Eport Isolating due to all switches incapable of becoming Principal Switch) Meaning: An E_Port isolated because the principal priority on all switches is set to 254. Action: Configure one of the switches to be the principal switch by ch...
3 – Event Messages Alarm Events 59060-05 A 3-17 A (A1004.0026) (Configured Domain ID domain_ID not available and Domain ID is locked on this switch) Meaning: An attempt was made to connect a switch to a fabric with a conflicting domain ID, and the domain ID could not be reassigned. Action: Change th...
3 – Event Messages Alarm Events 3-20 59060-05 A S (A1004.0049) (Eport Isolating due to Remote inactive) Meaning: The remote switch is unresponsive, and the link has not been brought up. The port will be isolated because the remote switch failed to respond. Action: Investigate the remote switch for c...
3 – Event Messages Alarm Events 59060-05 A 3-21 A (A1004.0056) (Blade compromised due to internal data link failure (SET)) Meaning: An I/O blade has been compromised due to failure of its internal data link to the CPU blade. Action: Contact your authorized maintenance provider. (A1004.0057) (Blade n...
3 – Event Messages Alarm Events 3-22 59060-05 A S (A1005.000E) (Configuration error, can't extend credit on loop capable ports. Extended credit not granted for port: port_number) Meaning: Loop ports cannot borrow credits from the credit pool. Action: Change the port type to G_Port or F_Port. (A1005....
3 – Event Messages Alarm Events 3-24 59060-05 A S (A1005.0042) (Target device port_address attached to port port_number with IOStreamGuard Enabled) Meaning: The target device is attached to a port with IO StreamGuard enabled. Action: Disable I/O StreamGuard on the port. (A1005.0045) (Configured port...
3 – Event Messages Alarm Events 59060-05 A 3-27 A (A1005.005E) (Canceling Services edit mode as a result of a CPU switchover) Meaning: A CPU blade switchover occurred while a services edit session was in progress. The edit session was canceled. Action: Reopen the services edit session. (A1005.005F) ...
3 – Event Messages Alarm Events 59060-05 A 3-29 A (A1005.006D) (Unable to synchronize with NTP server) Meaning: The switch was unable to synchronize its time clock with the Network Time Protocol (NTP) server. Action: Confirm that the NTP service and NTP client are enabled. Confirm that the NTP serve...
3 – Event Messages Alarm Events 59060-05 A 3-31 A (A1005.0099) (Canceling IPsec edit mode as a result of a CPU switchover) Meaning: A CPU switchover occurred while an Ipsec Edit session was in progress. The edit session was canceled. Action: Open another Ipsec Edit session. (A1005.0101) (ipv6: dupli...
3 – Event Messages Alarm Events 3-32 59060-05 A S (A1006.0006) (Zoning conflict, device_WWN and device_WWN do not share an ACL hard zone, but device_WWN share a soft zone) Meaning: The named zone members cannot communicate because they are members of different ACL hard zones. Action: Place both zone...
3 – Event Messages Alarm Events 3-34 59060-05 A S (A1007.000E) (Security: Auth challenge received from WWN port_WWN, not Authorized to join) Meaning: A challenge authentication frame was received from a remote switch, but the local switch does not have an entry for itself within the active security ...
3 – Event Messages Alarm Events 59060-05 A 3-35 A (A1007.0013) (Response from address FC_address, lacks authentication, discarding) Meaning: A response received on the indicated port lacked Common Transport (CT) authentication. Action: Verify that the CT security configuration of the management appl...
3 – Event Messages Alarm Events 3-36 59060-05 A S (A1007.0020) (MAX Retry count reached on CHAP Authentication Protocol Reset, failing Authentication) Meaning: A Remote Authentication Dial In Service (RADIUS) server has rejected a RADIUS authentication request. Action: Check the configuration on bot...
3 – Event Messages Alarm Events 59060-05 A 3-37 A (A1007.0026) (Unable to validate Chap Response from device_WWN, possible Chap secret misconfiguration or security breach attempt.) Meaning: A Challenge Handshake Authentication Protocol (CHAP) authentication attempt failed due to failure while compar...
3 – Event Messages Alarm Events 3-38 59060-05 A S (A1007.002B) (Security: Chap session Negotiate Authentication failed) Meaning: The local switch received an authentication negotiate frame which failed processing. Either the payload of the frame did not match the standard layout of the frame or the ...
3 – Event Messages Alarm Events 59060-05 A 3-39 A (A1007.0030) (Security protocol not using chap, unable to authenticate.) Meaning: A Challenge Handshake Authentication Protocol (CHAP) negotiate frame was received that specifies an unsupported Diffie-Helmann (DH) group type. Action: Check the remote...
3 – Event Messages Alarm Events 59060-05 A 3-45 A (A3014.0003) (IOn) (Blade blade_ID set Down due to the configured blade type not matching the installed blade) Meaning: The I/O blade given by blade_ID has isolated because the operational blade type does not match the configured blade type. Action: ...
3 – Event Messages Alarm Events 3-46 59060-05 A S (A6001.0005) (Secondary CPU firmware update in progress, hotreset aborted.) Meaning: The firmware image was being updated on the secondary CPU when a hot reset was attempted. Action: Wait for the firmware update to complete, then retry the hot reset.
3 – Event Messages Critical Events 59060-05 A 3-47 A Critical Events Critical events are events that disrupt the administration or operation of the fabric, but do not require any action before you can proceed. The following lists each critical event and the event id number and message displayed, and...
3 – Event Messages Critical Events 3-50 59060-05 A S (C) (8400.0029) (Switch) (User account_name attempted to log into switch with an incorrect password) Meaning: Invalid user login attempt. (C) (8400.002A) (Switch) (User account_name attempted to log into switch with an incorrect password) Meaning:...
3 – Event Messages Critical Events 59060-05 A 3-51 A (C) (8400.0044) (Switch) (A reset is required since a Power On Self Test (POST) has never run on these ports) Meaning: After upgrading ports, it may be necessary to reset the switch so that the POST can run on the newly licensed ports. (C) (8400.0...
3 – Event Messages Critical Events 3-52 59060-05 A S (C) (8400.0053) (Switch) (The switch WWN is being upgraded) Meaning: The license upgrade was successful. (C) (8400.0054) (Switch) (radius: All RADIUS servers failed to respond) Meaning: None of the Remote Authentication Dial In Service (RADIUS) se...
3 – Event Messages Critical Events 59060-05 A 3-53 A (C) (8400.0060) (Switch) (Warning-Illegal transparent mode configuration, primary and backup cannot be mapped to the same port. Port port_number 's backup mapping has been deleted. Meaning: When mapping TH ports to TF ports, the primary and backup...
3 – Event Messages Critical Events 3-56 59060-05 A S (C) (8600.000B) (PortApp) (Port: port_number) (Link reset (LR) to be performed on port port_number.) Meaning: The port will perform a link reset (LR) due to loss of credit issue. (C) (8600.0013) (PortApp) (Invalid vendor data from media device for...
3 – Event Messages Critical Events 59060-05 A 3-57 A (C) (8600.001A) (PortApp) (Internal port license became available, re-starting downed internal ports) Meaning: A license has become available and ports that had been previously downed to due to unavailable licenses will be restarted. (C) (8600.001...
3 – Event Messages Critical Events 3-58 59060-05 A S (C) (8700.0012) (Eport) (Port: port_number) (Connection failure, fabric limited to two switches) Meaning: The switch cannot be connected to the fabric due to a license restriction. (C) (8700.0013) (Connection failure, fabric limited to two switche...
3 – Event Messages Warning Events 3-60 59060-05 A S Warning Events Warning events are generally not disruptive, but are more significant than Informative-level events. The following lists the Warning events and the event ID number and message displayed, and provides an explanation of the message. (W...
3 – Event Messages Informative Events 3-64 59060-05 A S (W) (8F00:000E) (Link Status status) Meaning: The severity of the link status has changed. The description field will show the reason for link status. Informative Events Informative events are events that occur in the normal activities of a fab...
3 – Event Messages Informative Events 59060-05 A 3-65 A (I) (8200.0201) (mserver) (Rejecting request command:command) Meaning: A fabric zone server command was rejected for the reason detailed in the message. This can be caused by two users attempting to configure the switch or zoning database at th...
3 – Event Messages Informative Events 3-66 59060-05 A S (I) (8300.0010) (Zoning) (Removing all inactive zoning objects) Meaning: All zones that were members of the previously active zone set are being removed from the zoning database. (I) (8400.0001) (Switch) (Modifying configured DomainID domain_ID...
3 – Event Messages Informative Events 59060-05 A 3-67 A (I) (8400.002C) (Switch) (User login session session_ID user account_name has timed out) Meaning: A user login session has ended because of inactivity. (I) (8400.0036) (Switch) (Hotreset not permitted at this time, try again later) Meaning: Con...
3 – Event Messages Informative Events 3-68 59060-05 A S (I) (8400.008C) (CallHome configuration has changed) Meaning: The Call Home service configuration was changed by the administrator. (I) (8400.0097) (DNS lookup for host_name failed) Meaning: The specified host name was not found on the Domain N...
3 – Event Messages Informative Events 59060-05 A 3-69 A (I) (8700.0005) (EPort) (Port: port_number) (Inter-Switch Link (ISL) Offline) Meaning: The specified E_Port is offline, possibly due to a loss of synchronization. (I) (8700.0006) (EPort) (Port: port_number) (Reinitializing port previously isola...
QLogic Manuals
-
QLogic 4100
Manual
-
QLogic SN0054651-00 F
Manual
-
QLogic ISR6152
Manual
-
QLogic 3200
Manual
-
QLogic ISR6250
Manual
-
QLogic QL A 4 0 5 0
Manual
-
QLogic FC HBA CLI
Manual
-
QLogic QLA4050
Manual
-
QLogic 6140
Manual
-
QLogic IB0056101-00 G
Manual
-
QLogic 8100
Manual
-
QLogic ISR6200
Manual
-
QLogic FC2354601-00 A
Manual
- QLogic 9000 Manual
-
QLogic 3000
Manual
-
QLogic 9120
Manual
-
QLogic 8200
Manual
-
QLogic 4 0 6 2 C
Manual
-
QLogic FC0054607-00 A
Manual
-
QLogic 4400
Manual