Page 2 - Contents; Before using the device
2 Contents Before using the device Introduction ................................................................................................... 3Intended use .................................................................................................. 3Important safety instructions............
Page 4 - Important safety instructions
4 Important safety instructions Read all the information in the instruction manual and any other literature included in the box before using the device. When using an electrical product, especially when children are present, basic safety precautions should always be followed including the following:...
Page 5 - been used on average for more than 60 days, replace it with a new one.
5 Important safety instructions EN • Use only original OMRON AC adapter. Use of unsupported AC adapter may damage the device. • Do not operate the device with a damaged power cord or plug.• Keep the power cord away from heated surfaces.• Read and follow the “Important information regarding Electro M...
Page 6 - the power while nebulising.; General Safety Precautions:; are no problems. In particular, be sure to check the following:; Save these instructions for future reference.
6 Important safety instructions • Do not block the slit between the cap and the inhalation air inlet.• Do not use a microwave oven or hair dryer to dry the nebulising parts.• Approved for human use only.• If the device is used continuously, the service life of the device may be shortened.• Limit use...
Page 8 - Accessories; TM
8 1. Know your unit Accessories Compressor Nebuliser Model NE-C801 • Instruction Manual• Mode d’emploi• Gebrauchsanweisung• Manuale di istruzioni• Manual de instrucciones• Gebruiksaanwijzing• TM TM EN FR DE IT ES NL AR RU IM-NE-C801S-E-03-11/2011 9487399-6C Spare Air Filters × 5 AC adapter Storage B...
Page 9 - Guide to using the device; How the nebuliser kit works; Operating instructions
9 EN 2. Guide to using the device Preparing the Nebuliser for Use - Section 3 (page 10-13) Warning: Clean and disinfect the nebuliser kit, mouthpiece and nosepiece or masks before using them for the first time after purchase, or if the device has not been used for a long period of time, or if more t...
Page 10 - Make sure that the power switch is turned off.
10 3. Preparing the nebuliser for use Warning: Clean and disinfect the nebuliser kit, mouthpiece and nosepiece or masks before using them for the first time after purchase, if the device has not been used for a long period of time, or if more than one person uses the same device. For directions on c...
Page 11 - Preparing the nebuliser for use; Adding medication and assembling the parts
11 3. Preparing the nebuliser for use EN 3.2 Adding medication and assembling the parts 1. Remove the mouthpiece and cap from the nebuliser kit. 2. Remove the inhalation top from the medication tank. 1) Rotate the inhalation top anti-clockwise. 2) Lift the inhalation top out of the medication tank. ...
Page 12 - Attaching the mouthpiece
12 3. Preparing the nebuliser for use 6. Attach the desired inhalation attachment, as described below. Attaching the mouthpiece 1) Attach the cap to the inhalation air inlet. 2) Attach the mouthpiece to the inhalation top. Attaching the nosepiece 1) Attach the cap to the inhalation air inlet. 2) Att...
Page 13 - connector on the compressor.
13 3. Preparing the nebuliser for use EN 7. Attach the air tube. 1) Twist the air tube plug slightly and push it firmly into the air tube connector on the compressor. 2) Twist the air tube plug slightly and push it firmly into the air tube connector on the medication tank. Notes: • Make sure that th...
Page 14 - Do not cover the compressor with a blanket or towel etc., during use.
14 4. Taking medication 1. Hold the nebuliser kit as indicated on the right. Caution: Do not tilt the nebuliser kit at an angle of greater than 45° in all direction. Medication may flow into the mouth. 2. Press the power switch to the on ( ) position. The compressor starts and nebulisation starts. N...
Page 16 - Care and maintenance
16 4. Taking medication 4. When treatment is complete, turn the power off. Check that there is no condensation or moisture in the air tube and unplug the device from the power outlet. Warning: Condensation may occur in the air tube. Do not store the air tube while it contains condensation or moistur...
Page 17 - and also for preventing infections.
17 EN 5. Cleaning and daily disinfecting 5.1 Cleaning Following the cleaning instructions after each use will prevent any remaining medication in the tank from drying, resulting in the device not nebulising effectively and also for preventing infections. Warning: Thoroughly rinse the nebuliser kit a...
Page 18 - Cleaning and daily disinfecting; The compressor is not waterproof.; Reassemble the nebuliser kit. Put it in the storage bag.; Disinfecting the nebulising parts; Remove the parts and discard the solution.
18 5. Cleaning and daily disinfecting 7. If the compressor is dirty, wipe it clean with a soft cloth moistened with water or mild detergent. Caution: The compressor is not waterproof. 8. If the outside of the air tube is dirty, wipe it clean with a soft cloth moistened with water or mild detergent. ...
Page 19 - Handling the Vaporiser Head
19 5. Cleaning and daily disinfecting EN Handling the Vaporiser Head The vaporiser head is an important part that is used to vaporise medication.Be sure to observe the following precautions when handling it. Caution: • Always wash the vaporiser head after each use. • Do not use a brush or pin etc., ...
Page 21 - * an example of commercially available disinfectant.
21 5. Cleaning and daily disinfecting EN O: applicable ×: not applicable * an example of commercially available disinfectant. Boiling Alcohol Sodium hypochlorite Quaternary ammonium Chlorhexidine Amphoteric surfactant Disinfecting ethanol Milton* (0.1%) Osvan* (0.1%) Hibitane* (0.5%) Tego* (0.2%) O ...
Page 22 - Maintenance and storage; Benzene
22 6. Maintenance and storage To keep your device in the best condition and protect the device from damage follow these directions: Caution: • Do not leave the device unattended with infants or persons who cannot express their consent. • Do not subject the device or the parts to any strong shocks su...
Page 23 - Changing the air filter; Change the air filter.
23 EN 7. Changing the air filter If the air filter has changed colour, or has been used on average for more than 60 days, replace it with a new one. 1. Pull the air filter cover off the compressor. 2. Change the air filter. 3. Put the air filter cover back in place. Notes: • Use only OMRON air filte...
Page 25 - to those defined in the specifications.; Rating; Class ll equipment, Type B applied part; Read the instruction
25 EN 9. Technical data Notes: • Subject to technical modification without prior notice.• This OMRON product is produced under the strict quality system of OMRON HEALTHCARE Co., Ltd., Japan. • The device may not work if the temperature and voltage conditions are different to those defined in the spe...
Page 26 - Result of cascade impactor measurements for particle size**; drug supplier’s data sheet for further details.; ml maximum; Appropriate Medication; ml minimum - 7ml maximum
26 9. Technical data Technical data for the OMRON NE-C801 Compressor with the OMRON V.V.T. (Virtual Valve Technology) Nebuliser kit: Result of cascade impactor measurements for particle size** * Measured by OMRON HEALTHCARE Co., Ltd.**Independently measured by Prof. Dr. Hiroshi Takano, Department of...
Page 29 - Optional parts and accessories
29 EN 10.Optional parts and accessories Omron V.V.T. Nebuliser Kit N-01 Set Model: C801S-NSET3-E Order No.: 9515573-6 Air Tube (PVC, 100cm) Model: C801S-ATBP-E Order No.: 9515575-2 Mouthpiece Model: C28-3P-E Order No.: 9956273-5 Air Tube (Silicone, 100cm) Model: C28-6-E Order No.: 9956269-7 Nosepiec...
Page 30 - Optional parts and accessories; Made in China; Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS
30 10. Optional parts and accessories Made in China Manufacturer OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPAN EU-representative OMRON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www.omron-healthcare.com Production facility OMRON (DALIAN...