Panasonic RS-232C - Manuals
Panasonic RS-232C – Manual in PDF format online.
Manuals:
Manual Panasonic RS-232C
Summary
2/49 Using the Serial Terminal 1. Basic Format Transmission from the computer begins with STX, then the command, parameter and ETX are sent in this order. Add parameters according to the details of control. Basic control command (without parameter) Start (STX) Command End (ETX) 1 byte 3 bytes 1 byte...
3/49 2. Basic Control Command Explanatory notes ○ : Yes (Enable) × : No (Disable) △ : Case by case (Refer to the note.) 2.1. Power ON (Lamp ON) Hexadecimal 02h 50h 4Fh 4Eh 03h Character P O N Response (Callback) In the period when the command can be accepted (This command in power-on condition is in...
4/49 2.5. FREEZE Hexadecimal 02h 4Fh 46h 5Ah 3Ah *1 03h Character O F Z : *2 Parameters (*1, *2) FREEZE OFF FREEZE ON Hexadecimal 30h 31h Character 0 1 Response (Callback) In the period when the command can be accepted Hexadecimal 02h 4Fh 46h 5Ah 3Ah *1 03h Character O F Z : *2 Acceptability SECURIT...