Page 2 - PFAFF 2; Contents; Page

PFAFF 2 Contents Checking and adjustment aid ..................................................................................... 3 1 Preliminary adjustment of the needle height ............................................................. 4 2 Zeroing the feed motion ..................................

Page 4 - Checking and adjustment aid; required needle bar positions very precisely.

PFAFF 3 Adjustment hole 1 = 0.6 mm past top dead center of the needle bar (0.6 past t.d.c.). Adjustment hole 3 = 0.6 mm past the bottom dead center of the needle bar (0.6 past b.d.c). Adjustment hole 4 = 1.8 mm past the bottom dead center of the needle bar (needle rise position). Adjustment hole 5 =...

Page 5 - PFAFF; Preliminary adjustment of needle height; Requirement

4 PFAFF 1 Preliminary adjustment of needle height Requirement With the needle bar at b.d.c. there must be a clearance of 16.5 mm between needle holder and needle plate. 2 1 ● Move needle bar 1 (screw 2 ) according to the requirement. Make sure that, when looking in the feed direction, the needle ret...