Page 2 - SAFETY GUIDELINES - DEFINITIONS; stand. This information relates to protecting; IMPORTANT SAFETY INSTRUCTIONS
2- ENG A10244 SAFETY GUIDELINES - DEFINITIONS Indicates an imminent-ly hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situ...
Page 3 - Save these instructions; HAZARD; WARNING: Risk of explosion or fire
3- ENG A10244 IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire...
Page 6 - WARNING: Risk of Burns; WARNING: Risk from Moving Parts
6- ENG A10244 WARNING: Risk of Burns Touching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation. Do not reach ...
Page 7 - WARNING: Risk of Unsafe Operation; WARNING: Risk of Serious Injury or Property Damage; SAVE THESE INSTRUCTIONS
7- ENG A10244 Review and understand all instructions and warnings in this manual. Become familiar with the operation and controls of the air compressor. Keep operating area clear of all persons, pets, and obstacles. Keep children away from the air compressor at all times . Do not operate the product...
Page 8 - CFM; SPECIFICATIONS
8- ENG A10244 GLOSSARY DUTY CYCLE This air compressor pump is capable of running continuously. However, to prolong the life of your air compressor, it is recommended that a 50%-75% average duty cycle be maintained; that is, the air compressor pump should not run more than 30-45 minutes in any given ...
Page 9 - GROUNDING INSTRUCTIONS; Risk of Electrical Shock. In the event of a short circuit,; INSTALLATION; HOW TO SET UP YOUR UNIT; Location of the Air Compressor; ASSEMBLY; Unpacking
9- ENG A10244 GROUNDING INSTRUCTIONS Risk of Electrical Shock. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded. The portable air compressor is equipped with a cord having a ground...
Page 10 - Certain air compressors can be operated on a 15 amp cir-
10- ENG A10244 Extension Cords Using extension cords is not recommended. The use of extension cords will cause voltage to drop resulting in power loss to the motor and overheating.Instead of using an extension cord, increase the working reach of the air hose by attaching another length of hose to it...
Page 11 - Description of Operation; Outlet Pressure Gauge:; OPERATION; Know Your Air Compressor
11- ENG A10244 Description of Operation Become familiar with these controls before operating the unit. On/Auto/Off Switch : Turn this switch "On/Auto" to provide automatic power to the pressure switch and "Off" to remove power at the end of each use. Pressure Switch: The pressure swi...
Page 12 - How to Use Your Unit; Before Starting; Risk of Unsafe Operation. Serious damage may result if; This procedure is required; before; the air compressor is put into service and
12- ENG A10244 Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet. Check Valve: When the air compressor is operating, the check valve is "open", allowing c...
Page 13 - MAINTENANCE; Customer Responsibilities; - more frequent in dusty or humid conditions
13- ENG A10244 How to Start: 1. Turn the On/Auto/Off lever to "On/Auto" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure. 2. Pull the regulator knob out and turn clockwise to increase pressure. When the desired pressure is reached push k...
Page 14 - To Drain Tank; pressure is approximately 20 psi. Release safety valve ring.; To Check Safety Valve; operate smoothly, it must be replaced with the same type of valve.; Air Filter Inspection and Replacement; intake and exhaust valves.
14- ENG A10244 NOTE: See "Operation" section for the location of controls. To Drain Tank 1. Set the On/Auto/Off lever to "Off" and unplug unit.2. Pull the regulator knob out and turn counterclockwise to set the outlet pressure to zero. 3. Remove the air tool or accessory.4. Pull ring...
Page 15 - SERVICE AND ADJUSTMENTS; To Replace or Clean Check Valve; Note; Risk of Unsafe Operation. Unit cycles automatically when
15- ENG A10244 SERVICE AND ADJUSTMENTS To Replace or Clean Check Valve 1. Release all air pressure from air tank. See "To Drain Tank" in the "Maintenance" section. 2. Set the On/Auto/Off lever to "Off" and unplug unit.3. Using an adjustable wrench loosen outlet tube nut at ai...
Page 16 - To Replace Regulator; connect from the regulator.; NOTE
16- ENG A10244 To Replace Regulator 1. Release all air pressure from air tank. See "To Drain Tank" in the "Maintenance" section. 2. Set the On/Auto/Off lever to "Off" and unplug unit.3. Using an adjustable wrench remove the outlet pressure gauge and quick connect from the reg...
Page 17 - STORAGE; scheduled maintenance as necessary.; Risk of Bursting. Water will condense in the air tank. If; After the water has been drained, close the drain or drain valve.
17- ENG A10244 STORAGE Before you store the air compressor, make sure you do the following:1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary. 2. Set the On/Auto/Off lever to "Off" and unplug unit.3. Turn the regulator counterclo...
Page 18 - TROUBLESHOOTING; Check valve seat damaged.
18- ENG A10244 TROUBLESHOOTING Risk of Unsafe Operation. Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source ...
Page 19 - Adjust the regulated
19- ENG A10244 PROBLEM CAUSE CORRECTION It is normal for "some" pressure drop to occur. If there is an excessive amount of pressure drop when the accessory is used, adjust the regulator following the instructions in the "Description of Operation" paragraph in the "Operation" ...
Page 21 - NOTES
Page 22 - LIMITED WARRANTY
22- ENG A10244 LIMITED WARRANTY PORTER-CABLE CORPORATION warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship. Products covered under this warranty include air compressors, air tools, service parts, pressure washers, and g...